162926 Euchner Electronic Components

162926 on MQ Automation
Euchner

Part#:162926

Manufacturer:Euchner

Category:Electronic Components

Product Lifecycle:Active

In-stock parts: 1

Jan 19, 2025

MGBS-P-I-AP, emergency stop, 2 x M12

About the manufacturer: Euchner is one of the manufacturers that offers Electronic Components that you can order at MQ Automation site. As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Check out the 162926 Euchner price in the box on the right side or send a quick quote.

Product Details

  • B10D
    0,13 x 10⁶
  • Mission time
    20 y
  • PFHD
    4.1 x 10 ⁻⁹
  • Performance Level
    PL e
  • Category
    4
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Version
    Emergency stop
  • Operating current
    1 ... 100 mA
  • Switching element
    2 pos. driven NC
  • Repeat accuracy R
    10 %
  • Detent mechanism
    Snap-in bolt
  • Discrepancy time
    max.10 ms In acc. with EN IEC 60947-5-3
  • Off-state current Ir
    max.0,25 mA
  • Operating voltage
    5 ... 24 V
  • Switching current
    1 ... 150 mA
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Safety class
    III
  • Turn-on time
    max.400 ms
  • Switching load
    24V DC, class 2 (Alternatively see operating instructions)
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Output voltage
    0 ... 1 V DC
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated insulation voltage Ui
    50 V
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Connection rating
    1 W
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Fusing
    0,25 ... 8 A
  • Current consumption
    40 mA
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Overtravel
    5 mm
  • Test-pulse interval
    min.100 ms
  • Ambient temperature
    -20 ... +55 °C
  • Extraction force
    20 N
  • Test pulses
    max.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Actuating force
    10 N
  • Installation orientation
    Door hinge DIN right
  • Mechanical life
    1 x 10⁶
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Housing material
    Fiber glass reinforced thermoplastic
  • Approach speed
    max.20 m/min
  • Degree of protection
    IP65 (Screwed tight plug connector/mating component)
  • Switching frequency
    max.0,5 Hz
  • Weight
    1,25 kg
  • Ready delay
    max.1 s
  • Connection
    2 plug connectors M12, 5-pin

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price within minutes.

Stock:

1

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts