161481 Euchner Safety Accessories

161481 on MQ Automation
Euchner

Part#:161481

Alt. Part#:MGB-L2B-PNA-R-161481

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

161481 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 5 control elements, 7/8" and M12 plugs

Product Details

  • Weight
    8.377556 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Mission time
    20
  • Diagnostic Coverage (DC)
    99
  • PFHD
    4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)
  • B10D
    0,13 x 10⁶
  • Performance Level
    PL e
  • Category
    4
  • Switching element
    2 pos. driven NC
  • Version
    Emergency stop illuminated
  • Assured release distance Sar
    max.65 mm
  • Product version number
    V3.30.10
  • Assignment diagram
    B1
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Fusing
    min.1 A Slow blow
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Transponder coding
    Unicode
  • Safety class
    III
  • Rated insulation voltage Ui
    75 V
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Current consumption
    max.500 mA
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Guard locking principle
    Open-circuit current principle
  • Locking force FZh
    2000 N
  • Connection
    M12 D-coded, screened (X4 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Reaction time
    max.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Installation orientation
    Door hinge DIN right
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Weight
    3,1 kg
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz
  • Ambient temperature
    -20 ... 55 °C
  • Degree of protection
    IP54

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 161481 on MQ Automation is $3,376.43. Order now.


About the product

Guard locking with guard lock monitoring;Emergency stop according to ISO 13850, illuminated;4 illuminated pushbuttons;including adhesive labels;Connection via 7/8&quot; and M12 plugs;including terminal plug for stack light (M12, 5-pin);Pre-assembled on mounting plates;Integrated Profinet RT switch;Unicode


Manufacturer warranty

161481 Euchner

$3,376.43

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$3,376.43

$3,376.43 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 161481 with other products

Weight

Series

Product Class

Safety Integrity Level

Mission time

Diagnostic Coverage (DC)

PFHD

B10D

Performance Level

Category

Switching element

Version

Assured release distance Sar

Product version number

Assignment diagram

Bus data protocol

Safety data protocol

Fusing

Auxiliary voltage DC

Operating voltage DC

Transponder coding

Safety class

Rated insulation voltage Ui

Connecting cable

Degree of contamination (external, according to EN 60947-1)

EMC protection requirements

Rated impulse withstand voltage Uimp

Current consumption

Maximum feed-in current in the connection block

Guard locking principle

Locking force FZh

Connection

Reaction time

Shock and vibration resistance

Installation orientation

Housing material

Weight

Mechanical life

Switching frequency

Ambient temperature

Degree of protection

B10D

Mission time

PFHD

Performance Level

Category

For the approval acc. to UL the following applies

Version

Operating current

Switching element

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Safety class

Turn-on time

Switching load

EMC protection requirements

Output voltage

Degree of contamination (external, according to EN 60947-1)

Rated insulation voltage Ui

Rated impulse withstand voltage Uimp

Connection rating

Utilization category acc. to EN 60947-5-2

Fusing

Current consumption

Operating voltage DC

Overtravel

Test-pulse interval

Ambient temperature

Extraction force

Test pulses

Actuating force

Installation orientation

Mechanical life

Shock and vibration resistance

Housing material

Approach speed

Degree of protection

Switching frequency

Weight

Ready delay

Connection

Mission time

PFHD

Category

Performance Level

For the approval acc. to UL the following applies

Additional feature

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Switching current

Type of output

Switching load

Risk time according to EN 60947-5-3

Safety class

Degree of contamination (external, according to EN 60947-1)

Solenoid duty cycle

EMC protection requirements

Rated impulse withstand voltage Uimp

Rated insulation voltage Ui

Connection rating

Fusing

Solenoid operating voltage DC

Operating voltage DC

Utilization category acc. to EN 60947-5-2

Test pulses

Test-pulse interval

Actuating force

Extension of risk time according to EN 60947-5-3 per device

Current consumption

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Connection

Locking force FZh

Guard locking principle

Mechanical life

Ambient temperature

Degree of protection

Switching frequency

Weight

Ready delay

Installation orientation

Shock and vibration resistance

Housing material

Selected product

161481
0 in stock
161481
Euchner

161481 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) ...

Weight8.377556 lb

SeriesSpare parts

Product ClassAccessories

Safety Integrity LevelSIL 3 (EN 62061:2005)

Mission time20

Diagnostic Coverage (DC)99

PFHD4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)

B10D0,13 x 10⁶

Performance LevelPL e

Category4

Switching element2 pos. driven NC

VersionEmergency stop illuminated

Assured release distance Sarmax.65 mm

Product version numberV3.30.10

Assignment diagramB1

Bus data protocolProfinet (IEC 61158 type 10)

Safety data protocolProfisafe (IEC 61784-3-3)

Fusingmin.1 A Slow blow

Auxiliary voltage DC24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)

Operating voltage DC24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))

Transponder codingUnicode

Safety classIII

Rated insulation voltage Ui75 V

Connecting cableProfinet I/O cable, at least cat. 5e

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn accordance with EN 61000-4 and EN 61326-3-1

Rated impulse withstand voltage Uimp0,5 kV

Current consumptionmax.500 mA

Maximum feed-in current in the connection blockmax.4000 mA

Guard locking principleOpen-circuit current principle

Locking force FZh2000 N

ConnectionM12 D-coded, screened (X4 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))

Reaction timemax.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)

Shock and vibration resistanceIn acc. with EN 60947-5-3

Installation orientationDoor hinge DIN right

Housing materialReinforced plastic, die-cast zinc nickel-plated, stainless steel

Weight3,1 kg

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

Ambient temperature-20 ... 55 °C

Degree of protectionIP54

B10D-

Mission time-

PFHD-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Fusing-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Ambient temperature-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Mechanical life-

Shock and vibration resistance-

Housing material-

Approach speed-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Connection-

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Locking force FZh-

Guard locking principle-

Mechanical life-

Ambient temperature-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Installation orientation-

Shock and vibration resistance-

Housing material-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Safety Integrity Level-

Mission time-

Diagnostic Coverage (DC)-

PFHD-

B10D-

Performance Level-

Category-

Switching element-

Version-

Assured release distance Sar-

Product version number-

Assignment diagram-

Bus data protocol-

Safety data protocol-

Fusing-

Auxiliary voltage DC-

Operating voltage DC-

Transponder coding-

Safety class-

Rated insulation voltage Ui-

Connecting cable-

Degree of contamination (external, according to EN 60947-1)-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Current consumption-

Maximum feed-in current in the connection block-

Guard locking principle-

Locking force FZh-

Connection-

Reaction time-

Shock and vibration resistance-

Installation orientation-

Housing material-

Weight-

Mechanical life-

Switching frequency-

Ambient temperature-

Degree of protection-

B10D0,13 x 10⁶

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN IEC 60947-5-3

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-switching, short circuit-proof

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternatively see operating instructions)

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Output voltage0 ... 1 V DC

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Fusing0,25 ... 8 A

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Overtravel5 mm

Test-pulse intervalmin.100 ms

Ambient temperature-20 ... +55 °C

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Actuating force10 N

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialFiber glass reinforced thermoplastic

Approach speedmax.20 m/min

Degree of protectionIP65 (Screwed tight plug connector/mating component)

Switching frequencymax.0,5 Hz

Weight1,25 kg

Ready delaymax.1 s

Connection2 plug connectors M12, 5-pin

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Locking force FZh-

Guard locking principle-

Mechanical life-

Ambient temperature-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Installation orientation-

Shock and vibration resistance-

Housing material-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Safety Integrity Level-

Mission time-

Diagnostic Coverage (DC)-

PFHD-

B10D-

Performance Level-

Category-

Switching element-

Version-

Assured release distance Sar-

Product version number-

Assignment diagram-

Bus data protocol-

Safety data protocol-

Fusing-

Auxiliary voltage DC-

Operating voltage DC-

Transponder coding-

Safety class-

Rated insulation voltage Ui-

Connecting cable-

Degree of contamination (external, according to EN 60947-1)-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Current consumption-

Maximum feed-in current in the connection block-

Guard locking principle-

Locking force FZh-

Connection-

Reaction time-

Shock and vibration resistance-

Installation orientation-

Housing material-

Weight-

Mechanical life-

Switching frequency-

Ambient temperature-

Degree of protection-

B10D-

Mission time-

PFHD-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Fusing-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Ambient temperature-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Mechanical life-

Shock and vibration resistance-

Housing material-

Approach speed-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Connection-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

Additional featureEscape release actuated by pushing

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN IEC 60947-5-3

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-proof

Switching load24V DC, class 2 (Alternatively see operating instructions)

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Operating voltage DC24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Test pulsesmax.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumption40 mA

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Connection2 plug connectors M12, 5 and 8-pin

Locking force FZh3000 N (Fzh = Fmax/1.3 Depending on the actuator used)

Guard locking principleClosed-circuit current principle

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed tight plug connector/mating component)

Switching frequencymax.0,5 Hz

Weight0,42 kg

Ready delay8 s

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialDie-cast zinc

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 161481?
The price of 161481 on MQ Automation is $3,376.43. Order now.

Out if stock but available for backorder.

161481 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 5 control elements, 7/8&quot; and M12 plugs

What can I help you find today?

Recommended parts