136625 Euchner Electronic Components
Part#:136625
Manufacturer:Euchner
Category:Electronic Components
Product Lifecycle:Active
Get a quick Quote!
Transponder-coded safety switch CTP-AP, 2 x M12
About the manufacturer: Euchner is one of the manufacturers that offers Electronic Components that you can order at MQ Automation site. As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Check out the 136625 Euchner price in the box on the right side or send a quick quote.
Product Details
- Mission time 20 y
- PFHD 4.1 x 10 ⁻⁹
- Performance Level PL e
- For the approval acc. to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
- Category 4
- Additional feature Cover without auxiliary release
- Repeat accuracy R 10 %
- Discrepancy time max.10 ms In acc. with EN IEC 60947-5-3
- Off-state current Ir max.0,25 mA
- Turn-on time max.400 ms
- Output voltage UB-1,5 ... UB V DC
- Switching current 1 ... 150 mA
- Switching load 24V DC, class 2 (Alternatively see operating instructions)
- Type of output 2 semiconductor outputs, p-switching, short circuit-proof
- Safety class III
- Degree of contamination (external, according to EN 60947-1) 3
- Solenoid duty cycle 100 %
- EMC protection requirements In acc. with EN IEC 60947-5-3
- Connection rating 6 W
- Rated impulse withstand voltage Uimp 0,5 kV
- Rated insulation voltage Ui 50 V
- Solenoid operating voltage DC 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
- Current consumption 40 mA
- Fusing 0,25 ... 8 A
- Utilization category acc. to EN 60947-5-2 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
- Test pulses max.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
- Operating voltage DC 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
- Test-pulse interval min.100 ms
- Overtravel 5 mm
- Actuating force 10 N
- Locking force FZh 3000 N (Fzh = Fmax/1.3 Depending on the actuator used)
- Extraction force 20 N
- Retention force 20 N
- Locking force Fmax 3900 N
- Guard locking principle Closed-circuit current principle
- Approach speed max.20 m/min
- Installation orientation Any
- Degree of protection IP67/IP69/IP69K (Screwed tight plug connector/mating component)
- Ambient temperature -20 ... +55 °C
- Weight 0,42 kg
- Connection 2 plug connectors M12, 5-pin + pin 5 not used
- Shock and vibration resistance In acc. with EN 60947-5-3
- Switching frequency max.0,5 Hz
- Housing material Die-cast zinc
- Ready delay max.1 s
- Mechanical life 1 x 10⁶
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
What can I help you find today?