AZ 063 K 08106 Schmersal Safety Accessories

AZ 063 K 08106 on MQ Automation
Schmersal

Part#:AZ 063 K 08106

Alt. Part#:101194267

Manufacturer:Schmersal

Category:Safety Accessories

Product Lifecycle:Active

Product description

Positive-operation door contacts; 1 Actuating planes; cable ducts bottom side and rear; Thermoplastic enclosure; Contact pin in actuator bridge; transparent cover; Self-cleaning through the frictional mouvement of the contact bridges; Protection class IP2

Product Details

  • Switching principle
    Self-cleaning pressure contact
  • Switching element
    Opener (NC)
  • Utilisation category AC-15
    230 VAC
  • Utilisation category DC-13
    200 VDC
  • Thermal test current
    4 A
  • Rated insulation voltage Ui
    500 V
  • Note (Relative humidity)
    non-condensing
  • Relative humidity, maximum
    95 %
  • Ambient temperature, maximum
    +70 °C
  • Ambient temperature, minimum
    -30 °C
  • Depth
    19 mm
  • Degree of protection
    IP20
  • Height
    27 mm
  • Actuating panels
    1
  • Width
    50 mm
  • Number of safety contacts
    1
  • Note (Cable entry)
    Cable ducts bottom side and rear
  • Notes
    M4 slotted-head combination screws, similar to DIN 7984, with self-opening clamp plates
  • Cable entry
    2 x single conductor version with connecting funnel
  • Tightening torque of electrical connection, maximum
    1.2 Nm
  • Suitable for elevators
    Yes
  • Enclosure material
    Glass-fibre reinforced ultramid, self-extinguishing
  • Terminal Connector
    Screw connection
  • Mounting
    Round holes
  • Actuating force
    1.6 N
  • Actuating stroke
    7 mm
  • Material of the contacts, electrical
    Silver-plated Cu rivets
  • Standards
    EN 81-20, EN 81-50, CAN/CSA-B44.1
  • Gross weight
    23.5 g
  • Material of the cover
    Glass-fibre reinforced ultramid, self-extinguishing
  • Mechanical life, minimum
    10,000,000 Operations

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



AZ 063 K 08106 Related Documents

Manufacturer warranty

AZ 063 K 08106 Schmersal

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare AZ 063 K 08106 with other products

Switching principle

Switching element

Utilisation category AC-1...

Utilisation category DC-1...

Thermal test current

Rated insulation voltage ...

Note (Relative humidity)

Relative humidity, maximu...

Ambient temperature, maxi...

Ambient temperature, mini...

Depth

Degree of protection

Height

Actuating panels

Width

Number of safety contacts

Note (Cable entry)

Notes

Cable entry

Tightening torque of elec...

Suitable for elevators

Enclosure material

Terminal Connector

Mounting

Actuating force

Actuating stroke

Material of the contacts,...

Standards

Gross weight

Material of the cover

Mechanical life, minimum

Current, Utilisation cate...

Voltage, Utilisation cate...

Current, Utilisation cate...

Voltage, Utilisation cate...

Rated impulse withstand v...

Height of sensor

Cable section, maximum

Length of sensor

Width of sensor

Cable section, minimum

Actuating speed, maximum

Positive break force, min...

positive break travel

Number of cable glands

Coding level according to...

Latching force

Number of auxiliary conta...

Interfering radiation

EMC rating

Current, Utilisation cate...

Versions

Voltage drop Ud, maximum

Current leakage Ir

Rated operating current (...

Operating current

Required rated short-circ...

Rated operating voltage, ...

Voltage type

Rated operating voltage

No-load supply current I0

Protection rating

Overvoltage category

Restistance to shock

Material temperature resi...

Resistance to vibrations ...

Material temperature resi...

Note (Repeat accuracy R)

Number of fail-safe digit...

Short-circuit recognition

Diagnostic output

Active area

Voltage, Utilisation cate...

Switching frequency, appr...

Output current, (fail-saf...

Rated operating voltage, ...

Degree of pollution to VD...

Material temperature resi...

Storage and transport tem...

Storage and transport tem...

Ensured switch distance O...

Note

Ensured switch distance O...

Switch distance

Hysteresis (Switch distan...

Repeat accuracy R R

Number of semi-conductor ...

Number of LEDs

Cascadable

Integral System Diagnosti...

Duration of risk, maximum

Safety functions

Time to readiness, maximu...

Reaction time, maximum

Short circuit detection

Sensor topology

Active principle

Installation conditions (...

general information

Housing construction form

Selected product

AZ 063 K 08106
0 in stock
AZ 063 K 08106
Schmersal

Positive-operation door contacts; 1 Actuating planes; cable ducts bottom side and rear; Thermoplasti...

Switching principleSelf-cleaning pressure conta...

Switching elementOpener (NC)

Utilisation category AC-15230 VAC

Utilisation category DC-13200 VDC

Thermal test current4 A

Rated insulation voltage Ui500 V

Note (Relative humidity)non-condensing

Relative humidity, maximum95 %

Ambient temperature, maximum+70 °C

Ambient temperature, minimum-30 °C

Depth19 mm

Degree of protectionIP20

Height27 mm

Actuating panels1

Width50 mm

Number of safety contacts1

Note (Cable entry)Cable ducts bottom side and ...

NotesM4 slotted-head combination ...

Cable entry2 x single conductor version...

Tightening torque of electrical connection, maximum1.2 Nm

Suitable for elevatorsYes

Enclosure materialGlass-fibre reinforced ultra...

Terminal ConnectorScrew connection

MountingRound holes

Actuating force1.6 N

Actuating stroke7 mm

Material of the contacts, electricalSilver-plated Cu rivets

StandardsEN 81-20, EN 81-50, CAN/CSA-...

Gross weight23.5 g

Material of the coverGlass-fibre reinforced ultra...

Mechanical life, minimum10,000,000 Operations

Current, Utilisation category DC13-

Voltage, Utilisation category DC13-

Current, Utilisation category AC-15-

Voltage, Utilisation category AC15-

Rated impulse withstand voltage Uimp-

Height of sensor-

Cable section, maximum-

Length of sensor-

Width of sensor-

Cable section, minimum-

Actuating speed, maximum-

Positive break force, minimum-

positive break travel-

Number of cable glands-

Coding level according to ISO 14119-

Latching force-

Number of auxiliary contacts-

Interfering radiation-

EMC rating-

Current, Utilisation category DC12-

Versions-

Voltage drop Ud, maximum-

Current leakage Ir-

Rated operating current (safety outputs)-

Operating current-

Required rated short-circuit current to EN 60947-5-1-

Rated operating voltage, minimum-

Voltage type-

Rated operating voltage-

No-load supply current I0-

Protection rating-

Overvoltage category-

Restistance to shock-

Material temperature resistance of the cable (in motion), minimum-

Resistance to vibrations to EN 60068-2-6-

Material temperature resistance (long-term), maximum-

Note (Repeat accuracy R)-

Number of fail-safe digital outputs-

Short-circuit recognition-

Diagnostic output-

Active area-

Voltage, Utilisation category DC12-

Switching frequency, approx.-

Output current, (fail-safe output), maximum-

Rated operating voltage, maximum-

Degree of pollution to VDE 0100-

Material temperature resistance of the cable (at rest), minimum-

Storage and transport temperature, maximum-

Storage and transport temperature, minimum-

Ensured switch distance ON Sao-

Note-

Ensured switch distance OFF Sar-

Switch distance-

Hysteresis (Switch distance), maximum-

Repeat accuracy R R-

Number of semi-conductor outputs with signaling function-

Number of LEDs-

Cascadable-

Integral System Diagnostics, status-

Duration of risk, maximum-

Safety functions-

Time to readiness, maximum-

Reaction time, maximum-

Short circuit detection-

Sensor topology-

Active principle-

Installation conditions (mechanical)-

general information-

Housing construction form-

AZ 16-12ZVRK-M20
4 in stock
AZ 16-12ZVRK-M20
Schmersal

Safety switch with separate actuator; 3 cable entries M 20 x 1.5; Large wiring compartment; Thermopl...

Switching principleCreep circuit element

Switching elementNO contact, NC contact

Utilisation category AC-15-

Utilisation category DC-13-

Thermal test current10 A

Rated insulation voltage Ui500 V

Note (Relative humidity)-

Relative humidity, maximum-

Ambient temperature, maximum+80 °C

Ambient temperature, minimum-30 °C

Depth-

Degree of protectionIP67 to EN 60529

Height-

Actuating panels-

Width-

Number of safety contacts2

Note (Cable entry)-

Notes-

Cable entry3 x M20 x 1,5

Tightening torque of electrical connection, maximum-

Suitable for elevators-

Enclosure materialPlastic, glass-fibre reinfor...

Terminal ConnectorScrew connection

Mounting-

Actuating force-

Actuating stroke-

Material of the contacts, electricalSilver

Standards-

Gross weight115 g

Material of the cover-

Mechanical life, minimum1,000,000 Operations

Current, Utilisation category DC134 A

Voltage, Utilisation category DC1324 VDC

Current, Utilisation category AC-154 A

Voltage, Utilisation category AC15230 VAC

Rated impulse withstand voltage Uimp6 kV

Height of sensor90 mm

Cable section, maximum2.5 mm²

Length of sensor30 mm

Width of sensor52 mm

Cable section, minimum0.25 mm²

Actuating speed, maximum2 m/s

Positive break force, minimum10 N

positive break travel8 mm

Number of cable glands3

Coding level according to ISO 14119Low

Latching force30 N

Number of auxiliary contacts1

Interfering radiation-

EMC rating-

Current, Utilisation category DC12-

Versions-

Voltage drop Ud, maximum-

Current leakage Ir-

Rated operating current (safety outputs)-

Operating current-

Required rated short-circuit current to EN 60947-5-1-

Rated operating voltage, minimum-

Voltage type-

Rated operating voltage-

No-load supply current I0-

Protection rating-

Overvoltage category-

Restistance to shock-

Material temperature resistance of the cable (in motion), minimum-

Resistance to vibrations to EN 60068-2-6-

Material temperature resistance (long-term), maximum-

Note (Repeat accuracy R)-

Number of fail-safe digital outputs-

Short-circuit recognition-

Diagnostic output-

Active area-

Voltage, Utilisation category DC12-

Switching frequency, approx.-

Output current, (fail-safe output), maximum-

Rated operating voltage, maximum-

Degree of pollution to VDE 0100-

Material temperature resistance of the cable (at rest), minimum-

Storage and transport temperature, maximum-

Storage and transport temperature, minimum-

Ensured switch distance ON Sao-

Note-

Ensured switch distance OFF Sar-

Switch distance-

Hysteresis (Switch distance), maximum-

Repeat accuracy R R-

Number of semi-conductor outputs with signaling function-

Number of LEDs-

Cascadable-

Integral System Diagnostics, status-

Duration of risk, maximum-

Safety functions-

Time to readiness, maximum-

Reaction time, maximum-

Short circuit detection-

Sensor topology-

Active principle-

Installation conditions (mechanical)-

general information-

Housing construction form-

RSS 36-D-ST
1 in stock
RSS 36-D-ST
Schmersal

Safety sensors; Electronic safety sensors; Universal coding with RFID technology; 1 x connector sock...

Switching principle-

Switching element-

Utilisation category AC-15-

Utilisation category DC-13-

Thermal test current-

Rated insulation voltage Ui32 VDC

Note (Relative humidity)-

Relative humidity, maximum-

Ambient temperature, maximum+70 °C

Ambient temperature, minimum-25 °C

Depth-

Degree of protectionIP65 to EN 60529, IP67 to EN...

Height-

Actuating panelslateral

Width-

Number of safety contacts-

Note (Cable entry)-

Notes-

Cable entry-

Tightening torque of electrical connection, maximum-

Suitable for elevators-

Enclosure materialPlastic, glass-fibre reinfor...

Terminal ConnectorConnector M12, 8-pole

MountingA screw length of 25 mm is s...

Actuating force-

Actuating stroke-

Material of the contacts, electrical-

StandardsIEC 60947-5-3

Gross weight80 g

Material of the cover-

Mechanical life, minimum-

Current, Utilisation category DC130.05 A

Voltage, Utilisation category DC1324 VDC

Current, Utilisation category AC-15-

Voltage, Utilisation category AC15-

Rated impulse withstand voltage Uimp0.8 kV

Height of sensor25 mm

Cable section, maximum-

Length of sensor22 mm

Width of sensor106.3 mm

Cable section, minimum-

Actuating speed, maximum-

Positive break force, minimum-

positive break travel-

Number of cable glands-

Coding level according to ISO 14119Low

Latching force-

Number of auxiliary contacts-

Interfering radiationIEC 61000-6-4

EMC ratingIEC 60947-3

Current, Utilisation category DC120.05 A

Versionsp-type

Voltage drop Ud, maximum2 V

Current leakage Ir0.5 mA

Rated operating current (safety outputs)250 mA

Operating current600 mA

Required rated short-circuit current to EN 60947-5-1100 A

Rated operating voltage, minimum20.4 VDC

Voltage typeDC (direct current)

Rated operating voltage24 VDC −15 % / +10 %

No-load supply current I0100 mA

Protection ratingIII

Overvoltage categoryIII

Restistance to shock30 g / 11 ms

Material temperature resistance of the cable (in motion), minimum-10 °C

Resistance to vibrations to EN 60068-2-610 … 55 Hz, amplitude 1 mm

Material temperature resistance (long-term), maximum+105 °C

Note (Repeat accuracy R)Axial offset: The long side ...

Number of fail-safe digital outputs2

Short-circuit recognitionYes

Diagnostic outputYes

Active arealateral

Voltage, Utilisation category DC1224 VDC

Switching frequency, approx.1 Hz

Output current, (fail-safe output), maximum0.25 A

Rated operating voltage, maximum26.4 VDC

Degree of pollution to VDE 01003

Material temperature resistance of the cable (at rest), minimum-30 °C

Storage and transport temperature, maximum+85 °C

Storage and transport temperature, minimum-25 °C

Ensured switch distance ON Sao10 mm

NoteThe cable section of the int...

Ensured switch distance OFF Sar20 mm

Switch distance12 mm

Hysteresis (Switch distance), maximum2 mm

Repeat accuracy R R0.5 mm

Number of semi-conductor outputs with signaling function1

Number of LEDs3

CascadableYes

Integral System Diagnostics, statusYes

Duration of risk, maximum200 ms

Safety functionsYes

Time to readiness, maximum2,000 ms

Reaction time, maximum100 ms

Short circuit detectionYes

Sensor topologySensor for series wiring

Active principleRFID

Installation conditions (mechanical)not flush

general informationUniversal coding

Housing construction formBlock

About the manufacturer

Schmersal

Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.

Recently viewed products

Relevant products

FAQ

Out if stock but available for backorder.

Positive-operation door contacts; 1 Actuating planes; cable ducts bottom side and rear; Thermoplastic enclosure; Contact pin in actuator bridge; transparent cover; Self-cleaning through the frictional mouvement of the contact bridges; Protection class IP2

What can I help you find today?

Recommended parts