Product description

Safety sensors; Electronic safety sensors; 5-pole connector M12 for individual connection; Simple mounting without additional angle; Universal coding with RFID technology; Frontal and lateral actuation enabled; RFID-technology for needs-based protection a

Product Details

  • EMC rating
    IEC 60947-3
  • Interfering radiation
    IEC 61000-6-4
  • Current, Utilisation category DC13
    0.05 A
  • Current, Utilisation category DC12
    0.05 A
  • Current leakage Ir
    0.5 mA
  • Voltage, Utilisation category DC13
    24 VDC
  • Switching frequency, approx.
    1 Hz
  • Voltage drop Ud, maximum
    2 V
  • Voltage, Utilisation category DC12
    24 VDC
  • Versions
    p-type
  • Required rated short-circuit current to EN 60947-5-1
    100 A
  • Rated operating voltage, maximum
    26.4 VDC
  • Operating current
    150 mA
  • Rated impulse withstand voltage Uimp
    0.8 kV
  • Rated operating voltage
    24 VDC -15% / +10%
  • No-load supply current I0
    100 mA
  • Rated operating voltage, minimum
    20.4 VDC
  • Degree of pollution to VDE 0100
    3
  • Voltage type
    DC (direct current)
  • Overvoltage category
    III
  • Ambient temperature, maximum
    +65 °C
  • Rated insulation voltage Ui
    32 VDC
  • Storage and transport temperature, maximum
    +85 °C
  • Restistance to shock
    30 g / 11 ms
  • Storage and transport temperature, minimum
    -25 °C
  • Resistance to vibrations to EN 60068-2-6
    10 … 55 Hz, amplitude 1 mm
  • Degree of protection
    IP65 to EN 60529, IP67 to EN 60529
  • Height of sensor
    18 mm
  • Ambient temperature, minimum
    -25 °C
  • Width of sensor
    39.2 mm
  • Length of sensor
    29.5 mm
  • Ensured switch distance OFF Sar, lateral
    15 mm
  • Repeat accuracy R R
    0.5 mm
  • Mounting
    A 20 mm screw length usually suffices to mount the sensor. When the mounting plates are used, we recommend 25 mm long screws.
  • Ensured switching distance ON, side
    6 mm
  • Note
    The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current
  • Terminal Connector
    Connector M12, 5-pole, A-coded
  • Ensured switching distance OFF, front
    18 mm
  • Hysteresis (Switch distance), maximum
    2 mm
  • Ensured switching distance ON, front
    10 mm
  • Actuating panels
    lateral, front side
  • Short-circuit recognition
    Yes
  • Safety functions
    Yes
  • Short circuit detection
    Yes
  • Number of poles
    5
  • Reaction time, maximum
    100 ms
  • Duration of risk, maximum
    200 ms
  • Enclosure material
    Plastic, thermoplastic, self-extinguishing
  • Time to readiness, maximum
    2,000 ms
  • Housing construction form
    Block
  • Gross weight
    121 g
  • Active area
    lateral, front
  • Active principle
    RFID
  • Coding level according to ISO 14119
    Low
  • Standards
    IEC 60947-5-3
  • Installation conditions (mechanical)
    not flush
  • general information
    Universal coding

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



RSS260-D-LSTM12-5-0,25M Related Documents

Manufacturer warranty

RSS260-D-LSTM12-5-0,25M Schmersal

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare RSS260-D-LSTM12-5-0,25M with other products

EMC rating

Interfering radiation

Current, Utilisation cate...

Current, Utilisation cate...

Current leakage Ir

Voltage, Utilisation cate...

Switching frequency, appr...

Voltage drop Ud, maximum

Voltage, Utilisation cate...

Versions

Required rated short-circ...

Rated operating voltage, ...

Operating current

Rated impulse withstand v...

Rated operating voltage

No-load supply current I0

Rated operating voltage, ...

Degree of pollution to VD...

Voltage type

Overvoltage category

Ambient temperature, maxi...

Rated insulation voltage ...

Storage and transport tem...

Restistance to shock

Storage and transport tem...

Resistance to vibrations ...

Degree of protection

Height of sensor

Ambient temperature, mini...

Width of sensor

Length of sensor

Ensured switch distance O...

Repeat accuracy R R

Mounting

Ensured switching distanc...

Note

Terminal Connector

Ensured switching distanc...

Hysteresis (Switch distan...

Ensured switching distanc...

Actuating panels

Short-circuit recognition

Safety functions

Short circuit detection

Number of poles

Reaction time, maximum

Duration of risk, maximum

Enclosure material

Time to readiness, maximu...

Housing construction form

Gross weight

Active area

Active principle

Coding level according to...

Standards

Installation conditions (...

general information

Rated operating current (...

Protection rating

Material temperature resi...

Material temperature resi...

Note (Repeat accuracy R)

Number of fail-safe digit...

Diagnostic output

Output current, (fail-saf...

Material temperature resi...

Ensured switch distance O...

Ensured switch distance O...

Switch distance

Number of semi-conductor ...

Number of LEDs

Cascadable

Integral System Diagnosti...

Sensor topology

Current, Utilisation cate...

Switching principle

Switching element

Thermal test current

Voltage, Utilisation cate...

Cable section, maximum

Cable entry

Cable section, minimum

Actuating speed, maximum

Positive break force, min...

positive break travel

Mechanical life, minimum

Number of cable glands

Material of the contacts,...

Latching force

Number of safety contacts

Number of auxiliary conta...

Selected product

RSS260-D-LSTM12-5-0,25M
0 in stock
RSS260-D-LSTM12-5-0,25M
Schmersal

Safety sensors; Electronic safety sensors; 5-pole connector M12 for individual connection; Simple mo...

EMC ratingIEC 60947-3

Interfering radiationIEC 61000-6-4

Current, Utilisation category DC130.05 A

Current, Utilisation category DC120.05 A

Current leakage Ir0.5 mA

Voltage, Utilisation category DC1324 VDC

Switching frequency, approx.1 Hz

Voltage drop Ud, maximum2 V

Voltage, Utilisation category DC1224 VDC

Versionsp-type

Required rated short-circuit current to EN 60947-5-1100 A

Rated operating voltage, maximum26.4 VDC

Operating current150 mA

Rated impulse withstand voltage Uimp0.8 kV

Rated operating voltage24 VDC -15% / +10%

No-load supply current I0100 mA

Rated operating voltage, minimum20.4 VDC

Degree of pollution to VDE 01003

Voltage typeDC (direct current)

Overvoltage categoryIII

Ambient temperature, maximum+65 °C

Rated insulation voltage Ui32 VDC

Storage and transport temperature, maximum+85 °C

Restistance to shock30 g / 11 ms

Storage and transport temperature, minimum-25 °C

Resistance to vibrations to EN 60068-2-610 … 55 Hz, amplitude 1 mm

Degree of protectionIP65 to EN 60529, IP67 to EN...

Height of sensor18 mm

Ambient temperature, minimum-25 °C

Width of sensor39.2 mm

Length of sensor29.5 mm

Ensured switch distance OFF Sar, lateral15 mm

Repeat accuracy R R0.5 mm

MountingA 20 mm screw length usually...

Ensured switching distance ON, side6 mm

NoteThe cable section of the int...

Terminal ConnectorConnector M12, 5-pole, A-cod...

Ensured switching distance OFF, front18 mm

Hysteresis (Switch distance), maximum2 mm

Ensured switching distance ON, front10 mm

Actuating panelslateral, front side

Short-circuit recognitionYes

Safety functionsYes

Short circuit detectionYes

Number of poles5

Reaction time, maximum100 ms

Duration of risk, maximum200 ms

Enclosure materialPlastic, thermoplastic, self...

Time to readiness, maximum2,000 ms

Housing construction formBlock

Gross weight121 g

Active arealateral, front

Active principleRFID

Coding level according to ISO 14119Low

StandardsIEC 60947-5-3

Installation conditions (mechanical)not flush

general informationUniversal coding

Rated operating current (safety outputs)-

Protection rating-

Material temperature resistance of the cable (in motion), minimum-

Material temperature resistance (long-term), maximum-

Note (Repeat accuracy R)-

Number of fail-safe digital outputs-

Diagnostic output-

Output current, (fail-safe output), maximum-

Material temperature resistance of the cable (at rest), minimum-

Ensured switch distance ON Sao-

Ensured switch distance OFF Sar-

Switch distance-

Number of semi-conductor outputs with signaling function-

Number of LEDs-

Cascadable-

Integral System Diagnostics, status-

Sensor topology-

Current, Utilisation category AC-15-

Switching principle-

Switching element-

Thermal test current-

Voltage, Utilisation category AC15-

Cable section, maximum-

Cable entry-

Cable section, minimum-

Actuating speed, maximum-

Positive break force, minimum-

positive break travel-

Mechanical life, minimum-

Number of cable glands-

Material of the contacts, electrical-

Latching force-

Number of safety contacts-

Number of auxiliary contacts-

RSS 36-D-ST
1 in stock
RSS 36-D-ST
Schmersal

Safety sensors; Electronic safety sensors; Universal coding with RFID technology; 1 x connector sock...

EMC ratingIEC 60947-3

Interfering radiationIEC 61000-6-4

Current, Utilisation category DC130.05 A

Current, Utilisation category DC120.05 A

Current leakage Ir0.5 mA

Voltage, Utilisation category DC1324 VDC

Switching frequency, approx.1 Hz

Voltage drop Ud, maximum2 V

Voltage, Utilisation category DC1224 VDC

Versionsp-type

Required rated short-circuit current to EN 60947-5-1100 A

Rated operating voltage, maximum26.4 VDC

Operating current600 mA

Rated impulse withstand voltage Uimp0.8 kV

Rated operating voltage24 VDC −15 % / +10 %

No-load supply current I0100 mA

Rated operating voltage, minimum20.4 VDC

Degree of pollution to VDE 01003

Voltage typeDC (direct current)

Overvoltage categoryIII

Ambient temperature, maximum+70 °C

Rated insulation voltage Ui32 VDC

Storage and transport temperature, maximum+85 °C

Restistance to shock30 g / 11 ms

Storage and transport temperature, minimum-25 °C

Resistance to vibrations to EN 60068-2-610 … 55 Hz, amplitude 1 mm

Degree of protectionIP65 to EN 60529, IP67 to EN...

Height of sensor25 mm

Ambient temperature, minimum-25 °C

Width of sensor106.3 mm

Length of sensor22 mm

Ensured switch distance OFF Sar, lateral-

Repeat accuracy R R0.5 mm

MountingA screw length of 25 mm is s...

Ensured switching distance ON, side-

NoteThe cable section of the int...

Terminal ConnectorConnector M12, 8-pole

Ensured switching distance OFF, front-

Hysteresis (Switch distance), maximum2 mm

Ensured switching distance ON, front-

Actuating panelslateral

Short-circuit recognitionYes

Safety functionsYes

Short circuit detectionYes

Number of poles-

Reaction time, maximum100 ms

Duration of risk, maximum200 ms

Enclosure materialPlastic, glass-fibre reinfor...

Time to readiness, maximum2,000 ms

Housing construction formBlock

Gross weight80 g

Active arealateral

Active principleRFID

Coding level according to ISO 14119Low

StandardsIEC 60947-5-3

Installation conditions (mechanical)not flush

general informationUniversal coding

Rated operating current (safety outputs)250 mA

Protection ratingIII

Material temperature resistance of the cable (in motion), minimum-10 °C

Material temperature resistance (long-term), maximum+105 °C

Note (Repeat accuracy R)Axial offset: The long side ...

Number of fail-safe digital outputs2

Diagnostic outputYes

Output current, (fail-safe output), maximum0.25 A

Material temperature resistance of the cable (at rest), minimum-30 °C

Ensured switch distance ON Sao10 mm

Ensured switch distance OFF Sar20 mm

Switch distance12 mm

Number of semi-conductor outputs with signaling function1

Number of LEDs3

CascadableYes

Integral System Diagnostics, statusYes

Sensor topologySensor for series wiring

Current, Utilisation category AC-15-

Switching principle-

Switching element-

Thermal test current-

Voltage, Utilisation category AC15-

Cable section, maximum-

Cable entry-

Cable section, minimum-

Actuating speed, maximum-

Positive break force, minimum-

positive break travel-

Mechanical life, minimum-

Number of cable glands-

Material of the contacts, electrical-

Latching force-

Number of safety contacts-

Number of auxiliary contacts-

AZ 16-12ZVRK-M20
4 in stock
AZ 16-12ZVRK-M20
Schmersal

Safety switch with separate actuator; 3 cable entries M 20 x 1.5; Large wiring compartment; Thermopl...

EMC rating-

Interfering radiation-

Current, Utilisation category DC134 A

Current, Utilisation category DC12-

Current leakage Ir-

Voltage, Utilisation category DC1324 VDC

Switching frequency, approx.-

Voltage drop Ud, maximum-

Voltage, Utilisation category DC12-

Versions-

Required rated short-circuit current to EN 60947-5-1-

Rated operating voltage, maximum-

Operating current-

Rated impulse withstand voltage Uimp6 kV

Rated operating voltage-

No-load supply current I0-

Rated operating voltage, minimum-

Degree of pollution to VDE 0100-

Voltage type-

Overvoltage category-

Ambient temperature, maximum+80 °C

Rated insulation voltage Ui500 V

Storage and transport temperature, maximum-

Restistance to shock-

Storage and transport temperature, minimum-

Resistance to vibrations to EN 60068-2-6-

Degree of protectionIP67 to EN 60529

Height of sensor90 mm

Ambient temperature, minimum-30 °C

Width of sensor52 mm

Length of sensor30 mm

Ensured switch distance OFF Sar, lateral-

Repeat accuracy R R-

Mounting-

Ensured switching distance ON, side-

Note-

Terminal ConnectorScrew connection

Ensured switching distance OFF, front-

Hysteresis (Switch distance), maximum-

Ensured switching distance ON, front-

Actuating panels-

Short-circuit recognition-

Safety functions-

Short circuit detection-

Number of poles-

Reaction time, maximum-

Duration of risk, maximum-

Enclosure materialPlastic, glass-fibre reinfor...

Time to readiness, maximum-

Housing construction form-

Gross weight115 g

Active area-

Active principle-

Coding level according to ISO 14119Low

Standards-

Installation conditions (mechanical)-

general information-

Rated operating current (safety outputs)-

Protection rating-

Material temperature resistance of the cable (in motion), minimum-

Material temperature resistance (long-term), maximum-

Note (Repeat accuracy R)-

Number of fail-safe digital outputs-

Diagnostic output-

Output current, (fail-safe output), maximum-

Material temperature resistance of the cable (at rest), minimum-

Ensured switch distance ON Sao-

Ensured switch distance OFF Sar-

Switch distance-

Number of semi-conductor outputs with signaling function-

Number of LEDs-

Cascadable-

Integral System Diagnostics, status-

Sensor topology-

Current, Utilisation category AC-154 A

Switching principleCreep circuit element

Switching elementNO contact, NC contact

Thermal test current10 A

Voltage, Utilisation category AC15230 VAC

Cable section, maximum2.5 mm²

Cable entry3 x M20 x 1,5

Cable section, minimum0.25 mm²

Actuating speed, maximum2 m/s

Positive break force, minimum10 N

positive break travel8 mm

Mechanical life, minimum1,000,000 Operations

Number of cable glands3

Material of the contacts, electricalSilver

Latching force30 N

Number of safety contacts2

Number of auxiliary contacts1

About the manufacturer

Schmersal

Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.

Recently viewed products

Relevant products

FAQ

Out if stock but available for backorder.

Safety sensors; Electronic safety sensors; 5-pole connector M12 for individual connection; Simple mounting without additional angle; Universal coding with RFID technology; Frontal and lateral actuation enabled; RFID-technology for needs-based protection a

Similar products from: Electronic Components

What can I help you find today?

Recommended parts