164353 Euchner Safety Locking Systems

164353 on MQ Automation
Euchner
  • 164353
  • 164353
  • 164353

Part#:164353

Alt. Part#:MGBS-P-L2-AR-U-R-AE-SH-164353

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

8 in stock

Mar 15, 2025

Product description

164353 Euchner - MGBS-AR, M23, with escape release, door hinge on right

Product Details

  • Weight
    4.629702 lb
  • Series
    MGBS-AR
  • Product Class
    Safety System
  • Mission time
    20 y
  • PFHD
    4.1 x 10 ⁻⁹
  • Category
    4
  • Additional feature
    Escape release actuated by pushing
  • Repeat accuracy R
    10 %
  • Turn-on time
    max.400 ms
  • Performance Level
    PL e
  • Off-state current Ir
    max.0,25 mA
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Output voltage
    0 ... 1 V DC
  • Discrepancy time
    max.10 ms In acc. with EN IEC 60947-5-3
  • Switching current
    1 ... 150 mA
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Switching load
    24V DC, class 2 (Alternatively see operating instructions)
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Safety class
    III
  • Solenoid duty cycle
    100 %
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Connection rating
    6 W
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated insulation voltage Ui
    50 V
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Fusing
    0,5 ... 8 A
  • Test pulses
    max.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Overtravel
    5 mm
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Test-pulse interval
    min.140 ms
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Current consumption
    40 mA
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Locking force FZh
    3000 N (Fzh = Fmax/1.3 Depending on the actuator used)
  • Actuating force
    10 N
  • Locking force Fmax
    3900 N
  • Retention force
    20 N
  • Extraction force
    20 N
  • Connection
    1 plug connector M23, 19-pin, RC18
  • Switching frequency
    max.0,5 Hz
  • Approach speed
    max.20 m/min
  • Guard locking principle
    Open-circuit current principle
  • Ready delay
    8 s
  • Mechanical life
    1 x 10⁶
  • Ambient temperature
    -20 ... +55 °C
  • Housing material
    Die-cast zinc
  • Weight
    1,5 kg
  • Installation orientation
    Door hinge DIN right
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 164353 on MQ Automation is $1,161.33. Order now.


About the product

Locking module (order handle module separately);Adjustable door hinge; factory setting: right;Series connection possible (up to 20 AR devices in series);Short circuit monitoring;2 safety outputs (semiconductor outputs);Up to category 4 / PL e according to EN ISO 13849-1;With plug connector M23;Unicode;Door position monitoring output;With escape release (order inner door handle separately)


This item can ship in 3-5 days!

Manufacturer warranty

164353 Euchner

$1,161.33

Your price can be lower.
Log in or Create account to check your discount

Stock:

8

Select Qty:

$1,161.33

$1,161.33 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 164353 with other products

Weight

Series

Product Class

Mission time

PFHD

Category

Additional feature

Repeat accuracy R

Turn-on time

Performance Level

Off-state current Ir

For the approval acc. to ...

Output voltage

Discrepancy time

Switching current

Type of output

Switching load

Risk time according to EN...

Safety class

Solenoid duty cycle

Rated impulse withstand v...

Connection rating

EMC protection requiremen...

Degree of contamination (...

Rated insulation voltage ...

Operating voltage DC

Fusing

Test pulses

Overtravel

Solenoid operating voltag...

Test-pulse interval

Utilization category acc....

Current consumption

Extension of risk time ac...

Locking force FZh

Actuating force

Locking force Fmax

Retention force

Extraction force

Connection

Switching frequency

Approach speed

Guard locking principle

Ready delay

Mechanical life

Ambient temperature

Housing material

Installation orientation

Shock and vibration resis...

Degree of protection

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

164353
8 in stock
164353
Euchner

164353 Euchner - MGBS-AR, M23, with escape release, door hinge on right

Weight4.629702 lb

SeriesMGBS-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Performance LevelPL e

Off-state current Irmax.0,25 mA

For the approval acc. to UL the following appliesOperation only with UL class...

Output voltage0 ... 1 V DC

Discrepancy timemax.10 ms In acc. with EN ...

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Solenoid duty cycle100 %

Rated impulse withstand voltage Uimp0,5 kV

Connection rating6 W

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Operating voltage DC24 V DC -15% ... 15% Rev...

Fusing0,5 ... 8 A

Test pulsesmax.1,0 ms (Applies for a l...

Overtravel5 mm

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Test-pulse intervalmin.140 ms

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Actuating force10 N

Locking force Fmax3900 N

Retention force20 N

Extraction force20 N

Connection1 plug connector M23, 19-pin...

Switching frequencymax.0,5 Hz

Approach speedmax.20 m/min

Guard locking principleOpen-circuit current princip...

Ready delay8 s

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Housing materialDie-cast zinc

Installation orientationDoor hinge DIN right

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of protectionIP67 (Screwed tight plug co...

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Performance LevelPL e

Off-state current Irmax.0,25 mA

For the approval acc. to UL the following appliesOperation only with UL class...

Output voltage0,8xUB ... UB V DC

Discrepancy timemax.10 ms In acc. with EN ...

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Solenoid duty cycle100 %

Rated impulse withstand voltage Uimp0,5 kV

Connection rating6 W

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Operating voltage DC24 V DC -15% ... 15% Rev...

Fusing0,25 ... 8 A

Test pulsesmax.1,0 ms (Applies for a l...

Overtravel5 mm

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Test-pulse intervalmin.140 ms

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Actuating force10 N

Locking force Fmax3900 N

Retention force20 N

Extraction force20 N

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Approach speedmax.20 m/min

Guard locking principleClosed-circuit current princ...

Ready delay8 s

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Housing materialDie-cast zinc

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of protectionIP67/IP69/IP69K (Screwed ti...

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Additional feature-

Repeat accuracy R10 %

Turn-on timemax.400 ms

Performance LevelPL e

Off-state current Irmax.0,25 mA

For the approval acc. to UL the following appliesOperation only with UL class...

Output voltage0 ... 1 V DC

Discrepancy timemax.10 ms In acc. with EN ...

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3-

Safety classIII

Solenoid duty cycle-

Rated impulse withstand voltage Uimp0,5 kV

Connection rating1 W

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Operating voltage DC24 V DC -15% ... 15% Rev...

Fusing0,25 ... 8 A

Test pulsesmax.0,3 ms (Applies for a l...

Overtravel5 mm

Solenoid operating voltage DC-

Test-pulse intervalmin.100 ms

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Extension of risk time according to EN 60947-5-3 per device-

Locking force FZh-

Actuating force10 N

Locking force Fmax-

Retention force-

Extraction force20 N

Connection2 plug connectors M12, 5-pin

Switching frequencymax.0,5 Hz

Approach speedmax.20 m/min

Guard locking principle-

Ready delaymax.1 s

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Housing materialFiber glass reinforced therm...

Installation orientationDoor hinge DIN right

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of protectionIP65 (Screwed tight plug co...

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 164353?
The price of 164353 on MQ Automation is $1,161.33. Order now.

Out if stock but available for backorder.

164353 Euchner - MGBS-AR, M23, with escape release, door hinge on right

What can I help you find today?

Recommended parts