AZM 161CC-12/12KA-024 Schmersal Safety Switches

AZM 161CC-12/12KA-024 on MQ Automation
Schmersal

Part#:AZM 161CC-12/12KA-024

Alt. Part#:101187946

Manufacturer:Schmersal

Category:Safety Switches

Product Lifecycle:Active

Product description

Solenoid interlocks; Large wiring compartment; Manual release; cable entries 4 M 16 x 1.5; Thermoplastic enclosure; Double-insulated; Interlock with protection against incorrect locking.; 130 mm x 90 mm x 30 mm; 6 Contacts; Long life

Product Details

  • Voltage, Utilisation category DC13
    24 VDC
  • Switching frequency
    1,000 /h
  • Current, Utilisation category AC-15
    4 A
  • Voltage, Utilisation category AC15
    230 VAC
  • Current, Utilisation category DC13
    2.5 A
  • Switching principle
    Creep circuit element
  • Switching element
    NO contact, NC contact
  • Electrical power consumption, maximum
    10 W
  • Required rated short-circuit current to EN 60947-5-1
    1,000 A
  • Rated control voltage
    24 VAC/DC
  • Rated impulse withstand voltage Uimp
    4 kV
  • Rated insulation voltage Ui
    250 V
  • Thermal test current
    6 A
  • Ambient temperature, maximum
    +60 °C
  • Ambient temperature, minimum
    -25 °C
  • Height of sensor
    90 mm
  • Width of sensor
    130 mm
  • Degree of protection
    IP67 to EN 60529
  • Length of sensor
    30 mm
  • Note (Cable section)
    All indications about the cable section are including the conductor ferrules.
  • Cable section, maximum
    1 x 1.5 mm²
  • Cable section, minimum
    1 x 0.25 mm²
  • Positive break force, minimum
    20 N
  • positive break travel
    10 mm
  • Terminal Connector
    Cage clamps
  • Actuating speed, maximum
    2 m/s
  • Clamping force in accordance with ISO14119 Fzh
    2,000 N
  • Actuating play in direction of actuation
    5.5 mm
  • Latching force
    5 N
  • Number of safety contacts
    4
  • Mechanical life, minimum
    1,000,000 Operations
  • Number of auxiliary contacts
    2
  • Active principle
    electromechanical
  • Manual release
    Yes
  • Number of actuating directions
    3
  • Material of the contacts, electrical
    Silver
  • Gross weight
    415 g
  • Power to lock
    Yes
  • Enclosure material
    Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
  • Standards
    EN 60947-5-1, BG-GS-ET-19
  • Coding level according to ISO 14119
    Low

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



AZM 161CC-12/12KA-024 Related Documents

Manufacturer warranty

AZM 161CC-12/12KA-024 Schmersal

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare AZM 161CC-12/12KA-024 with other products

Voltage, Utilisation category DC13

Switching frequency

Current, Utilisation category AC-15

Voltage, Utilisation category AC15

Current, Utilisation category DC13

Switching principle

Switching element

Electrical power consumption, maximum

Required rated short-circuit current to EN 60947-5-1

Rated control voltage

Rated impulse withstand voltage Uimp

Rated insulation voltage Ui

Thermal test current

Ambient temperature, maximum

Ambient temperature, minimum

Height of sensor

Width of sensor

Degree of protection

Length of sensor

Note (Cable section)

Cable section, maximum

Cable section, minimum

Positive break force, minimum

positive break travel

Terminal Connector

Actuating speed, maximum

Clamping force in accordance with ISO14119 Fzh

Actuating play in direction of actuation

Latching force

Number of safety contacts

Mechanical life, minimum

Number of auxiliary contacts

Active principle

Manual release

Number of actuating directions

Material of the contacts, electrical

Gross weight

Power to lock

Enclosure material

Standards

Coding level according to ISO 14119

Current, Utilisation category DC13

Voltage, Utilisation category DC13

Current, Utilisation category AC-15

Switching principle

Switching element

Thermal test current

Ambient temperature, maximum

Voltage, Utilisation category AC15

Degree of protection

Rated insulation voltage Ui

Rated impulse withstand voltage Uimp

Ambient temperature, minimum

Height of sensor

Cable section, maximum

Terminal Connector

Length of sensor

Width of sensor

Cable entry

Cable section, minimum

Actuating speed, maximum

Positive break force, minimum

positive break travel

Mechanical life, minimum

Number of cable glands

Coding level according to ISO 14119

Material of the contacts, electrical

Latching force

Number of safety contacts

Gross weight

Enclosure material

Number of auxiliary contacts

Interfering radiation

EMC rating

Current, Utilisation category DC12

Voltage, Utilisation category DC13

Current, Utilisation category DC13

Versions

Voltage drop Ud, maximum

Current leakage Ir

Rated operating current (safety outputs)

Operating current

Required rated short-circuit current to EN 60947-5-1

Rated operating voltage, minimum

Voltage type

Rated operating voltage

No-load supply current I0

Protection rating

Overvoltage category

Restistance to shock

Material temperature resistance of the cable (in motion), minimum

Resistance to vibrations to EN 60068-2-6

Material temperature resistance (long-term), maximum

Degree of protection

Ambient temperature, minimum

Terminal Connector

Note (Repeat accuracy R)

Number of fail-safe digital outputs

Short-circuit recognition

Diagnostic output

Gross weight

Active area

Voltage, Utilisation category DC12

Switching frequency, approx.

Output current, (fail-safe output), maximum

Rated operating voltage, maximum

Degree of pollution to VDE 0100

Rated impulse withstand voltage Uimp

Rated insulation voltage Ui

Material temperature resistance of the cable (at rest), minimum

Storage and transport temperature, maximum

Storage and transport temperature, minimum

Ambient temperature, maximum

Ensured switch distance ON Sao

Note

Length of sensor

Height of sensor

Width of sensor

Ensured switch distance OFF Sar

Switch distance

Hysteresis (Switch distance), maximum

Repeat accuracy R R

Mounting

Actuating panels

Number of semi-conductor outputs with signaling function

Number of LEDs

Cascadable

Integral System Diagnostics, status

Duration of risk, maximum

Safety functions

Time to readiness, maximum

Reaction time, maximum

Short circuit detection

Enclosure material

Sensor topology

Active principle

Standards

Installation conditions (mechanical)

Coding level according to ISO 14119

general information

Housing construction form

Selected product

AZM 161CC-12/12KA-024
0 in stock
AZM 161CC-12/12KA-024
Schmersal

Solenoid interlocks; Large wiring compartment; Manual release; cable entries 4 M 16 x 1.5; Thermopla...

Voltage, Utilisation category DC1324 VDC

Switching frequency1,000 /h

Current, Utilisation category AC-154 A

Voltage, Utilisation category AC15230 VAC

Current, Utilisation category DC132.5 A

Switching principleCreep circuit element

Switching elementNO contact, NC contact

Electrical power consumption, maximum10 W

Required rated short-circuit current to EN 60947-5-11,000 A

Rated control voltage24 VAC/DC

Rated impulse withstand voltage Uimp4 kV

Rated insulation voltage Ui250 V

Thermal test current6 A

Ambient temperature, maximum+60 °C

Ambient temperature, minimum-25 °C

Height of sensor90 mm

Width of sensor130 mm

Degree of protectionIP67 to EN 60529

Length of sensor30 mm

Note (Cable section)All indications about the cable section are including the conductor ferrules.

Cable section, maximum1 x 1.5 mm²

Cable section, minimum1 x 0.25 mm²

Positive break force, minimum20 N

positive break travel10 mm

Terminal ConnectorCage clamps

Actuating speed, maximum2 m/s

Clamping force in accordance with ISO14119 Fzh2,000 N

Actuating play in direction of actuation5.5 mm

Latching force5 N

Number of safety contacts4

Mechanical life, minimum1,000,000 Operations

Number of auxiliary contacts2

Active principleelectromechanical

Manual releaseYes

Number of actuating directions3

Material of the contacts, electricalSilver

Gross weight415 g

Power to lockYes

Enclosure materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing

StandardsEN 60947-5-1, BG-GS-ET-19

Coding level according to ISO 14119Low

Current, Utilisation category DC13-

Voltage, Utilisation category DC13-

Current, Utilisation category AC-15-

Switching principle-

Switching element-

Thermal test current-

Ambient temperature, maximum-

Voltage, Utilisation category AC15-

Degree of protection-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Ambient temperature, minimum-

Height of sensor-

Cable section, maximum-

Terminal Connector-

Length of sensor-

Width of sensor-

Cable entry-

Cable section, minimum-

Actuating speed, maximum-

Positive break force, minimum-

positive break travel-

Mechanical life, minimum-

Number of cable glands-

Coding level according to ISO 14119-

Material of the contacts, electrical-

Latching force-

Number of safety contacts-

Gross weight-

Enclosure material-

Number of auxiliary contacts-

Interfering radiation-

EMC rating-

Current, Utilisation category DC12-

Voltage, Utilisation category DC13-

Current, Utilisation category DC13-

Versions-

Voltage drop Ud, maximum-

Current leakage Ir-

Rated operating current (safety outputs)-

Operating current-

Required rated short-circuit current to EN 60947-5-1-

Rated operating voltage, minimum-

Voltage type-

Rated operating voltage-

No-load supply current I0-

Protection rating-

Overvoltage category-

Restistance to shock-

Material temperature resistance of the cable (in motion), minimum-

Resistance to vibrations to EN 60068-2-6-

Material temperature resistance (long-term), maximum-

Degree of protection-

Ambient temperature, minimum-

Terminal Connector-

Note (Repeat accuracy R)-

Number of fail-safe digital outputs-

Short-circuit recognition-

Diagnostic output-

Gross weight-

Active area-

Voltage, Utilisation category DC12-

Switching frequency, approx.-

Output current, (fail-safe output), maximum-

Rated operating voltage, maximum-

Degree of pollution to VDE 0100-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Material temperature resistance of the cable (at rest), minimum-

Storage and transport temperature, maximum-

Storage and transport temperature, minimum-

Ambient temperature, maximum-

Ensured switch distance ON Sao-

Note-

Length of sensor-

Height of sensor-

Width of sensor-

Ensured switch distance OFF Sar-

Switch distance-

Hysteresis (Switch distance), maximum-

Repeat accuracy R R-

Mounting-

Actuating panels-

Number of semi-conductor outputs with signaling function-

Number of LEDs-

Cascadable-

Integral System Diagnostics, status-

Duration of risk, maximum-

Safety functions-

Time to readiness, maximum-

Reaction time, maximum-

Short circuit detection-

Enclosure material-

Sensor topology-

Active principle-

Standards-

Installation conditions (mechanical)-

Coding level according to ISO 14119-

general information-

Housing construction form-

AZ 16-12ZVRK-M20
4 in stock
AZ 16-12ZVRK-M20
Schmersal

Safety switch with separate actuator; 3 cable entries M 20 x 1.5; Large wiring compartment; Thermopl...

Voltage, Utilisation category DC13-

Switching frequency-

Current, Utilisation category AC-15-

Voltage, Utilisation category AC15-

Current, Utilisation category DC13-

Switching principle-

Switching element-

Electrical power consumption, maximum-

Required rated short-circuit current to EN 60947-5-1-

Rated control voltage-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Thermal test current-

Ambient temperature, maximum-

Ambient temperature, minimum-

Height of sensor-

Width of sensor-

Degree of protection-

Length of sensor-

Note (Cable section)-

Cable section, maximum-

Cable section, minimum-

Positive break force, minimum-

positive break travel-

Terminal Connector-

Actuating speed, maximum-

Clamping force in accordance with ISO14119 Fzh-

Actuating play in direction of actuation-

Latching force-

Number of safety contacts-

Mechanical life, minimum-

Number of auxiliary contacts-

Active principle-

Manual release-

Number of actuating directions-

Material of the contacts, electrical-

Gross weight-

Power to lock-

Enclosure material-

Standards-

Coding level according to ISO 14119-

Current, Utilisation category DC134 A

Voltage, Utilisation category DC1324 VDC

Current, Utilisation category AC-154 A

Switching principleCreep circuit element

Switching elementNO contact, NC contact

Thermal test current10 A

Ambient temperature, maximum+80 °C

Voltage, Utilisation category AC15230 VAC

Degree of protectionIP67 to EN 60529

Rated insulation voltage Ui500 V

Rated impulse withstand voltage Uimp6 kV

Ambient temperature, minimum-30 °C

Height of sensor90 mm

Cable section, maximum2.5 mm²

Terminal ConnectorScrew connection

Length of sensor30 mm

Width of sensor52 mm

Cable entry3 x M20 x 1,5

Cable section, minimum0.25 mm²

Actuating speed, maximum2 m/s

Positive break force, minimum10 N

positive break travel8 mm

Mechanical life, minimum1,000,000 Operations

Number of cable glands3

Coding level according to ISO 14119Low

Material of the contacts, electricalSilver

Latching force30 N

Number of safety contacts2

Gross weight115 g

Enclosure materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing

Number of auxiliary contacts1

Interfering radiation-

EMC rating-

Current, Utilisation category DC12-

Voltage, Utilisation category DC13-

Current, Utilisation category DC13-

Versions-

Voltage drop Ud, maximum-

Current leakage Ir-

Rated operating current (safety outputs)-

Operating current-

Required rated short-circuit current to EN 60947-5-1-

Rated operating voltage, minimum-

Voltage type-

Rated operating voltage-

No-load supply current I0-

Protection rating-

Overvoltage category-

Restistance to shock-

Material temperature resistance of the cable (in motion), minimum-

Resistance to vibrations to EN 60068-2-6-

Material temperature resistance (long-term), maximum-

Degree of protection-

Ambient temperature, minimum-

Terminal Connector-

Note (Repeat accuracy R)-

Number of fail-safe digital outputs-

Short-circuit recognition-

Diagnostic output-

Gross weight-

Active area-

Voltage, Utilisation category DC12-

Switching frequency, approx.-

Output current, (fail-safe output), maximum-

Rated operating voltage, maximum-

Degree of pollution to VDE 0100-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Material temperature resistance of the cable (at rest), minimum-

Storage and transport temperature, maximum-

Storage and transport temperature, minimum-

Ambient temperature, maximum-

Ensured switch distance ON Sao-

Note-

Length of sensor-

Height of sensor-

Width of sensor-

Ensured switch distance OFF Sar-

Switch distance-

Hysteresis (Switch distance), maximum-

Repeat accuracy R R-

Mounting-

Actuating panels-

Number of semi-conductor outputs with signaling function-

Number of LEDs-

Cascadable-

Integral System Diagnostics, status-

Duration of risk, maximum-

Safety functions-

Time to readiness, maximum-

Reaction time, maximum-

Short circuit detection-

Enclosure material-

Sensor topology-

Active principle-

Standards-

Installation conditions (mechanical)-

Coding level according to ISO 14119-

general information-

Housing construction form-

RSS 36-D-ST
1 in stock
RSS 36-D-ST
Schmersal

Safety sensors; Electronic safety sensors; Universal coding with RFID technology; 1 x connector sock...

Voltage, Utilisation category DC13-

Switching frequency-

Current, Utilisation category AC-15-

Voltage, Utilisation category AC15-

Current, Utilisation category DC13-

Switching principle-

Switching element-

Electrical power consumption, maximum-

Required rated short-circuit current to EN 60947-5-1-

Rated control voltage-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Thermal test current-

Ambient temperature, maximum-

Ambient temperature, minimum-

Height of sensor-

Width of sensor-

Degree of protection-

Length of sensor-

Note (Cable section)-

Cable section, maximum-

Cable section, minimum-

Positive break force, minimum-

positive break travel-

Terminal Connector-

Actuating speed, maximum-

Clamping force in accordance with ISO14119 Fzh-

Actuating play in direction of actuation-

Latching force-

Number of safety contacts-

Mechanical life, minimum-

Number of auxiliary contacts-

Active principle-

Manual release-

Number of actuating directions-

Material of the contacts, electrical-

Gross weight-

Power to lock-

Enclosure material-

Standards-

Coding level according to ISO 14119-

Current, Utilisation category DC13-

Voltage, Utilisation category DC13-

Current, Utilisation category AC-15-

Switching principle-

Switching element-

Thermal test current-

Ambient temperature, maximum-

Voltage, Utilisation category AC15-

Degree of protection-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Ambient temperature, minimum-

Height of sensor-

Cable section, maximum-

Terminal Connector-

Length of sensor-

Width of sensor-

Cable entry-

Cable section, minimum-

Actuating speed, maximum-

Positive break force, minimum-

positive break travel-

Mechanical life, minimum-

Number of cable glands-

Coding level according to ISO 14119-

Material of the contacts, electrical-

Latching force-

Number of safety contacts-

Gross weight-

Enclosure material-

Number of auxiliary contacts-

Interfering radiationIEC 61000-6-4

EMC ratingIEC 60947-3

Current, Utilisation category DC120.05 A

Voltage, Utilisation category DC1324 VDC

Current, Utilisation category DC130.05 A

Versionsp-type

Voltage drop Ud, maximum2 V

Current leakage Ir0.5 mA

Rated operating current (safety outputs)250 mA

Operating current600 mA

Required rated short-circuit current to EN 60947-5-1100 A

Rated operating voltage, minimum20.4 VDC

Voltage typeDC (direct current)

Rated operating voltage24 VDC −15 % / +10 %

No-load supply current I0100 mA

Protection ratingIII

Overvoltage categoryIII

Restistance to shock30 g / 11 ms

Material temperature resistance of the cable (in motion), minimum-10 °C

Resistance to vibrations to EN 60068-2-610 … 55 Hz, amplitude 1 mm

Material temperature resistance (long-term), maximum+105 °C

Degree of protectionIP65 to EN 60529, IP67 to EN 60529, IP69 to EN 60529

Ambient temperature, minimum-25 °C

Terminal ConnectorConnector M12, 8-pole

Note (Repeat accuracy R)Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum clearance

Number of fail-safe digital outputs2

Short-circuit recognitionYes

Diagnostic outputYes

Gross weight80 g

Active arealateral

Voltage, Utilisation category DC1224 VDC

Switching frequency, approx.1 Hz

Output current, (fail-safe output), maximum0.25 A

Rated operating voltage, maximum26.4 VDC

Degree of pollution to VDE 01003

Rated impulse withstand voltage Uimp0.8 kV

Rated insulation voltage Ui32 VDC

Material temperature resistance of the cable (at rest), minimum-30 °C

Storage and transport temperature, maximum+85 °C

Storage and transport temperature, minimum-25 °C

Ambient temperature, maximum+70 °C

Ensured switch distance ON Sao10 mm

NoteThe cable section of the interconnecting cable must be observed! Cable length and cable section alter the voltage drop depending on the output current

Length of sensor22 mm

Height of sensor25 mm

Width of sensor106.3 mm

Ensured switch distance OFF Sar20 mm

Switch distance12 mm

Hysteresis (Switch distance), maximum2 mm

Repeat accuracy R R0.5 mm

MountingA screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used.

Actuating panelslateral

Number of semi-conductor outputs with signaling function1

Number of LEDs3

CascadableYes

Integral System Diagnostics, statusYes

Duration of risk, maximum200 ms

Safety functionsYes

Time to readiness, maximum2,000 ms

Reaction time, maximum100 ms

Short circuit detectionYes

Enclosure materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing

Sensor topologySensor for series wiring

Active principleRFID

StandardsIEC 60947-5-3

Installation conditions (mechanical)not flush

Coding level according to ISO 14119Low

general informationUniversal coding

Housing construction formBlock

About the manufacturer

Schmersal

Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.

Recently viewed products

Relevant products

FAQ

Out if stock but available for backorder.

Solenoid interlocks; Large wiring compartment; Manual release; cable entries 4 M 16 x 1.5; Thermoplastic enclosure; Double-insulated; Interlock with protection against incorrect locking.; 130 mm x 90 mm x 30 mm; 6 Contacts; Long life

Similar products from: Safety Switches

What can I help you find today?

Recommended parts