RSS16-D-R-CC Schmersal Safety Switches


Part#:RSS16-D-R-CC
Alt. Part#:103004365
Manufacturer:Schmersal
Category:Safety Switches
Product Lifecycle:Active
Product description
RSS16-D-R-CC Schmersal - Safety sensors; Electronic safety sensors; Universal coding with RFID technology; Spring pulley connection; Series-wiring unlimited; with latching; Thermoplastic enclosure; RFID-technology for needs-based protection against tampering; 3 different directio
Product Details
- EMC rating IEC 60947-3
- Interfering radiation IEC 61000-6-4
- Voltage, Utilisation category DC13 24 VDC
- Current, Utilisation category DC12 0.05 A
- Current, Utilisation category DC13 0.05 A
- Current leakage Ir 0.5 mA
- Output current, (fail-safe output), maximum 1 A
- Voltage drop Ud, maximum 2 V
- Voltage type DC (direct current)
- Rated impulse withstand voltage Uimp 0.8 kV
- Overvoltage category III
- Protection rating 0
- Storage and transport temperature, minimum -25 °C
- Ambient temperature, minimum -25 °C
- Ensured switch distance ON Sao 5 mm
- Voltage, Utilisation category DC12 24 VDC
- Versions p-type
- Rated operating current (safety outputs) 1,000 mA
- Required rated short-circuit current to EN 60947-5-1 100 A
- Switching frequency, approx. 1 Hz
- Operating current 50 mA
- Rated operating voltage, maximum 26.4 VDC
- Rated operating voltage, minimum 20.4 VDC
- Rated insulation voltage Ui 32 VDC
- Degree of pollution to VDE 0100 3
- No-load supply current I0 100 mA
- Restistance to shock 30 g / 11 ms
- Storage and transport temperature, maximum +85 °C
- Width of sensor 52 mm
- Ambient temperature, maximum +70 °C
- Degree of protection IP65 to EN 60529, IP67 to EN 60529
- Height of sensor 30 mm
- Note The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current
- Ensured switch distance OFF Sar 30 mm
- Length of sensor 91 mm
- Terminal Connector Spring pulley connection
- Switch distance 15 mm
- Tightening torque of nuts, maximum 2 Nm
- Repeat accuracy R R 0.5 mm
- Mounting 2 x M5, Cylinder head screw
- Hysteresis (Switch distance), maximum 2 mm
- Number of LEDs 2
- Number of fail-safe digital outputs 2
- Actuating panels front side, rear, from head
- Safety functions Yes
- Number of semi-conductor outputs with signaling function 1
- Integral System Diagnostics, status Yes
- Cascadable Yes
- Short-circuit recognition Yes
- Series-wiring Yes
- Short circuit detection Yes
- Reaction time, maximum 100 ms
- Diagnostic output Yes
- Latching Yes
- Gross weight 208.7 g
- Duration of risk, maximum 200 ms
- Time to readiness, maximum 2,000 ms
- Active principle RFID
- Housing construction form Block
- Sensor topology Sensor for series wiring
- Active area lateral, front side, cover-side
- Installation conditions (mechanical) not flush
- Enclosure material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Standards IEC 60947-5-3
- Coding level according to ISO 14119 Low
- general information Universal coding
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
About the product
RSS16-D-R-CC Schmersal - Safety sensors; Electronic safety sensors; Universal coding with RFID technology; Spring pulley connection; Series-wiring unlimited; with latching; Thermoplastic enclosure; RFID-technology for needs-based protection against tampering; 3 different directio
RSS16-D-R-CC Related Documents
Manufacturer warranty
RSS16-D-R-CC Schmersal
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare RSS16-D-R-CC with other products
EMC rating
Interfering radiation
Voltage, Utilisation cate...
Current, Utilisation cate...
Current, Utilisation cate...
Current leakage Ir
Output current, (fail-saf...
Voltage drop Ud, maximum
Voltage type
Rated impulse withstand v...
Overvoltage category
Protection rating
Storage and transport tem...
Ambient temperature, mini...
Ensured switch distance O...
Voltage, Utilisation cate...
Versions
Rated operating current (...
Required rated short-circ...
Switching frequency, appr...
Operating current
Rated operating voltage, ...
Rated operating voltage, ...
Rated insulation voltage ...
Degree of pollution to VD...
No-load supply current I0
Restistance to shock
Storage and transport tem...
Width of sensor
Ambient temperature, maxi...
Degree of protection
Height of sensor
Note
Ensured switch distance O...
Length of sensor
Terminal Connector
Switch distance
Tightening torque of nuts...
Repeat accuracy R R
Mounting
Hysteresis (Switch distan...
Number of LEDs
Number of fail-safe digit...
Actuating panels
Safety functions
Number of semi-conductor ...
Integral System Diagnosti...
Cascadable
Short-circuit recognition
Series-wiring
Short circuit detection
Reaction time, maximum
Diagnostic output
Latching
Gross weight
Duration of risk, maximum
Time to readiness, maximu...
Active principle
Housing construction form
Sensor topology
Active area
Installation conditions (...
Enclosure material
Standards
Coding level according to...
general information
Rated operating voltage
Material temperature resi...
Resistance to vibrations ...
Material temperature resi...
Note (Repeat accuracy R)
Material temperature resi...
Current, Utilisation cate...
Switching principle
Switching element
Thermal test current
Voltage, Utilisation cate...
Cable section, maximum
Cable entry
Cable section, minimum
Actuating speed, maximum
Positive break force, min...
positive break travel
Mechanical life, minimum
Number of cable glands
Material of the contacts,...
Latching force
Number of safety contacts
Number of auxiliary conta...
Selected product

RSS16-D-R-CC
Schmersal
RSS16-D-R-CC Schmersal - Safety sensors; Electronic safety sensors; Universal coding with RFID techn...
EMC ratingIEC 60947-3
Interfering radiationIEC 61000-6-4
Voltage, Utilisation category DC1324 VDC
Current, Utilisation category DC120.05 A
Current, Utilisation category DC130.05 A
Current leakage Ir0.5 mA
Output current, (fail-safe output), maximum1 A
Voltage drop Ud, maximum2 V
Voltage typeDC (direct current)
Rated impulse withstand voltage Uimp0.8 kV
Overvoltage categoryIII
Protection rating0
Storage and transport temperature, minimum-25 °C
Ambient temperature, minimum-25 °C
Ensured switch distance ON Sao5 mm
Voltage, Utilisation category DC1224 VDC
Versionsp-type
Rated operating current (safety outputs)1,000 mA
Required rated short-circuit current to EN 60947-5-1100 A
Switching frequency, approx.1 Hz
Operating current50 mA
Rated operating voltage, maximum26.4 VDC
Rated operating voltage, minimum20.4 VDC
Rated insulation voltage Ui32 VDC
Degree of pollution to VDE 01003
No-load supply current I0100 mA
Restistance to shock30 g / 11 ms
Storage and transport temperature, maximum+85 °C
Width of sensor52 mm
Ambient temperature, maximum+70 °C
Degree of protectionIP65 to EN 60529, IP67 to EN...
Height of sensor30 mm
NoteThe cable section of the int...
Ensured switch distance OFF Sar30 mm
Length of sensor91 mm
Terminal ConnectorSpring pulley connection
Switch distance15 mm
Tightening torque of nuts, maximum2 Nm
Repeat accuracy R R0.5 mm
Mounting2 x M5, Cylinder head screw
Hysteresis (Switch distance), maximum2 mm
Number of LEDs2
Number of fail-safe digital outputs2
Actuating panelsfront side, rear, from head
Safety functionsYes
Number of semi-conductor outputs with signaling function1
Integral System Diagnostics, statusYes
CascadableYes
Short-circuit recognitionYes
Series-wiringYes
Short circuit detectionYes
Reaction time, maximum100 ms
Diagnostic outputYes
LatchingYes
Gross weight208.7 g
Duration of risk, maximum200 ms
Time to readiness, maximum2,000 ms
Active principleRFID
Housing construction formBlock
Sensor topologySensor for series wiring
Active arealateral, front side, cover-s...
Installation conditions (mechanical)not flush
Enclosure materialPlastic, glass-fibre reinfor...
StandardsIEC 60947-5-3
Coding level according to ISO 14119Low
general informationUniversal coding
Rated operating voltage-
Material temperature resistance of the cable (in motion), minimum-
Resistance to vibrations to EN 60068-2-6-
Material temperature resistance (long-term), maximum-
Note (Repeat accuracy R)-
Material temperature resistance of the cable (at rest), minimum-
Current, Utilisation category AC-15-
Switching principle-
Switching element-
Thermal test current-
Voltage, Utilisation category AC15-
Cable section, maximum-
Cable entry-
Cable section, minimum-
Actuating speed, maximum-
Positive break force, minimum-
positive break travel-
Mechanical life, minimum-
Number of cable glands-
Material of the contacts, electrical-
Latching force-
Number of safety contacts-
Number of auxiliary contacts-
About the manufacturer

Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.
Recently viewed products
Relevant products
FAQ
Out if stock but available for backorder.
RSS16-D-R-CC Schmersal - Safety sensors; Electronic safety sensors; Universal coding with RFID technology; Spring pulley connection; Series-wiring unlimited; with latching; Thermoplastic enclosure; RFID-technology for needs-based protection against tampering; 3 different directio
Similar products from: Safety Switches
What can I help you find today?