AZM 161SK-12/12K-024 Schmersal Safety Switches


Part#:AZM 161SK-12/12K-024
Alt. Part#:101176503
Manufacturer:Schmersal
Category:Safety Switches
Product Lifecycle:Active
Product description
Solenoid interlocks; Thermoplastic enclosure; Double-insulated; Interlock with protection against incorrect locking.; 130 mm x 90 mm x 30 mm; 6 Contacts; Long life
Product Details
- Voltage, Utilisation category DC13 24 VDC
- Current, Utilisation category DC13 2.5 A
- Current, Utilisation category AC-15 4 A
- Switching principle Creep circuit element
- Voltage, Utilisation category AC15 230 VAC
- Switching frequency 1,000 /h
- Required rated short-circuit current to EN 60947-5-1 1,000 A
- Electrical power consumption, maximum 10 W
- Switching element NO contact, NC contact
- Thermal test current 6 A
- Rated impulse withstand voltage Uimp 4 kV
- Rated insulation voltage Ui 250 V
- Rated control voltage 24 VAC/DC
- Ambient temperature, minimum -25 °C
- Ambient temperature, maximum +60 °C
- Height of sensor 90 mm
- Degree of protection IP67 to EN 60529
- Length of sensor 30 mm
- Width of sensor 130 mm
- Note (Cable section) All indications about the cable section are including the conductor ferrules.
- Cable section, maximum 1 x 1.5 mm²
- Cable section, minimum 1 x 0.25 mm²
- Terminal Connector Screw terminals
- positive break travel 10 mm
- Clamping force in accordance with ISO14119 Fzh 2,000 N
- Actuating speed, maximum 2 m/s
- Positive break force, minimum 20 N
- Mechanical life, minimum 1,000,000 Operations
- Actuating play in direction of actuation 5.5 mm
- Number of auxiliary contacts 2
- Number of safety contacts 4
- Gross weight 430 g
- Manual release Yes
- Power to unlock Yes
- Material of the contacts, electrical Silver
- Number of actuating directions 3
- Active principle electromechanical
- Enclosure material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Standards EN 60947-5-1, BG-GS-ET-19
- Coding level according to ISO 14119 Low
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
AZM 161SK-12/12K-024 Related Documents
Manufacturer warranty
AZM 161SK-12/12K-024 Schmersal
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare AZM 161SK-12/12K-024 with other products
Voltage, Utilisation category DC13
Current, Utilisation category DC13
Current, Utilisation category AC-15
Switching principle
Voltage, Utilisation category AC15
Switching frequency
Required rated short-circuit current to EN 60947-5-1
Electrical power consumption, maximum
Switching element
Thermal test current
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Rated control voltage
Ambient temperature, minimum
Ambient temperature, maximum
Height of sensor
Degree of protection
Length of sensor
Width of sensor
Note (Cable section)
Cable section, maximum
Cable section, minimum
Terminal Connector
positive break travel
Clamping force in accordance with ISO14119 Fzh
Actuating speed, maximum
Positive break force, minimum
Mechanical life, minimum
Actuating play in direction of actuation
Number of auxiliary contacts
Number of safety contacts
Gross weight
Manual release
Power to unlock
Material of the contacts, electrical
Number of actuating directions
Active principle
Enclosure material
Standards
Coding level according to ISO 14119
Current, Utilisation category DC13
Voltage, Utilisation category DC13
Current, Utilisation category AC-15
Switching principle
Switching element
Thermal test current
Ambient temperature, maximum
Voltage, Utilisation category AC15
Degree of protection
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
Ambient temperature, minimum
Height of sensor
Cable section, maximum
Terminal Connector
Length of sensor
Width of sensor
Cable entry
Cable section, minimum
Actuating speed, maximum
Positive break force, minimum
positive break travel
Mechanical life, minimum
Number of cable glands
Coding level according to ISO 14119
Material of the contacts, electrical
Latching force
Number of safety contacts
Gross weight
Enclosure material
Number of auxiliary contacts
Interfering radiation
EMC rating
Current, Utilisation category DC12
Voltage, Utilisation category DC13
Current, Utilisation category DC13
Versions
Voltage drop Ud, maximum
Current leakage Ir
Rated operating current (safety outputs)
Operating current
Required rated short-circuit current to EN 60947-5-1
Rated operating voltage, minimum
Voltage type
Rated operating voltage
No-load supply current I0
Protection rating
Overvoltage category
Restistance to shock
Material temperature resistance of the cable (in motion), minimum
Resistance to vibrations to EN 60068-2-6
Material temperature resistance (long-term), maximum
Degree of protection
Ambient temperature, minimum
Terminal Connector
Note (Repeat accuracy R)
Number of fail-safe digital outputs
Short-circuit recognition
Diagnostic output
Gross weight
Active area
Voltage, Utilisation category DC12
Switching frequency, approx.
Output current, (fail-safe output), maximum
Rated operating voltage, maximum
Degree of pollution to VDE 0100
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Material temperature resistance of the cable (at rest), minimum
Storage and transport temperature, maximum
Storage and transport temperature, minimum
Ambient temperature, maximum
Ensured switch distance ON Sao
Note
Length of sensor
Height of sensor
Width of sensor
Ensured switch distance OFF Sar
Switch distance
Hysteresis (Switch distance), maximum
Repeat accuracy R R
Mounting
Actuating panels
Number of semi-conductor outputs with signaling function
Number of LEDs
Cascadable
Integral System Diagnostics, status
Duration of risk, maximum
Safety functions
Time to readiness, maximum
Reaction time, maximum
Short circuit detection
Enclosure material
Sensor topology
Active principle
Standards
Installation conditions (mechanical)
Coding level according to ISO 14119
general information
Housing construction form
Selected product

AZM 161SK-12/12K-024
Schmersal
Solenoid interlocks; Thermoplastic enclosure; Double-insulated; Interlock with protection against in...
Voltage, Utilisation category DC1324 VDC
Current, Utilisation category DC132.5 A
Current, Utilisation category AC-154 A
Switching principleCreep circuit element
Voltage, Utilisation category AC15230 VAC
Switching frequency1,000 /h
Required rated short-circuit current to EN 60947-5-11,000 A
Electrical power consumption, maximum10 W
Switching elementNO contact, NC contact
Thermal test current6 A
Rated impulse withstand voltage Uimp4 kV
Rated insulation voltage Ui250 V
Rated control voltage24 VAC/DC
Ambient temperature, minimum-25 °C
Ambient temperature, maximum+60 °C
Height of sensor90 mm
Degree of protectionIP67 to EN 60529
Length of sensor30 mm
Width of sensor130 mm
Note (Cable section)All indications about the cable section are including the conductor ferrules.
Cable section, maximum1 x 1.5 mm²
Cable section, minimum1 x 0.25 mm²
Terminal ConnectorScrew terminals
positive break travel10 mm
Clamping force in accordance with ISO14119 Fzh2,000 N
Actuating speed, maximum2 m/s
Positive break force, minimum20 N
Mechanical life, minimum1,000,000 Operations
Actuating play in direction of actuation5.5 mm
Number of auxiliary contacts2
Number of safety contacts4
Gross weight430 g
Manual releaseYes
Power to unlockYes
Material of the contacts, electricalSilver
Number of actuating directions3
Active principleelectromechanical
Enclosure materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
StandardsEN 60947-5-1, BG-GS-ET-19
Coding level according to ISO 14119Low
Current, Utilisation category DC13-
Voltage, Utilisation category DC13-
Current, Utilisation category AC-15-
Switching principle-
Switching element-
Thermal test current-
Ambient temperature, maximum-
Voltage, Utilisation category AC15-
Degree of protection-
Rated insulation voltage Ui-
Rated impulse withstand voltage Uimp-
Ambient temperature, minimum-
Height of sensor-
Cable section, maximum-
Terminal Connector-
Length of sensor-
Width of sensor-
Cable entry-
Cable section, minimum-
Actuating speed, maximum-
Positive break force, minimum-
positive break travel-
Mechanical life, minimum-
Number of cable glands-
Coding level according to ISO 14119-
Material of the contacts, electrical-
Latching force-
Number of safety contacts-
Gross weight-
Enclosure material-
Number of auxiliary contacts-
Interfering radiation-
EMC rating-
Current, Utilisation category DC12-
Voltage, Utilisation category DC13-
Current, Utilisation category DC13-
Versions-
Voltage drop Ud, maximum-
Current leakage Ir-
Rated operating current (safety outputs)-
Operating current-
Required rated short-circuit current to EN 60947-5-1-
Rated operating voltage, minimum-
Voltage type-
Rated operating voltage-
No-load supply current I0-
Protection rating-
Overvoltage category-
Restistance to shock-
Material temperature resistance of the cable (in motion), minimum-
Resistance to vibrations to EN 60068-2-6-
Material temperature resistance (long-term), maximum-
Degree of protection-
Ambient temperature, minimum-
Terminal Connector-
Note (Repeat accuracy R)-
Number of fail-safe digital outputs-
Short-circuit recognition-
Diagnostic output-
Gross weight-
Active area-
Voltage, Utilisation category DC12-
Switching frequency, approx.-
Output current, (fail-safe output), maximum-
Rated operating voltage, maximum-
Degree of pollution to VDE 0100-
Rated impulse withstand voltage Uimp-
Rated insulation voltage Ui-
Material temperature resistance of the cable (at rest), minimum-
Storage and transport temperature, maximum-
Storage and transport temperature, minimum-
Ambient temperature, maximum-
Ensured switch distance ON Sao-
Note-
Length of sensor-
Height of sensor-
Width of sensor-
Ensured switch distance OFF Sar-
Switch distance-
Hysteresis (Switch distance), maximum-
Repeat accuracy R R-
Mounting-
Actuating panels-
Number of semi-conductor outputs with signaling function-
Number of LEDs-
Cascadable-
Integral System Diagnostics, status-
Duration of risk, maximum-
Safety functions-
Time to readiness, maximum-
Reaction time, maximum-
Short circuit detection-
Enclosure material-
Sensor topology-
Active principle-
Standards-
Installation conditions (mechanical)-
Coding level according to ISO 14119-
general information-
Housing construction form-
About the manufacturer

Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.
Recently viewed products
Relevant products
FAQ
Out if stock but available for backorder.
Solenoid interlocks; Thermoplastic enclosure; Double-insulated; Interlock with protection against incorrect locking.; 130 mm x 90 mm x 30 mm; 6 Contacts; Long life
Similar products from: Safety Switches
What can I help you find today?