161496 Euchner Safety Switches

161496 on MQ Automation
Euchner

Part#:161496

Alt. Part#:CTM-LBI-BR-U-ZZ-SA-P-161496

Manufacturer:Euchner

Category:Safety Switches

Product Lifecycle:Active

Product description

161496 Euchner - Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version

Product Details

  • Weight
    0.5732012 lb
  • Series
    CTM-BR
  • Product Class
    Safety System
  • Category
    4
  • PFHD
    4.52 x 10 ⁻⁹
  • Performance Level
    PL e
  • Mission time
    20 y
  • Repeat accuracy R
    10 %
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Input voltage
    0 ... 5 V DC
  • Off-state current Ir
    max.0,25 mA
  • Turn-on time
    max.400 ms
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Risk time according to EN 60947-5-3
    max.200 ms
  • Discrepancy time
    max.10 ms In acc. with EN 60947-5-3
  • Output voltage
    0 ... 1 V DC
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Switching current
    1 ... 150 mA
  • Test-pulse interval
    100 ms
  • Test pulses
    max.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Operating voltage DC
    24 V DC -15% ... +15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Extension of risk time according to EN 60947-5-3
    max.10 ms
  • Safety class
    III
  • Switching load
    DC 24V, UL Class 2 (Alternatively see operating instructions)
  • Solenoid duty cycle
    100 %
  • Connection rating
    3 W
  • Rated insulation voltage Ui
    50 V
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Fusing
    0,7 ... 8 A
  • Current consumption
    max.7 mA Safety inputs Fl1A/Fl1B
  • Overtravel
    2 mm
  • Actuating force
    44 N
  • Locking force Fmax
    1300 N
  • Extraction force
    32 N
  • Locking force FZh
    1000 N
  • Guard locking principle
    BiState
  • Approach speed
    max.20 m/min
  • Connection
    Plug connector M12, 8-pin
  • Switching frequency
    max.0,25 Hz
  • Weight
    0,16 kg
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Ready delay
    5,5 s
  • Installation orientation
    Any
  • Degree of protection
    IP65/IP67/IP69/IP69K (Screwed tight plug connector/mating component)
  • Ambient temperature
    -20 ... +60 °C
  • Mechanical life
    1 x 10⁶
  • Material
    Fluorinated rubber (FKM)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 161496 on MQ Automation is $613.05. Order now.


About the product

Series connection possible;Bistable guard locking;Category 4 / PL e according to EN ISO 13849-1;Actuation/extension/retention force: 35/30/15 N;Plug connector M12, 8-pin;Unicode;Hygienic version


Manufacturer warranty

161496 Euchner

$613.05

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$613.05

$613.05 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 161496 with other products

Weight

Series

Product Class

Category

PFHD

Performance Level

Mission time

Repeat accuracy R

For the approval acc. to UL the following applies

Input voltage

Off-state current Ir

Turn-on time

Utilization category acc. to EN 60947-5-2

Risk time according to EN 60947-5-3

Discrepancy time

Output voltage

Type of output

Switching current

Test-pulse interval

Test pulses

Operating voltage DC

Degree of contamination (external, according to EN 60947-1)

Extension of risk time according to EN 60947-5-3

Safety class

Switching load

Solenoid duty cycle

Connection rating

Rated insulation voltage Ui

Rated impulse withstand voltage Uimp

Fusing

Current consumption

Overtravel

Actuating force

Locking force Fmax

Extraction force

Locking force FZh

Guard locking principle

Approach speed

Connection

Switching frequency

Weight

Shock and vibration resistance

Ready delay

Installation orientation

Degree of protection

Ambient temperature

Mechanical life

Material

Mission time

PFHD

Category

Performance Level

For the approval acc. to UL the following applies

Additional feature

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Switching current

Type of output

Switching load

Risk time according to EN 60947-5-3

Safety class

Degree of contamination (external, according to EN 60947-1)

Solenoid duty cycle

EMC protection requirements

Rated impulse withstand voltage Uimp

Rated insulation voltage Ui

Connection rating

Fusing

Solenoid operating voltage DC

Operating voltage DC

Utilization category acc. to EN 60947-5-2

Test pulses

Test-pulse interval

Actuating force

Extension of risk time according to EN 60947-5-3 per device

Current consumption

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Connection

Locking force FZh

Guard locking principle

Mechanical life

Ambient temperature

Degree of protection

Switching frequency

Weight

Ready delay

Installation orientation

Shock and vibration resistance

Housing material

B10D

Mission time

PFHD

Performance Level

Category

For the approval acc. to UL the following applies

Version

Operating current

Switching element

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Safety class

Turn-on time

Switching load

EMC protection requirements

Output voltage

Degree of contamination (external, according to EN 60947-1)

Rated insulation voltage Ui

Rated impulse withstand voltage Uimp

Connection rating

Utilization category acc. to EN 60947-5-2

Fusing

Current consumption

Operating voltage DC

Overtravel

Test-pulse interval

Ambient temperature

Extraction force

Test pulses

Actuating force

Installation orientation

Mechanical life

Shock and vibration resistance

Housing material

Approach speed

Degree of protection

Switching frequency

Weight

Ready delay

Connection

Selected product

161496
0 in stock
161496
Euchner

161496 Euchner - Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version

Weight0.5732012 lb

SeriesCTM-BR

Product ClassSafety System

Category4

PFHD4.52 x 10 ⁻⁹

Performance LevelPL e

Mission time20 y

Repeat accuracy R10 %

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

Input voltage0 ... 5 V DC

Off-state current Irmax.0,25 mA

Turn-on timemax.400 ms

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Risk time according to EN 60947-5-3max.200 ms

Discrepancy timemax.10 ms In acc. with EN 60947-5-3

Output voltage0 ... 1 V DC

Type of output2 semiconductor outputs, p-switching, short circuit-proof

Switching current1 ... 150 mA

Test-pulse interval100 ms

Test pulsesmax.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Operating voltage DC24 V DC -15% ... +15% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Degree of contamination (external, according to EN 60947-1)3

Extension of risk time according to EN 60947-5-3max.10 ms

Safety classIII

Switching loadDC 24V, UL Class 2 (Alternatively see operating instructions)

Solenoid duty cycle100 %

Connection rating3 W

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Fusing0,7 ... 8 A

Current consumptionmax.7 mA Safety inputs Fl1A/Fl1B

Overtravel2 mm

Actuating force44 N

Locking force Fmax1300 N

Extraction force32 N

Locking force FZh1000 N

Guard locking principleBiState

Approach speedmax.20 m/min

ConnectionPlug connector M12, 8-pin

Switching frequencymax.0,25 Hz

Weight0,16 kg

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ready delay5,5 s

Installation orientationAny

Degree of protectionIP65/IP67/IP69/IP69K (Screwed tight plug connector/mating component)

Ambient temperature-20 ... +60 °C

Mechanical life1 x 10⁶

MaterialFluorinated rubber (FKM)

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Locking force FZh-

Guard locking principle-

Mechanical life-

Ambient temperature-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Installation orientation-

Shock and vibration resistance-

Housing material-

B10D-

Mission time-

PFHD-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Fusing-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Ambient temperature-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Mechanical life-

Shock and vibration resistance-

Housing material-

Approach speed-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Connection-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Category-

PFHD-

Performance Level-

Mission time-

Repeat accuracy R-

For the approval acc. to UL the following applies-

Input voltage-

Off-state current Ir-

Turn-on time-

Utilization category acc. to EN 60947-5-2-

Risk time according to EN 60947-5-3-

Discrepancy time-

Output voltage-

Type of output-

Switching current-

Test-pulse interval-

Test pulses-

Operating voltage DC-

Degree of contamination (external, according to EN 60947-1)-

Extension of risk time according to EN 60947-5-3-

Safety class-

Switching load-

Solenoid duty cycle-

Connection rating-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Fusing-

Current consumption-

Overtravel-

Actuating force-

Locking force Fmax-

Extraction force-

Locking force FZh-

Guard locking principle-

Approach speed-

Connection-

Switching frequency-

Weight-

Shock and vibration resistance-

Ready delay-

Installation orientation-

Degree of protection-

Ambient temperature-

Mechanical life-

Material-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

Additional featureEscape release actuated by pushing

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN IEC 60947-5-3

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-proof

Switching load24V DC, class 2 (Alternatively see operating instructions)

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Operating voltage DC24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Test pulsesmax.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumption40 mA

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Connection2 plug connectors M12, 5 and 8-pin

Locking force FZh3000 N (Fzh = Fmax/1.3 Depending on the actuator used)

Guard locking principleClosed-circuit current principle

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed tight plug connector/mating component)

Switching frequencymax.0,5 Hz

Weight0,42 kg

Ready delay8 s

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialDie-cast zinc

B10D-

Mission time-

PFHD-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Fusing-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Ambient temperature-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Mechanical life-

Shock and vibration resistance-

Housing material-

Approach speed-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Connection-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Category-

PFHD-

Performance Level-

Mission time-

Repeat accuracy R-

For the approval acc. to UL the following applies-

Input voltage-

Off-state current Ir-

Turn-on time-

Utilization category acc. to EN 60947-5-2-

Risk time according to EN 60947-5-3-

Discrepancy time-

Output voltage-

Type of output-

Switching current-

Test-pulse interval-

Test pulses-

Operating voltage DC-

Degree of contamination (external, according to EN 60947-1)-

Extension of risk time according to EN 60947-5-3-

Safety class-

Switching load-

Solenoid duty cycle-

Connection rating-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Fusing-

Current consumption-

Overtravel-

Actuating force-

Locking force Fmax-

Extraction force-

Locking force FZh-

Guard locking principle-

Approach speed-

Connection-

Switching frequency-

Weight-

Shock and vibration resistance-

Ready delay-

Installation orientation-

Degree of protection-

Ambient temperature-

Mechanical life-

Material-

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Locking force FZh-

Guard locking principle-

Mechanical life-

Ambient temperature-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Installation orientation-

Shock and vibration resistance-

Housing material-

B10D0,13 x 10⁶

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN IEC 60947-5-3

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-switching, short circuit-proof

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternatively see operating instructions)

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Output voltage0 ... 1 V DC

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Fusing0,25 ... 8 A

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Overtravel5 mm

Test-pulse intervalmin.100 ms

Ambient temperature-20 ... +55 °C

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Actuating force10 N

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialFiber glass reinforced thermoplastic

Approach speedmax.20 m/min

Degree of protectionIP65 (Screwed tight plug connector/mating component)

Switching frequencymax.0,5 Hz

Weight1,25 kg

Ready delaymax.1 s

Connection2 plug connectors M12, 5-pin

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 161496?
The price of 161496 on MQ Automation is $613.05. Order now.

Out if stock but available for backorder.

161496 Euchner - Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version

Similar products from: Safety Switches

What can I help you find today?

Recommended parts