RSS260-I2-SD-ST Schmersal Safety Switches

RSS260-I2-SD-ST on MQ Automation
Schmersal

Part#:RSS260-I2-SD-ST

Alt. Part#:103003603

Manufacturer:Schmersal

Category:Safety Switches

Product Lifecycle:Active

Product description

RSS260-I2-SD-ST Schmersal - Safety sensors; Electronic safety sensors; Repeated individual coding with RFID technology; Coding level "High" according to ISO 14119; 1 x connector plug M8; Frontal and lateral actuation enabled; Max. 31 sensors can be wired in series.; Thermoplastic en

Product Details

  • Interfering radiation
    IEC 61000-6-4
  • EMC rating
    IEC 60947-3
  • Voltage drop Ud, maximum
    2 V
  • Voltage, Utilisation category DC13
    24 VDC
  • Current, Utilisation category DC13
    0.25 A
  • Current leakage Ir
    0.5 mA
  • Current, Utilisation category DC12
    0.25 A
  • Versions
    p-type
  • Voltage, Utilisation category DC12
    24 VDC
  • Switching frequency, approx.
    1 Hz
  • Operating current
    150 mA
  • Required rated short-circuit current to EN 60947-5-1
    100 A
  • Rated operating voltage, minimum
    20.4 VDC
  • Voltage type
    DC (direct current)
  • Rated operating voltage, maximum
    26.4 VDC
  • Rated operating voltage
    24 VDC -15% / +10%
  • Overvoltage category
    III
  • Degree of pollution to VDE 0100
    3
  • Rated impulse withstand voltage Uimp
    0.8 kV
  • No-load supply current I0
    100 mA
  • Rated insulation voltage Ui
    32 VDC
  • Restistance to shock
    30 g / 11 ms
  • Resistance to vibrations to EN 60068-2-6
    10 … 55 Hz, amplitude 1 mm
  • Storage and transport temperature, maximum
    +85 °C
  • Ambient temperature, maximum
    +65 °C
  • Degree of protection
    IP65 to EN 60529, IP67 to EN 60529
  • Ensured switch distance OFF Sar, lateral
    15 mm
  • Ambient temperature, minimum
    -25 °C
  • Length of sensor
    29.5 mm
  • Storage and transport temperature, minimum
    -25 °C
  • Height of sensor
    18 mm
  • Width of sensor
    39.2 mm
  • Note
    The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current
  • Terminal Connector
    Connector M8
  • Switch distance Sn
    front 12 mm, lateral 9 mm
  • Ensured switching distance ON, side
    6 mm
  • Ensured switching distance OFF, front
    18 mm
  • Ensured switching distance ON, front
    10 mm
  • Note (Repeat accuracy R)
    Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum clearance
  • Hysteresis (Switch distance), maximum
    2 mm
  • Actuating panels
    lateral, front side
  • Mounting
    A 20 mm screw length usually suffices to mount the sensor. When the mounting plates are used, we recommend 25 mm long screws.
  • Number of semi-conductor outputs with signaling function
    1
  • Repeat accuracy R R
    0.5 mm
  • Number of Series-wiring of sensors
    31
  • Integral System Diagnostics, status
    Yes
  • Number of fail-safe digital outputs
    2
  • Number of LEDs
    3
  • Short-circuit recognition
    Yes
  • Cascadable
    Yes
  • Safety functions
    Yes
  • Diagnostic output
    Yes
  • Duration of risk, maximum
    200 ms
  • Short circuit detection
    Yes
  • Serial diagnostics
    Yes
  • Reaction time, maximum
    100 ms
  • Time to readiness, maximum
    2,000 ms
  • Enclosure material
    Plastic, thermoplastic, self-extinguishing
  • Housing construction form
    Block
  • Coding level according to ISO 14119
    High
  • general information
    Individual coding, multiple teaching
  • Installation conditions (mechanical)
    not flush
  • Gross weight
    60 g
  • Active area
    lateral, front
  • Standards
    IEC 60947-5-3
  • Sensor topology
    Sensor for series wiring
  • Active principle
    RFID

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


About the product

RSS260-I2-SD-ST Schmersal - Safety sensors; Electronic safety sensors; Repeated individual coding with RFID technology; Coding level "High" according to ISO 14119; 1 x connector plug M8; Frontal and lateral actuation enabled; Max. 31 sensors can be wired in series.; Thermoplastic en



RSS260-I2-SD-ST Related Documents

Manufacturer warranty

RSS260-I2-SD-ST Schmersal

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare RSS260-I2-SD-ST with other products

Interfering radiation

EMC rating

Voltage drop Ud, maximum

Voltage, Utilisation cate...

Current, Utilisation cate...

Current leakage Ir

Current, Utilisation cate...

Versions

Voltage, Utilisation cate...

Switching frequency, appr...

Operating current

Required rated short-circ...

Rated operating voltage, ...

Voltage type

Rated operating voltage, ...

Rated operating voltage

Overvoltage category

Degree of pollution to VD...

Rated impulse withstand v...

No-load supply current I0

Rated insulation voltage ...

Restistance to shock

Resistance to vibrations ...

Storage and transport tem...

Ambient temperature, maxi...

Degree of protection

Ensured switch distance O...

Ambient temperature, mini...

Length of sensor

Storage and transport tem...

Height of sensor

Width of sensor

Note

Terminal Connector

Switch distance Sn

Ensured switching distanc...

Ensured switching distanc...

Ensured switching distanc...

Note (Repeat accuracy R)

Hysteresis (Switch distan...

Actuating panels

Mounting

Number of semi-conductor ...

Repeat accuracy R R

Number of Series-wiring o...

Integral System Diagnosti...

Number of fail-safe digit...

Number of LEDs

Short-circuit recognition

Cascadable

Safety functions

Diagnostic output

Duration of risk, maximum

Short circuit detection

Serial diagnostics

Reaction time, maximum

Time to readiness, maximu...

Enclosure material

Housing construction form

Coding level according to...

general information

Installation conditions (...

Gross weight

Active area

Standards

Sensor topology

Active principle

Rated operating current (...

Protection rating

Material temperature resi...

Material temperature resi...

Output current, (fail-saf...

Material temperature resi...

Ensured switch distance O...

Ensured switch distance O...

Switch distance

Current, Utilisation cate...

Switching principle

Switching element

Thermal test current

Voltage, Utilisation cate...

Cable section, maximum

Cable entry

Cable section, minimum

Actuating speed, maximum

Positive break force, min...

positive break travel

Mechanical life, minimum

Number of cable glands

Material of the contacts,...

Latching force

Number of safety contacts

Number of auxiliary conta...

Selected product

RSS260-I2-SD-ST
0 in stock
RSS260-I2-SD-ST
Schmersal

RSS260-I2-SD-ST Schmersal - Safety sensors; Electronic safety sensors; Repeated individual coding wi...

Interfering radiationIEC 61000-6-4

EMC ratingIEC 60947-3

Voltage drop Ud, maximum2 V

Voltage, Utilisation category DC1324 VDC

Current, Utilisation category DC130.25 A

Current leakage Ir0.5 mA

Current, Utilisation category DC120.25 A

Versionsp-type

Voltage, Utilisation category DC1224 VDC

Switching frequency, approx.1 Hz

Operating current150 mA

Required rated short-circuit current to EN 60947-5-1100 A

Rated operating voltage, minimum20.4 VDC

Voltage typeDC (direct current)

Rated operating voltage, maximum26.4 VDC

Rated operating voltage24 VDC -15% / +10%

Overvoltage categoryIII

Degree of pollution to VDE 01003

Rated impulse withstand voltage Uimp0.8 kV

No-load supply current I0100 mA

Rated insulation voltage Ui32 VDC

Restistance to shock30 g / 11 ms

Resistance to vibrations to EN 60068-2-610 … 55 Hz, amplitude 1 mm

Storage and transport temperature, maximum+85 °C

Ambient temperature, maximum+65 °C

Degree of protectionIP65 to EN 60529, IP67 to EN...

Ensured switch distance OFF Sar, lateral15 mm

Ambient temperature, minimum-25 °C

Length of sensor29.5 mm

Storage and transport temperature, minimum-25 °C

Height of sensor18 mm

Width of sensor39.2 mm

NoteThe cable section of the int...

Terminal ConnectorConnector M8

Switch distance Snfront 12 mm, lateral 9 mm

Ensured switching distance ON, side6 mm

Ensured switching distance OFF, front18 mm

Ensured switching distance ON, front10 mm

Note (Repeat accuracy R)Axial offset: The long side ...

Hysteresis (Switch distance), maximum2 mm

Actuating panelslateral, front side

MountingA 20 mm screw length usually...

Number of semi-conductor outputs with signaling function1

Repeat accuracy R R0.5 mm

Number of Series-wiring of sensors31

Integral System Diagnostics, statusYes

Number of fail-safe digital outputs2

Number of LEDs3

Short-circuit recognitionYes

CascadableYes

Safety functionsYes

Diagnostic outputYes

Duration of risk, maximum200 ms

Short circuit detectionYes

Serial diagnosticsYes

Reaction time, maximum100 ms

Time to readiness, maximum2,000 ms

Enclosure materialPlastic, thermoplastic, self...

Housing construction formBlock

Coding level according to ISO 14119High

general informationIndividual coding, multiple ...

Installation conditions (mechanical)not flush

Gross weight60 g

Active arealateral, front

StandardsIEC 60947-5-3

Sensor topologySensor for series wiring

Active principleRFID

Rated operating current (safety outputs)-

Protection rating-

Material temperature resistance of the cable (in motion), minimum-

Material temperature resistance (long-term), maximum-

Output current, (fail-safe output), maximum-

Material temperature resistance of the cable (at rest), minimum-

Ensured switch distance ON Sao-

Ensured switch distance OFF Sar-

Switch distance-

Current, Utilisation category AC-15-

Switching principle-

Switching element-

Thermal test current-

Voltage, Utilisation category AC15-

Cable section, maximum-

Cable entry-

Cable section, minimum-

Actuating speed, maximum-

Positive break force, minimum-

positive break travel-

Mechanical life, minimum-

Number of cable glands-

Material of the contacts, electrical-

Latching force-

Number of safety contacts-

Number of auxiliary contacts-

RSS 36-D-ST
1 in stock
RSS 36-D-ST
Schmersal

Safety sensors; Electronic safety sensors; Universal coding with RFID technology; 1 x connector sock...

Interfering radiationIEC 61000-6-4

EMC ratingIEC 60947-3

Voltage drop Ud, maximum2 V

Voltage, Utilisation category DC1324 VDC

Current, Utilisation category DC130.05 A

Current leakage Ir0.5 mA

Current, Utilisation category DC120.05 A

Versionsp-type

Voltage, Utilisation category DC1224 VDC

Switching frequency, approx.1 Hz

Operating current600 mA

Required rated short-circuit current to EN 60947-5-1100 A

Rated operating voltage, minimum20.4 VDC

Voltage typeDC (direct current)

Rated operating voltage, maximum26.4 VDC

Rated operating voltage24 VDC −15 % / +10 %

Overvoltage categoryIII

Degree of pollution to VDE 01003

Rated impulse withstand voltage Uimp0.8 kV

No-load supply current I0100 mA

Rated insulation voltage Ui32 VDC

Restistance to shock30 g / 11 ms

Resistance to vibrations to EN 60068-2-610 … 55 Hz, amplitude 1 mm

Storage and transport temperature, maximum+85 °C

Ambient temperature, maximum+70 °C

Degree of protectionIP65 to EN 60529, IP67 to EN...

Ensured switch distance OFF Sar, lateral-

Ambient temperature, minimum-25 °C

Length of sensor22 mm

Storage and transport temperature, minimum-25 °C

Height of sensor25 mm

Width of sensor106.3 mm

NoteThe cable section of the int...

Terminal ConnectorConnector M12, 8-pole

Switch distance Sn-

Ensured switching distance ON, side-

Ensured switching distance OFF, front-

Ensured switching distance ON, front-

Note (Repeat accuracy R)Axial offset: The long side ...

Hysteresis (Switch distance), maximum2 mm

Actuating panelslateral

MountingA screw length of 25 mm is s...

Number of semi-conductor outputs with signaling function1

Repeat accuracy R R0.5 mm

Number of Series-wiring of sensors-

Integral System Diagnostics, statusYes

Number of fail-safe digital outputs2

Number of LEDs3

Short-circuit recognitionYes

CascadableYes

Safety functionsYes

Diagnostic outputYes

Duration of risk, maximum200 ms

Short circuit detectionYes

Serial diagnostics-

Reaction time, maximum100 ms

Time to readiness, maximum2,000 ms

Enclosure materialPlastic, glass-fibre reinfor...

Housing construction formBlock

Coding level according to ISO 14119Low

general informationUniversal coding

Installation conditions (mechanical)not flush

Gross weight80 g

Active arealateral

StandardsIEC 60947-5-3

Sensor topologySensor for series wiring

Active principleRFID

Rated operating current (safety outputs)250 mA

Protection ratingIII

Material temperature resistance of the cable (in motion), minimum-10 °C

Material temperature resistance (long-term), maximum+105 °C

Output current, (fail-safe output), maximum0.25 A

Material temperature resistance of the cable (at rest), minimum-30 °C

Ensured switch distance ON Sao10 mm

Ensured switch distance OFF Sar20 mm

Switch distance12 mm

Current, Utilisation category AC-15-

Switching principle-

Switching element-

Thermal test current-

Voltage, Utilisation category AC15-

Cable section, maximum-

Cable entry-

Cable section, minimum-

Actuating speed, maximum-

Positive break force, minimum-

positive break travel-

Mechanical life, minimum-

Number of cable glands-

Material of the contacts, electrical-

Latching force-

Number of safety contacts-

Number of auxiliary contacts-

AZ 16-12ZVRK-M20
4 in stock
AZ 16-12ZVRK-M20
Schmersal

Safety switch with separate actuator; 3 cable entries M 20 x 1.5; Large wiring compartment; Thermopl...

Interfering radiation-

EMC rating-

Voltage drop Ud, maximum-

Voltage, Utilisation category DC1324 VDC

Current, Utilisation category DC134 A

Current leakage Ir-

Current, Utilisation category DC12-

Versions-

Voltage, Utilisation category DC12-

Switching frequency, approx.-

Operating current-

Required rated short-circuit current to EN 60947-5-1-

Rated operating voltage, minimum-

Voltage type-

Rated operating voltage, maximum-

Rated operating voltage-

Overvoltage category-

Degree of pollution to VDE 0100-

Rated impulse withstand voltage Uimp6 kV

No-load supply current I0-

Rated insulation voltage Ui500 V

Restistance to shock-

Resistance to vibrations to EN 60068-2-6-

Storage and transport temperature, maximum-

Ambient temperature, maximum+80 °C

Degree of protectionIP67 to EN 60529

Ensured switch distance OFF Sar, lateral-

Ambient temperature, minimum-30 °C

Length of sensor30 mm

Storage and transport temperature, minimum-

Height of sensor90 mm

Width of sensor52 mm

Note-

Terminal ConnectorScrew connection

Switch distance Sn-

Ensured switching distance ON, side-

Ensured switching distance OFF, front-

Ensured switching distance ON, front-

Note (Repeat accuracy R)-

Hysteresis (Switch distance), maximum-

Actuating panels-

Mounting-

Number of semi-conductor outputs with signaling function-

Repeat accuracy R R-

Number of Series-wiring of sensors-

Integral System Diagnostics, status-

Number of fail-safe digital outputs-

Number of LEDs-

Short-circuit recognition-

Cascadable-

Safety functions-

Diagnostic output-

Duration of risk, maximum-

Short circuit detection-

Serial diagnostics-

Reaction time, maximum-

Time to readiness, maximum-

Enclosure materialPlastic, glass-fibre reinfor...

Housing construction form-

Coding level according to ISO 14119Low

general information-

Installation conditions (mechanical)-

Gross weight115 g

Active area-

Standards-

Sensor topology-

Active principle-

Rated operating current (safety outputs)-

Protection rating-

Material temperature resistance of the cable (in motion), minimum-

Material temperature resistance (long-term), maximum-

Output current, (fail-safe output), maximum-

Material temperature resistance of the cable (at rest), minimum-

Ensured switch distance ON Sao-

Ensured switch distance OFF Sar-

Switch distance-

Current, Utilisation category AC-154 A

Switching principleCreep circuit element

Switching elementNO contact, NC contact

Thermal test current10 A

Voltage, Utilisation category AC15230 VAC

Cable section, maximum2.5 mm²

Cable entry3 x M20 x 1,5

Cable section, minimum0.25 mm²

Actuating speed, maximum2 m/s

Positive break force, minimum10 N

positive break travel8 mm

Mechanical life, minimum1,000,000 Operations

Number of cable glands3

Material of the contacts, electricalSilver

Latching force30 N

Number of safety contacts2

Number of auxiliary contacts1

About the manufacturer

Schmersal

Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.

Recently viewed products

Relevant products

FAQ

Out if stock but available for backorder.

RSS260-I2-SD-ST Schmersal - Safety sensors; Electronic safety sensors; Repeated individual coding with RFID technology; Coding level "High" according to ISO 14119; 1 x connector plug M8; Frontal and lateral actuation enabled; Max. 31 sensors can be wired in series.; Thermoplastic en

Similar products from: Safety Switches

What can I help you find today?

Recommended parts