Solenoid interlocks; Large wiring compartment; Emergency exit, cover-side; cable entries 4 M 16 x 1.5; Thermoplastic enclosure; Double-insulated; Interlock with protection against incorrect locking.; 130 mm x 90 mm x 30 mm; 6 Contacts; Long life
Product Details
- Current, Utilisation category DC13 2.5 A
- Current, Utilisation category AC-15 4 A
- Voltage, Utilisation category DC13 24 VDC
- Switching frequency 1,000 /h
- Switching principle Creep circuit element
- Voltage, Utilisation category AC15 230 VAC
- Switching element NO contact, NC contact
- Electrical power consumption, maximum 10 W
- Rated impulse withstand voltage Uimp 4 kV
- Required rated short-circuit current to EN 60947-5-1 1,000 A
- Rated control voltage 24 VAC/DC
- Thermal test current 6 A
- Ambient temperature, minimum -25 °C
- Rated insulation voltage Ui 250 V
- Height of sensor 90 mm
- Ambient temperature, maximum +60 °C
- Width of sensor 130 mm
- Degree of protection IP67 to EN 60529
- Cable section, maximum 1 x 1.5 mm²
- Note (Cable section) All indications about the cable section are including the conductor ferrules.
- Cable section, minimum 1 x 0.25 mm²
- Length of sensor 30 mm
- positive break travel 10 mm
- Positive break force, minimum 20 N
- Terminal Connector Screw terminals
- Actuating speed, maximum 2 m/s
- Clamping force in accordance with ISO14119 Fzh 2,000 N
- Actuating play in direction of actuation 5.5 mm
- Latching force 30 N
- Mechanical life, minimum 1,000,000 Operations
- Number of safety contacts 4
- Material of the contacts, electrical Silver
- Active principle electromechanical
- Coding level according to ISO 14119 Low
- Manual release Yes
- Number of auxiliary contacts 2
- Enclosure material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Power to unlock Yes
- Gross weight 432 g
- Emergency exit Yes
- Standards EN 60947-5-1, BG-GS-ET-19
- Number of actuating directions 3
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
AZM 161SK-12/12RKTD-024 Related Documents
Manufacturer warranty
AZM 161SK-12/12RKTD-024 Schmersal
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare AZM 161SK-12/12RKTD-024 with other products
Current, Utilisation category DC13
Current, Utilisation category AC-15
Voltage, Utilisation category DC13
Switching frequency
Switching principle
Voltage, Utilisation category AC15
Switching element
Electrical power consumption, maximum
Rated impulse withstand voltage Uimp
Required rated short-circuit current to EN 60947-5-1
Rated control voltage
Thermal test current
Ambient temperature, minimum
Rated insulation voltage Ui
Height of sensor
Ambient temperature, maximum
Width of sensor
Degree of protection
Cable section, maximum
Note (Cable section)
Cable section, minimum
Length of sensor
positive break travel
Positive break force, minimum
Terminal Connector
Actuating speed, maximum
Clamping force in accordance with ISO14119 Fzh
Actuating play in direction of actuation
Latching force
Mechanical life, minimum
Number of safety contacts
Material of the contacts, electrical
Active principle
Coding level according to ISO 14119
Manual release
Number of auxiliary contacts
Enclosure material
Power to unlock
Gross weight
Emergency exit
Standards
Number of actuating directions
Current, Utilisation category DC13
Voltage, Utilisation category DC13
Current, Utilisation category AC-15
Switching principle
Switching element
Thermal test current
Ambient temperature, maximum
Voltage, Utilisation category AC15
Degree of protection
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
Ambient temperature, minimum
Height of sensor
Cable section, maximum
Terminal Connector
Length of sensor
Width of sensor
Cable entry
Cable section, minimum
Actuating speed, maximum
Positive break force, minimum
positive break travel
Mechanical life, minimum
Number of cable glands
Coding level according to ISO 14119
Material of the contacts, electrical
Latching force
Number of safety contacts
Gross weight
Enclosure material
Number of auxiliary contacts
Interfering radiation
EMC rating
Current, Utilisation category DC12
Voltage, Utilisation category DC13
Current, Utilisation category DC13
Versions
Voltage drop Ud, maximum
Current leakage Ir
Rated operating current (safety outputs)
Operating current
Required rated short-circuit current to EN 60947-5-1
Rated operating voltage, minimum
Voltage type
Rated operating voltage
No-load supply current I0
Protection rating
Overvoltage category
Restistance to shock
Material temperature resistance of the cable (in motion), minimum
Resistance to vibrations to EN 60068-2-6
Material temperature resistance (long-term), maximum
Degree of protection
Ambient temperature, minimum
Terminal Connector
Note (Repeat accuracy R)
Number of fail-safe digital outputs
Short-circuit recognition
Diagnostic output
Gross weight
Active area
Voltage, Utilisation category DC12
Switching frequency, approx.
Output current, (fail-safe output), maximum
Rated operating voltage, maximum
Degree of pollution to VDE 0100
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Material temperature resistance of the cable (at rest), minimum
Storage and transport temperature, maximum
Storage and transport temperature, minimum
Ambient temperature, maximum
Ensured switch distance ON Sao
Note
Length of sensor
Height of sensor
Width of sensor
Ensured switch distance OFF Sar
Switch distance
Hysteresis (Switch distance), maximum
Repeat accuracy R R
Mounting
Actuating panels
Number of semi-conductor outputs with signaling function
Number of LEDs
Cascadable
Integral System Diagnostics, status
Duration of risk, maximum
Safety functions
Time to readiness, maximum
Reaction time, maximum
Short circuit detection
Enclosure material
Sensor topology
Active principle
Standards
Installation conditions (mechanical)
Coding level according to ISO 14119
general information
Housing construction form
Selected product

AZM 161SK-12/12RKTD-024
Schmersal
Solenoid interlocks; Large wiring compartment; Emergency exit, cover-side; cable entries 4 M 16 x 1....
Current, Utilisation category DC132.5 A
Current, Utilisation category AC-154 A
Voltage, Utilisation category DC1324 VDC
Switching frequency1,000 /h
Switching principleCreep circuit element
Voltage, Utilisation category AC15230 VAC
Switching elementNO contact, NC contact
Electrical power consumption, maximum10 W
Rated impulse withstand voltage Uimp4 kV
Required rated short-circuit current to EN 60947-5-11,000 A
Rated control voltage24 VAC/DC
Thermal test current6 A
Ambient temperature, minimum-25 °C
Rated insulation voltage Ui250 V
Height of sensor90 mm
Ambient temperature, maximum+60 °C
Width of sensor130 mm
Degree of protectionIP67 to EN 60529
Cable section, maximum1 x 1.5 mm²
Note (Cable section)All indications about the cable section are including the conductor ferrules.
Cable section, minimum1 x 0.25 mm²
Length of sensor30 mm
positive break travel10 mm
Positive break force, minimum20 N
Terminal ConnectorScrew terminals
Actuating speed, maximum2 m/s
Clamping force in accordance with ISO14119 Fzh2,000 N
Actuating play in direction of actuation5.5 mm
Latching force30 N
Mechanical life, minimum1,000,000 Operations
Number of safety contacts4
Material of the contacts, electricalSilver
Active principleelectromechanical
Coding level according to ISO 14119Low
Manual releaseYes
Number of auxiliary contacts2
Enclosure materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
Power to unlockYes
Gross weight432 g
Emergency exitYes
StandardsEN 60947-5-1, BG-GS-ET-19
Number of actuating directions3
Current, Utilisation category DC13-
Voltage, Utilisation category DC13-
Current, Utilisation category AC-15-
Switching principle-
Switching element-
Thermal test current-
Ambient temperature, maximum-
Voltage, Utilisation category AC15-
Degree of protection-
Rated insulation voltage Ui-
Rated impulse withstand voltage Uimp-
Ambient temperature, minimum-
Height of sensor-
Cable section, maximum-
Terminal Connector-
Length of sensor-
Width of sensor-
Cable entry-
Cable section, minimum-
Actuating speed, maximum-
Positive break force, minimum-
positive break travel-
Mechanical life, minimum-
Number of cable glands-
Coding level according to ISO 14119-
Material of the contacts, electrical-
Latching force-
Number of safety contacts-
Gross weight-
Enclosure material-
Number of auxiliary contacts-
Interfering radiation-
EMC rating-
Current, Utilisation category DC12-
Voltage, Utilisation category DC13-
Current, Utilisation category DC13-
Versions-
Voltage drop Ud, maximum-
Current leakage Ir-
Rated operating current (safety outputs)-
Operating current-
Required rated short-circuit current to EN 60947-5-1-
Rated operating voltage, minimum-
Voltage type-
Rated operating voltage-
No-load supply current I0-
Protection rating-
Overvoltage category-
Restistance to shock-
Material temperature resistance of the cable (in motion), minimum-
Resistance to vibrations to EN 60068-2-6-
Material temperature resistance (long-term), maximum-
Degree of protection-
Ambient temperature, minimum-
Terminal Connector-
Note (Repeat accuracy R)-
Number of fail-safe digital outputs-
Short-circuit recognition-
Diagnostic output-
Gross weight-
Active area-
Voltage, Utilisation category DC12-
Switching frequency, approx.-
Output current, (fail-safe output), maximum-
Rated operating voltage, maximum-
Degree of pollution to VDE 0100-
Rated impulse withstand voltage Uimp-
Rated insulation voltage Ui-
Material temperature resistance of the cable (at rest), minimum-
Storage and transport temperature, maximum-
Storage and transport temperature, minimum-
Ambient temperature, maximum-
Ensured switch distance ON Sao-
Note-
Length of sensor-
Height of sensor-
Width of sensor-
Ensured switch distance OFF Sar-
Switch distance-
Hysteresis (Switch distance), maximum-
Repeat accuracy R R-
Mounting-
Actuating panels-
Number of semi-conductor outputs with signaling function-
Number of LEDs-
Cascadable-
Integral System Diagnostics, status-
Duration of risk, maximum-
Safety functions-
Time to readiness, maximum-
Reaction time, maximum-
Short circuit detection-
Enclosure material-
Sensor topology-
Active principle-
Standards-
Installation conditions (mechanical)-
Coding level according to ISO 14119-
general information-
Housing construction form-
About the manufacturer

Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.
Recently viewed products
Relevant products
FAQ
Out if stock but available for backorder.
Solenoid interlocks; Large wiring compartment; Emergency exit, cover-side; cable entries 4 M 16 x 1.5; Thermoplastic enclosure; Double-insulated; Interlock with protection against incorrect locking.; 130 mm x 90 mm x 30 mm; 6 Contacts; Long life
Similar products from: Safety Switches
What can I help you find today?