159171 Euchner Safety Locking Systems

159171 on MQ Automation
Euchner
  • 159171
  • 159171
  • 159171

Part#:159171

Alt. Part#:MGBS-P-L1-AR-U-R-AZE-SH-159171

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

Product description

159171 Euchner - MGBS-AR, M23, emergency stop, 2 pushbuttons, door hinge on right

Product Details

  • Weight
    4.71568218 lb
  • Series
    MGBS-AR
  • Product Class
    Safety System
  • Mission time
    20 y
  • B10D
    0,13 x 10⁶
  • Performance Level
    PL e
  • Category
    4
  • Version
    Emergency stop
  • Switching element
    2 pos. driven NC
  • Repeat accuracy R
    10 %
  • PFHD
    4.1 x 10 ⁻⁹
  • Additional feature
    Incl. cover set ID. No. 120344
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Power supply
    24 V
  • Operating current
    1 ... 50 mA
  • Operating voltage
    UB V
  • Turn-on time
    max.400 ms
  • Discrepancy time
    max.10 ms In acc. with EN IEC 60947-5-3
  • Off-state current Ir
    max.0,25 mA
  • Output voltage
    UB-1,5 ... UB V DC
  • Switching current
    1 ... 150 mA
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Switching load
    24V DC, class 2 (Alternatively see operating instructions)
  • Safety class
    III
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Solenoid duty cycle
    100 %
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Connection rating
    6 W
  • Fusing
    0,25 ... 8 A
  • Rated insulation voltage Ui
    50 V
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Test-pulse interval
    min.140 ms
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Overtravel
    5 mm
  • Test pulses
    max.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Current consumption
    40 mA
  • Actuating force
    10 N
  • Extraction force
    20 N
  • Locking force FZh
    3000 N (Fzh = Fmax/1.3 Depending on the actuator used)
  • Retention force
    20 N
  • Locking force Fmax
    3900 N
  • Connection
    1 plug connector M23, 19-pin, RC18
  • Approach speed
    max.20 m/min
  • Guard locking principle
    Closed-circuit current principle
  • Housing material
    Die-cast zinc
  • Ready delay
    8 s
  • Mechanical life
    1 x 10⁶
  • Switching frequency
    max.0,5 Hz
  • Ambient temperature
    -20 ... +55 °C
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Degree of protection
    IP65 (Screwed tight plug connector/mating component)
  • Installation orientation
    Door hinge DIN right
  • Weight
    1,5 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 159171 on MQ Automation is $1,313.26. Order now.


About the product

Locking module (order handle module separately);Adjustable door hinge; factory setting: right;Series connection possible (up to 20 AR devices in series);Short circuit monitoring;2 safety outputs (semiconductor outputs);Up to category 4 / PL e according to EN ISO 13849-1;Emergency stop;2 pushbuttons (illuminated);With plug connector M23;Unicode;Door position monitoring output


Manufacturer warranty

159171 Euchner

$1,313.26

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,313.26

$1,313.26 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 159171 with other products

Weight

Series

Product Class

Mission time

B10D

Performance Level

Category

Version

Switching element

Repeat accuracy R

PFHD

Additional feature

For the approval acc. to ...

Power supply

Operating current

Operating voltage

Turn-on time

Discrepancy time

Off-state current Ir

Output voltage

Switching current

Type of output

Risk time according to EN...

Switching load

Safety class

Rated impulse withstand v...

Degree of contamination (...

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Rated insulation voltage ...

Solenoid operating voltag...

Utilization category acc....

Test-pulse interval

Operating voltage DC

Overtravel

Test pulses

Current consumption

Actuating force

Extraction force

Locking force FZh

Retention force

Locking force Fmax

Connection

Approach speed

Guard locking principle

Housing material

Ready delay

Mechanical life

Switching frequency

Ambient temperature

Shock and vibration resis...

Degree of protection

Installation orientation

Extension of risk time ac...

Detent mechanism

Selected product

159171
0 in stock
159171
Euchner

159171 Euchner - MGBS-AR, M23, emergency stop, 2 pushbuttons, door hinge on right

Weight4.71568218 lb

SeriesMGBS-AR

Product ClassSafety System

Mission time20 y

B10D0,13 x 10⁶

Performance LevelPL e

Category4

VersionEmergency stop

Switching element2 pos. driven NC

Repeat accuracy R10 %

PFHD4.1 x 10 ⁻⁹

Additional featureIncl. cover set ID. No. 1203...

For the approval acc. to UL the following appliesOperation only with UL class...

Power supply24 V

Operating current1 ... 50 mA

Operating voltageUB V

Turn-on timemax.400 ms

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Output voltageUB-1,5 ... UB V DC

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Risk time according to EN 60947-5-3max.260 ms

Switching load24V DC, class 2 (Alternativ...

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Rated insulation voltage Ui50 V

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test-pulse intervalmin.140 ms

Operating voltage DC24 V DC -15% ... 15% Rev...

Overtravel5 mm

Test pulsesmax.1,0 ms (Applies for a l...

Current consumption40 mA

Actuating force10 N

Extraction force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Retention force20 N

Locking force Fmax3900 N

Connection1 plug connector M23, 19-pin...

Approach speedmax.20 m/min

Guard locking principleClosed-circuit current princ...

Housing materialDie-cast zinc

Ready delay8 s

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of protectionIP65 (Screwed tight plug co...

Installation orientationDoor hinge DIN right

Extension of risk time according to EN 60947-5-3 per device-

Detent mechanism-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

B10D-

Performance LevelPL e

Category4

Version-

Switching element-

Repeat accuracy R10 %

PFHD4.1 x 10 ⁻⁹

Additional featureEscape release actuated by p...

For the approval acc. to UL the following appliesOperation only with UL class...

Power supply-

Operating current-

Operating voltage-

Turn-on timemax.400 ms

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Output voltage0,8xUB ... UB V DC

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Risk time according to EN 60947-5-3max.260 ms

Switching load24V DC, class 2 (Alternativ...

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Rated insulation voltage Ui50 V

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test-pulse intervalmin.140 ms

Operating voltage DC24 V DC -15% ... 15% Rev...

Overtravel5 mm

Test pulsesmax.1,0 ms (Applies for a l...

Current consumption40 mA

Actuating force10 N

Extraction force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Retention force20 N

Locking force Fmax3900 N

Connection2 plug connectors M12, 5 and...

Approach speedmax.20 m/min

Guard locking principleClosed-circuit current princ...

Housing materialDie-cast zinc

Ready delay8 s

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Installation orientationAny

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Detent mechanism-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

B10D0,13 x 10⁶

Performance LevelPL e

Category4

VersionEmergency stop

Switching element2 pos. driven NC

Repeat accuracy R10 %

PFHD4.1 x 10 ⁻⁹

Additional feature-

For the approval acc. to UL the following appliesOperation only with UL class...

Power supply-

Operating current1 ... 100 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Output voltage0 ... 1 V DC

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Risk time according to EN 60947-5-3-

Switching load24V DC, class 2 (Alternativ...

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Rated insulation voltage Ui50 V

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test-pulse intervalmin.100 ms

Operating voltage DC24 V DC -15% ... 15% Rev...

Overtravel5 mm

Test pulsesmax.0,3 ms (Applies for a l...

Current consumption40 mA

Actuating force10 N

Extraction force20 N

Locking force FZh-

Retention force-

Locking force Fmax-

Connection2 plug connectors M12, 5-pin

Approach speedmax.20 m/min

Guard locking principle-

Housing materialFiber glass reinforced therm...

Ready delaymax.1 s

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of protectionIP65 (Screwed tight plug co...

Installation orientationDoor hinge DIN right

Extension of risk time according to EN 60947-5-3 per device-

Detent mechanismSnap-in bolt

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 159171?
The price of 159171 on MQ Automation is $1,313.26. Order now.

Out if stock but available for backorder.

159171 Euchner - MGBS-AR, M23, emergency stop, 2 pushbuttons, door hinge on right

What can I help you find today?

Recommended parts