161206 Euchner Safety Locking Systems

161206 on MQ Automation
Euchner
  • 161206
  • 161206
  • 161206

Part#:161206

Alt. Part#:MGBS-P-L1-AR-U-R-AEE-SH-161206

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

Product description

161206 Euchner - MGBS-AR, M23, 1 pushbutton, with escape release, door hinge on right

Product Details

  • Weight
    4.80166236 lb
  • Series
    MGBS-AR
  • Product Class
    Safety System
  • Mission time
    20 y
  • Performance Level
    PL e
  • PFHD
    4.1 x 10 ⁻⁹
  • Category
    4
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Additional feature
    Incl. cover set ID. No. 120344
  • Switching element
    1NO
  • Version
    Illuminated push buttons
  • Discrepancy time
    max.10 ms In acc. with EN IEC 60947-5-3
  • Power supply
    24 V
  • Repeat accuracy R
    10 %
  • Operating current
    1 ... 50 mA
  • Turn-on time
    max.400 ms
  • Switching load
    24V DC, class 2 (Alternatively see operating instructions)
  • Operating voltage
    UB V
  • Off-state current Ir
    max.0,25 mA
  • Output voltage
    0 ... 1 V DC
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Switching current
    1 ... 150 mA
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Safety class
    III
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Rated insulation voltage Ui
    50 V
  • Solenoid duty cycle
    100 %
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Connection rating
    6 W
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Fusing
    0,5 ... 8 A
  • Test pulses
    max.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Current consumption
    40 mA
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Test-pulse interval
    min.140 ms
  • Overtravel
    5 mm
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Locking force FZh
    3000 N (Fzh = Fmax/1.3 Depending on the actuator used)
  • Retention force
    20 N
  • Actuating force
    10 N
  • Extraction force
    20 N
  • Locking force Fmax
    3900 N
  • Guard locking principle
    Closed-circuit current principle
  • Approach speed
    max.20 m/min
  • Connection
    1 plug connector M23, 19-pin, RC18
  • Housing material
    Fiber glass reinforced thermoplastic
  • Weight
    1,5 kg
  • Ambient temperature
    -20 ... +55 °C
  • Installation orientation
    Door hinge DIN right
  • Degree of protection
    IP65 (Screwed tight plug connector/mating component)
  • Switching frequency
    max.0,5 Hz
  • Mechanical life
    1 x 10⁶
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Ready delay
    8 s

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 161206 on MQ Automation is $1,280.17. Order now.


About the product

Locking module (order handle module separately);Adjustable door hinge; factory setting: right;Series connection possible (up to 20 AR devices in series);Short circuit monitoring;2 safety outputs (semiconductor outputs);Up to category 4 / PL e according to EN ISO 13849-1;1 pushbuttons (illuminated);With plug connector M23;Unicode;Door position monitoring output;With escape release (order inner door handle separately)


Manufacturer warranty

161206 Euchner

$1,280.17

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,280.17

$1,280.17 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 161206 with other products

Weight

Series

Product Class

Mission time

Performance Level

PFHD

Category

For the approval acc. to ...

Additional feature

Switching element

Version

Discrepancy time

Power supply

Repeat accuracy R

Operating current

Turn-on time

Switching load

Operating voltage

Off-state current Ir

Output voltage

Type of output

Switching current

Risk time according to EN...

Safety class

Rated impulse withstand v...

Rated insulation voltage ...

Solenoid duty cycle

Degree of contamination (...

EMC protection requiremen...

Connection rating

Solenoid operating voltag...

Fusing

Test pulses

Utilization category acc....

Current consumption

Operating voltage DC

Test-pulse interval

Overtravel

Extension of risk time ac...

Locking force FZh

Retention force

Actuating force

Extraction force

Locking force Fmax

Guard locking principle

Approach speed

Connection

Housing material

Ambient temperature

Installation orientation

Degree of protection

Switching frequency

Mechanical life

Shock and vibration resis...

Ready delay

B10D

Detent mechanism

Selected product

161206
0 in stock
161206
Euchner

161206 Euchner - MGBS-AR, M23, 1 pushbutton, with escape release, door hinge on right

Weight4.80166236 lb

SeriesMGBS-AR

Product ClassSafety System

Mission time20 y

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureIncl. cover set ID. No. 1203...

Switching element1NO

VersionIlluminated push buttons

Discrepancy timemax.10 ms In acc. with EN ...

Power supply24 V

Repeat accuracy R10 %

Operating current1 ... 50 mA

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Operating voltageUB V

Off-state current Irmax.0,25 mA

Output voltage0 ... 1 V DC

Type of output2 semiconductor outputs, p-s...

Switching current1 ... 150 mA

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Solenoid duty cycle100 %

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Fusing0,5 ... 8 A

Test pulsesmax.1,0 ms (Applies for a l...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Test-pulse intervalmin.140 ms

Overtravel5 mm

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Retention force20 N

Actuating force10 N

Extraction force20 N

Locking force Fmax3900 N

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Connection1 plug connector M23, 19-pin...

Housing materialFiber glass reinforced therm...

Ambient temperature-20 ... +55 °C

Installation orientationDoor hinge DIN right

Degree of protectionIP65 (Screwed tight plug co...

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ready delay8 s

B10D-

Detent mechanism-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Switching element-

Version-

Discrepancy timemax.10 ms In acc. with EN ...

Power supply-

Repeat accuracy R10 %

Operating current-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Operating voltage-

Off-state current Irmax.0,25 mA

Output voltage0,8xUB ... UB V DC

Type of outputp-switching, short circuit-p...

Switching current1 ... 50 mA

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Solenoid duty cycle100 %

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Fusing0,25 ... 8 A

Test pulsesmax.1,0 ms (Applies for a l...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Test-pulse intervalmin.140 ms

Overtravel5 mm

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Retention force20 N

Actuating force10 N

Extraction force20 N

Locking force Fmax3900 N

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5 and...

Housing materialDie-cast zinc

Ambient temperature-20 ... +55 °C

Installation orientationAny

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ready delay8 s

B10D-

Detent mechanism-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Switching element2 pos. driven NC

VersionEmergency stop

Discrepancy timemax.10 ms In acc. with EN ...

Power supply-

Repeat accuracy R10 %

Operating current1 ... 100 mA

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Operating voltage5 ... 24 V

Off-state current Irmax.0,25 mA

Output voltage0 ... 1 V DC

Type of output2 semiconductor outputs, p-s...

Switching current1 ... 150 mA

Risk time according to EN 60947-5-3-

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Solenoid duty cycle-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Solenoid operating voltage DC-

Fusing0,25 ... 8 A

Test pulsesmax.0,3 ms (Applies for a l...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Test-pulse intervalmin.100 ms

Overtravel5 mm

Extension of risk time according to EN 60947-5-3 per device-

Locking force FZh-

Retention force-

Actuating force10 N

Extraction force20 N

Locking force Fmax-

Guard locking principle-

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5-pin

Housing materialFiber glass reinforced therm...

Ambient temperature-20 ... +55 °C

Installation orientationDoor hinge DIN right

Degree of protectionIP65 (Screwed tight plug co...

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ready delaymax.1 s

B10D0,13 x 10⁶

Detent mechanismSnap-in bolt

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 161206?
The price of 161206 on MQ Automation is $1,280.17. Order now.

Out if stock but available for backorder.

161206 Euchner - MGBS-AR, M23, 1 pushbutton, with escape release, door hinge on right

What can I help you find today?

Recommended parts