128103 Euchner Safety Switches

128103 on MQ Automation
Euchner

Part#:128103

Alt. Part#:CEM-I2-AY-U-C40-SA-128103

Manufacturer:Euchner

Category:Safety Switches

Product Lifecycle:Active

Product description

128103 Euchner - Transponder-coded safety switch CEM-AY-C40

Product Details

  • Weight
    1.65566962 lb
  • Series
    CEM-AY-C40
  • Product Class
    Safety System
  • PFHD
    4.5 x 10⁻⁹
  • Mission time
    20 y
  • Category
    4
  • Performance Level
    PL e
  • Center offset
    -5 ... +5 mm (In all directions)
  • Assured release distance Sar
    18 mm
  • Output voltage
    UB - 1,5 ... UB V DC
  • Off-state current Ir
    max.0,25 mA
  • Utilization category acc. to EN 60947-5-2
    DC-13 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Switching current
    1 ... 150 mA
  • Switching frequency, electrical
    0,5 Hz
  • Discrepancy time
    max.10 ms
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Safety class
    III
  • Turn-on time
    700 ... 2500 ms (Max. value, with active guard locking)
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated insulation voltage Ui
    30 V
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • EMC protection requirements
    In acc. with EN 60947-5-3
  • Test pulses
    max.0,8 ms
  • Rated conditional short-circuit current
    100 A
  • Ready delay
    12 s
  • Connection
    Plug connector M12, 8-pin
  • Fusing
    1 A
  • Current consumption
    350 mA (Monitoring outputs not loaded)
  • Locking force Fmax
    600 N (The device signals if the locking force drops below 400N.)
  • Operating voltage
    24 V -15% ... +15% (PELV)
  • Adhesive force
    0, ca. 30, ca. 50 N
  • Weight
    0,64 kg
  • Material
    Plastic (PBT)
  • Degree of protection
    IP65/IP67 (Screwed tight with the corresponding mating connector)
  • Installation orientation
    Any
  • Mechanical life
    1 x 10⁶
  • Tightening torque
    4 Nm
  • Ambient temperature
    -20 ... 55 °C
  • Housing material
    Aluminum
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 128103 on MQ Automation is $863.06. Order now.


About the product

Safety switches with guard locking for process protection and integrated evaluation electronics;Solenoid with locking force 600 N;Adhesive-force adjustment in 3 levels;Short circuit monitoring;2 safety outputs (semiconductor outputs);Up to category 4 / PL e according to EN ISO 13849-1 for door position monitoring;With plug connector M12;Unicode;Door monitoring output


Manufacturer warranty

128103 Euchner

$863.06

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$863.06

$863.06 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 128103 with other products

Weight

Series

Product Class

PFHD

Mission time

Category

Performance Level

Center offset

Assured release distance Sar

Output voltage

Off-state current Ir

Utilization category acc. to EN 60947-5-2

Switching current

Switching frequency, electrical

Discrepancy time

Type of output

Risk time according to EN 60947-5-3

Safety class

Turn-on time

Degree of contamination (external, according to EN 60947-1)

Rated insulation voltage Ui

Rated impulse withstand voltage Uimp

EMC protection requirements

Test pulses

Rated conditional short-circuit current

Ready delay

Connection

Fusing

Current consumption

Locking force Fmax

Operating voltage

Adhesive force

Weight

Material

Degree of protection

Installation orientation

Mechanical life

Tightening torque

Ambient temperature

Housing material

Shock and vibration resistance

Mission time

PFHD

Category

Performance Level

For the approval acc. to UL the following applies

Additional feature

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Switching current

Type of output

Switching load

Risk time according to EN 60947-5-3

Safety class

Degree of contamination (external, according to EN 60947-1)

Solenoid duty cycle

EMC protection requirements

Rated impulse withstand voltage Uimp

Rated insulation voltage Ui

Connection rating

Fusing

Solenoid operating voltage DC

Operating voltage DC

Utilization category acc. to EN 60947-5-2

Test pulses

Test-pulse interval

Actuating force

Extension of risk time according to EN 60947-5-3 per device

Current consumption

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Connection

Locking force FZh

Guard locking principle

Mechanical life

Ambient temperature

Degree of protection

Switching frequency

Weight

Ready delay

Installation orientation

Shock and vibration resistance

Housing material

Assured operating distance Sao

Switching hysteresis

Assured release distance Sar

Operating distance

Mission time

PFHD

For the approval acc. to UL the following applies

Additional feature

Performance Level

Repeat accuracy R

Category

Discrepancy time

Off-state current Ir

Rated conditional short-circuit current

Test-pulse interval

Utilization category acc. to EN 60947-5-2

Test pulses

Switching current

Output voltage

Type of output

Turn-on time

Risk time according to EN 60947-5-3

Safety class

EMC protection requirements

Degree of contamination (external, according to EN 60947-1)

Rated impulse withstand voltage Uimp

Rated insulation voltage Ui

Fusing

Operating voltage DC

Switching frequency

Extension of risk time according to EN 60947-5-3 per device

Current consumption

Connection

Ready delay

Tightening torque

Installation orientation

Mounting method

Shock and vibration resistance

Mounting distance

Cable ambient temperature (static)

Cable ambient temperature (dynamic)

Degree of protection

Dynamic bending radius

Material

Housing material

Static bending radius

Weight

Selected product

128103
0 in stock
128103
Euchner

128103 Euchner - Transponder-coded safety switch CEM-AY-C40

Weight1.65566962 lb

SeriesCEM-AY-C40

Product ClassSafety System

PFHD4.5 x 10⁻⁹

Mission time20 y

Category4

Performance LevelPL e

Center offset-5 ... +5 mm (In all directions)

Assured release distance Sar18 mm

Output voltageUB - 1,5 ... UB V DC

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-2DC-13 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Switching current1 ... 150 mA

Switching frequency, electrical0,5 Hz

Discrepancy timemax.10 ms

Type of outputSemiconductor outputs, p-switching, short circuit-proof

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Turn-on time700 ... 2500 ms (Max. value, with active guard locking)

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui30 V

Rated impulse withstand voltage Uimp0,5 kV

EMC protection requirementsIn acc. with EN 60947-5-3

Test pulsesmax.0,8 ms

Rated conditional short-circuit current100 A

Ready delay12 s

ConnectionPlug connector M12, 8-pin

Fusing1 A

Current consumption350 mA (Monitoring outputs not loaded)

Locking force Fmax600 N (The device signals if the locking force drops below 400N.)

Operating voltage24 V -15% ... +15% (PELV)

Adhesive force0, ca. 30, ca. 50 N

Weight0,64 kg

MaterialPlastic (PBT)

Degree of protectionIP65/IP67 (Screwed tight with the corresponding mating connector)

Installation orientationAny

Mechanical life1 x 10⁶

Tightening torque4 Nm

Ambient temperature-20 ... 55 °C

Housing materialAluminum

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Locking force FZh-

Guard locking principle-

Mechanical life-

Ambient temperature-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Installation orientation-

Shock and vibration resistance-

Housing material-

Assured operating distance Sao-

Switching hysteresis-

Assured release distance Sar-

Operating distance-

Mission time-

PFHD-

For the approval acc. to UL the following applies-

Additional feature-

Performance Level-

Repeat accuracy R-

Category-

Discrepancy time-

Off-state current Ir-

Rated conditional short-circuit current-

Test-pulse interval-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Switching current-

Output voltage-

Type of output-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

EMC protection requirements-

Degree of contamination (external, according to EN 60947-1)-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Fusing-

Operating voltage DC-

Switching frequency-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Connection-

Ready delay-

Tightening torque-

Installation orientation-

Mounting method-

Shock and vibration resistance-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Degree of protection-

Dynamic bending radius-

Material-

Housing material-

Static bending radius-

Weight-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

PFHD-

Mission time-

Category-

Performance Level-

Center offset-

Assured release distance Sar-

Output voltage-

Off-state current Ir-

Utilization category acc. to EN 60947-5-2-

Switching current-

Switching frequency, electrical-

Discrepancy time-

Type of output-

Risk time according to EN 60947-5-3-

Safety class-

Turn-on time-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

EMC protection requirements-

Test pulses-

Rated conditional short-circuit current-

Ready delay-

Connection-

Fusing-

Current consumption-

Locking force Fmax-

Operating voltage-

Adhesive force-

Weight-

Material-

Degree of protection-

Installation orientation-

Mechanical life-

Tightening torque-

Ambient temperature-

Housing material-

Shock and vibration resistance-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

Additional featureEscape release actuated by pushing

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN IEC 60947-5-3

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-proof

Switching load24V DC, class 2 (Alternatively see operating instructions)

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Operating voltage DC24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Test pulsesmax.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumption40 mA

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Connection2 plug connectors M12, 5 and 8-pin

Locking force FZh3000 N (Fzh = Fmax/1.3 Depending on the actuator used)

Guard locking principleClosed-circuit current principle

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed tight plug connector/mating component)

Switching frequencymax.0,5 Hz

Weight0,42 kg

Ready delay8 s

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialDie-cast zinc

Assured operating distance Sao-

Switching hysteresis-

Assured release distance Sar-

Operating distance-

Mission time-

PFHD-

For the approval acc. to UL the following applies-

Additional feature-

Performance Level-

Repeat accuracy R-

Category-

Discrepancy time-

Off-state current Ir-

Rated conditional short-circuit current-

Test-pulse interval-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Switching current-

Output voltage-

Type of output-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

EMC protection requirements-

Degree of contamination (external, according to EN 60947-1)-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Fusing-

Operating voltage DC-

Switching frequency-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Connection-

Ready delay-

Tightening torque-

Installation orientation-

Mounting method-

Shock and vibration resistance-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Degree of protection-

Dynamic bending radius-

Material-

Housing material-

Static bending radius-

Weight-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SeriesCES-AR

Product ClassSafety System

PFHD-

Mission time-

Category-

Performance Level-

Center offset-

Assured release distance Sar-

Output voltage-

Off-state current Ir-

Utilization category acc. to EN 60947-5-2-

Switching current-

Switching frequency, electrical-

Discrepancy time-

Type of output-

Risk time according to EN 60947-5-3-

Safety class-

Turn-on time-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

EMC protection requirements-

Test pulses-

Rated conditional short-circuit current-

Ready delay-

Connection-

Fusing-

Current consumption-

Locking force Fmax-

Operating voltage-

Adhesive force-

Weight-

Material-

Degree of protection-

Installation orientation-

Mechanical life-

Tightening torque-

Ambient temperature-

Housing material-

Shock and vibration resistance-

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Locking force FZh-

Guard locking principle-

Mechanical life-

Ambient temperature-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Installation orientation-

Shock and vibration resistance-

Housing material-

Assured operating distance Sao6

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance11 mm

Mission time20

PFHD4.1 x 10⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures

Additional featureRubber support included

Performance LevelPL e

Repeat accuracy R≤ 10

Category4

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)

Test pulsesmax.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Switching currentmax.50 mA

Output voltage0,8 x UB ... UB V DC

Type of outputSemiconductor output, p-switching, short circuit-proof

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui300 V

Fusing0,25 ... 8 A

Operating voltage DC24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV

Switching frequencymax.1 Hz

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumptionmax.35 mA (Without taking into account the load currents on the monitoring output and the safety outputs)

ConnectionConnection cable PUR, length 1m with plug connector M12 8-pin

Ready delay10 s

Tightening torquemax.0,8 Nm

Installation orientationAny

Mounting methodSurface mounting on metal

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.80 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Degree of protectionIP67

Dynamic bending radius10 x cable diameter

MaterialNBR 80 ±5 Shore

Housing materialPlastic, PBT

Static bending radius5 x cable diameter

Weight0,08 kg

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 128103?
The price of 128103 on MQ Automation is $863.06. Order now.

Out if stock but available for backorder.

128103 Euchner - Transponder-coded safety switch CEM-AY-C40

Similar products from: Safety Switches

What can I help you find today?

Recommended parts