169897 Euchner Safety Locking Systems

169897 on MQ Automation
Euchner

Part#:169897

Alt. Part#:MGB2-L1-MLI-U-YB1D7-DA-R-169897

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

Product description

169897 Euchner - Locking module MGB2-L1-MLI... (2 pushbuttons, machine stop, closed-circuit current principle, door hinge on right)

Product Details

  • Weight
    3.0203294 lb
  • Series
    MGB2-MLI
  • Product Class
    Safety System

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


About the product

Guard locking for the protection of persons or processes;Locking module MGB2 for connection to a bus module MBM;Interlocking with monitored guard locking;Category 4/PL e for the evaluation of all safety functions;1 machine stop;2 illuminated pushbuttons;3 cut-outs for slide-in labels;Adjustable door hinge; factory setting: right;Unicode;Compatible with all Modular devices


Manufacturer warranty

169897 Euchner

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 169897 with other products

Weight

Series

Product Class

Switching hysteresis

Assured operating distance Sao

Assured release distance Sar

PFHD

Operating distance

Mission time

Performance Level

Category

For the approval acc. to UL the following applies

Repeat accuracy R

Discrepancy time

Off-state current Ir

Utilization category acc. to EN 60947-5-2

Rated conditional short-circuit current

Test pulses

Test-pulse interval

Output voltage

Switching current

Turn-on time

Risk time according to EN 60947-5-3

Type of output

Fusing

Rated impulse withstand voltage Uimp

Rated insulation voltage Ui

Degree of contamination (external, according to EN 60947-1)

Safety class

EMC protection requirements

Extension of risk time according to EN 60947-5-3 per device

Tightening torque

Current consumption

Installation orientation

Mounting distance

Operating voltage DC

Connection

Switching frequency

Ready delay

Cable ambient temperature (dynamic)

Degree of protection

Mounting method

Static bending radius

Weight

Shock and vibration resistance

Cable ambient temperature (static)

Housing material

Dynamic bending radius

Selected product

169897
0 in stock
169897
Euchner

169897 Euchner - Locking module MGB2-L1-MLI... (2 pushbuttons, machine stop, closed-circuit current ...

Weight3.0203294 lb

SeriesMGB2-MLI

Product ClassSafety System

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

PFHD-

Operating distance-

Mission time-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Utilization category acc. to EN 60947-5-2-

Rated conditional short-circuit current-

Test pulses-

Test-pulse interval-

Output voltage-

Switching current-

Turn-on time-

Risk time according to EN 60947-5-3-

Type of output-

Fusing-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Degree of contamination (external, according to EN 60947-1)-

Safety class-

EMC protection requirements-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Current consumption-

Installation orientation-

Mounting distance-

Operating voltage DC-

Connection-

Switching frequency-

Ready delay-

Cable ambient temperature (dynamic)-

Degree of protection-

Mounting method-

Static bending radius-

Weight-

Shock and vibration resistance-

Cable ambient temperature (static)-

Housing material-

Dynamic bending radius-

084430
5 in stock
084430
Euchner

084430 Euchner - Bolt for safety switch GP and TP

Weight4.55033568 lb

SeriesMetal bolt

Product ClassBolts

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

PFHD-

Operating distance-

Mission time-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Utilization category acc. to EN 60947-5-2-

Rated conditional short-circuit current-

Test pulses-

Test-pulse interval-

Output voltage-

Switching current-

Turn-on time-

Risk time according to EN 60947-5-3-

Type of output-

Fusing-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Degree of contamination (external, according to EN 60947-1)-

Safety class-

EMC protection requirements-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Current consumption-

Installation orientation-

Mounting distance-

Operating voltage DC-

Connection-

Switching frequency-

Ready delay-

Cable ambient temperature (dynamic)-

Degree of protection-

Mounting method-

Static bending radius-

Weight-

Shock and vibration resistance-

Cable ambient temperature (static)-

Housing material-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

PFHD1.9 x 10⁻⁹

Operating distance19 mm

Mission time20

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)

Rated conditional short-circuit current100 A

Test pulsesmax.1 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Test-pulse intervalmin.140 ms

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-proof

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.1 Nm

Current consumptionmax.50 mA (Without taking into account the load currents on the monitoring output and the safety outputs)

Installation orientationAny

Mounting distancemin.120 mm

Operating voltage DC24 V DC 15% ... 15% Regulated, residual ripple < 5 %

ConnectionConnection cable PUR, length 1m with plug connector M12 8-pin

Switching frequencymax.1 Hz

Ready delay10 s

Cable ambient temperature (dynamic)-25 ... 65 °C

Degree of protectionIP67

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Weight0,09 kg

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Housing materialPlastic, PBT

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

Out if stock but available for backorder.

169897 Euchner - Locking module MGB2-L1-MLI... (2 pushbuttons, machine stop, closed-circuit current principle, door hinge on right)

What can I help you find today?

Recommended parts