161178 Euchner Safety Proximity Sensors

161178 on MQ Automation
Euchner
  • 161178
  • 161178
  • 161178

Part#:161178

Alt. Part#:CET4-AP-CRA-CH-50F-SA-161178

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

161178 Euchner - Non-contact safety switch CET-AP-..., M12

Product Details

  • Weight
    3.086468 lb
  • Series
    CET-AP
  • Product Class
    Safety System
  • Mission time
    20 y
  • PFHD
    3.1 x 10⁻⁹
  • Category
    4
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Performance Level
    PL e
  • Repeat accuracy R
    10 %
  • Discrepancy time
    max.10 ms
  • Turn-on time
    400 ms
  • Risk time according to EN 60947-5-3
    max.400 ms
  • Switching delay from state change
    max.700 ms
  • Off-state current Ir
    max.0,25 mA
  • Output voltage
    0,8xUB ... UB V DC
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Type of output
    p-switching, short circuit-proof
  • Switching current
    1 ... 50 mA
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Connecting cable
    30V DC, 2A (For UL requirement UL category code (CYJV/CYJV7))
  • Solenoid duty cycle
    100 %
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Connection rating
    11 W
  • Fusing
    0,25 ... 8 A
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV (The device tolerates voltage interruptions of up to 5ms)
  • Current consumption
    450 mA
  • Locking force Fmax
    6500 N
  • Locking force FZh
    5000 N (FZH = FMAX/1.3)
  • Guard locking principle
    Open-circuit current principle
  • Approach speed
    max.20 m/min
  • Connection
    1 plug connector M12, 8-pin
  • Switching frequency
    max.0,5 Hz
  • Ready delay
    1 s
  • Ambient temperature
    -20 ... 55 °C
  • Degree of freedom X
    ±5 mm
  • Installation orientation
    Any (Preferably head downward)
  • Housing material
    Stainless steel
  • Degree of freedom Y
    ±5 mm
  • Mechanical life
    1 x 10⁶
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)
  • Weight
    1 kg
  • Degree of freedom Z
    ±4 mm
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 161178 on MQ Automation is $960.24. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With 1 plug connector M12, 8-pin;Multicode;Door monitoring output;Indication of the door position by LED;Escape release, 75 mm long;Approach direction A (delivery state)


Manufacturer warranty

161178 Euchner

$960.24

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$960.24

$960.24 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 161178 with other products

Weight

Series

Product Class

Mission time

PFHD

Category

For the approval acc. to ...

Performance Level

Repeat accuracy R

Discrepancy time

Turn-on time

Risk time according to EN...

Switching delay from stat...

Off-state current Ir

Output voltage

Switching load

Type of output

Switching current

Safety class

Degree of contamination (...

Connecting cable

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Solenoid operating voltag...

Utilization category acc....

Operating voltage DC

Current consumption

Locking force Fmax

Locking force FZh

Guard locking principle

Approach speed

Connection

Switching frequency

Ready delay

Ambient temperature

Degree of freedom X

Installation orientation

Housing material

Degree of freedom Y

Mechanical life

Degree of protection

Degree of freedom Z

Shock and vibration resis...

Additional feature

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Retention force

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

161178
0 in stock
161178
Euchner

161178 Euchner - Non-contact safety switch CET-AP-..., M12

Weight3.086468 lb

SeriesCET-AP

Product ClassSafety System

Mission time20 y

PFHD3.1 x 10⁻⁹

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Performance LevelPL e

Repeat accuracy R10 %

Discrepancy timemax.10 ms

Turn-on time400 ms

Risk time according to EN 60947-5-3max.400 ms

Switching delay from state changemax.700 ms

Off-state current Irmax.0,25 mA

Output voltage0,8xUB ... UB V DC

Switching load24V DC, class 2 (For altern...

Type of outputp-switching, short circuit-p...

Switching current1 ... 50 mA

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Connecting cable30V DC, 2A (For UL requirem...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating11 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption450 mA

Locking force Fmax6500 N

Locking force FZh5000 N (FZH = FMAX/1.3)

Guard locking principleOpen-circuit current princip...

Approach speedmax.20 m/min

Connection1 plug connector M12, 8-pin

Switching frequencymax.0,5 Hz

Ready delay1 s

Ambient temperature-20 ... 55 °C

Degree of freedom X±5 mm

Installation orientationAny (Preferably head downwa...

Housing materialStainless steel

Degree of freedom Y±5 mm

Mechanical life1 x 10⁶

Degree of protectionIP67 (Screwed tight plug co...

Degree of freedom Z±4 mm

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional feature-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Retention force-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Performance LevelPL e

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Switching delay from state change-

Off-state current Irmax.0,25 mA

Output voltage0,8xUB ... UB V DC

Switching load24V DC, class 2 (Alternativ...

Type of outputp-switching, short circuit-p...

Switching current1 ... 50 mA

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Connecting cable-

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Locking force Fmax3900 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Ready delay8 s

Ambient temperature-20 ... +55 °C

Degree of freedom X-

Installation orientationAny

Housing materialDie-cast zinc

Degree of freedom Y-

Mechanical life1 x 10⁶

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Degree of freedom Z-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional featureEscape release actuated by p...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Retention force20 N

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Performance LevelPL e

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3-

Switching delay from state change-

Off-state current Irmax.0,25 mA

Output voltage0 ... 1 V DC

Switching load24V DC, class 2 (Alternativ...

Type of output2 semiconductor outputs, p-s...

Switching current1 ... 150 mA

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Connecting cable-

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Locking force Fmax-

Locking force FZh-

Guard locking principle-

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5-pin

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Ambient temperature-20 ... +55 °C

Degree of freedom X-

Installation orientationDoor hinge DIN right

Housing materialFiber glass reinforced therm...

Degree of freedom Y-

Mechanical life1 x 10⁶

Degree of protectionIP65 (Screwed tight plug co...

Degree of freedom Z-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional feature-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per device-

Extraction force20 N

Overtravel5 mm

Retention force-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 161178?
The price of 161178 on MQ Automation is $960.24. Order now.

Out if stock but available for backorder.

161178 Euchner - Non-contact safety switch CET-AP-..., M12

What can I help you find today?

Recommended parts