Product description

126912 Euchner - Transponder-coded safety switch CTP-AP, M12, with escape release

Product Details

  • Weight
    1.763696 lb
  • Series
    CTP-AP
  • Product Class
    Safety System
  • PFHD
    4.1 x 10 ⁻⁹
  • Mission time
    20 y
  • Category
    4
  • Performance Level
    PL e
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Additional feature
    Escape release actuated by pushing
  • Repeat accuracy R
    10 %
  • Discrepancy time
    max.10 ms In acc. with EN IEC 60947-5-3
  • Output voltage
    UB-1,5 ... UB V DC
  • Switching current
    1 ... 150 mA
  • Turn-on time
    max.400 ms
  • Off-state current Ir
    max.0,25 mA
  • Switching load
    24V DC, class 2 (Alternatively see operating instructions)
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Rated insulation voltage Ui
    50 V
  • Safety class
    III
  • Solenoid duty cycle
    100 %
  • Connection rating
    6 W
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Fusing
    0,25 ... 8 A
  • Current consumption
    400 mA
  • Actuating force
    10 N
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Test pulses
    max.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Test-pulse interval
    min.100 ms
  • Overtravel
    5 mm
  • Retention force
    20 N
  • Extraction force
    20 N
  • Locking force FZh
    3000 N (Fzh = Fmax/1.3 Depending on the actuator used)
  • Approach speed
    max.20 m/min
  • Guard locking principle
    Closed-circuit current principle
  • Locking force Fmax
    3900 N
  • Degree of protection
    IP67/IP69/IP69K (Screwed tight plug connector/mating component)
  • Switching frequency
    max.0,5 Hz
  • Ambient temperature
    -20 ... +55 °C
  • Connection
    1 plug connector M12, 8-pin
  • Mechanical life
    1 x 10⁶
  • Ready delay
    max.1 s
  • Installation orientation
    Any
  • Weight
    0,42 kg
  • Housing material
    Fiber glass reinforced thermoplastic
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 126912 on MQ Automation is $902.04. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Short circuit monitoring;2 safety outputs (semiconductor outputs);Up to category 4 / PL e according to EN ISO 13849-1;With plug connector M12;Unicode;Door monitoring output;With escape release;Approach directions A, B and C (delivery state)


This item can ship in 3-5 days!

Manufacturer warranty

126912 Euchner

$902.04

Your price can be lower.
Log in or Create account to check your discount

Stock:

8

Select Qty:

$902.04

$902.04 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 126912 with other products

Weight

Series

Product Class

PFHD

Mission time

Category

Performance Level

For the approval acc. to UL the following applies

Additional feature

Repeat accuracy R

Discrepancy time

Output voltage

Switching current

Turn-on time

Off-state current Ir

Switching load

Type of output

Degree of contamination (external, according to EN 60947-1)

EMC protection requirements

Rated insulation voltage Ui

Safety class

Solenoid duty cycle

Connection rating

Solenoid operating voltage DC

Rated impulse withstand voltage Uimp

Fusing

Current consumption

Actuating force

Operating voltage DC

Test pulses

Utilization category acc. to EN 60947-5-2

Test-pulse interval

Overtravel

Retention force

Extraction force

Locking force FZh

Approach speed

Guard locking principle

Locking force Fmax

Degree of protection

Switching frequency

Ambient temperature

Connection

Mechanical life

Ready delay

Installation orientation

Weight

Housing material

Shock and vibration resistance

Mission time

PFHD

Category

Performance Level

For the approval acc. to UL the following applies

Additional feature

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Switching current

Type of output

Switching load

Risk time according to EN 60947-5-3

Safety class

Degree of contamination (external, according to EN 60947-1)

Solenoid duty cycle

EMC protection requirements

Rated impulse withstand voltage Uimp

Rated insulation voltage Ui

Connection rating

Fusing

Solenoid operating voltage DC

Operating voltage DC

Utilization category acc. to EN 60947-5-2

Test pulses

Test-pulse interval

Actuating force

Extension of risk time according to EN 60947-5-3 per device

Current consumption

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Connection

Locking force FZh

Guard locking principle

Mechanical life

Ambient temperature

Degree of protection

Switching frequency

Weight

Ready delay

Installation orientation

Shock and vibration resistance

Housing material

B10D

Mission time

PFHD

Performance Level

Category

For the approval acc. to UL the following applies

Version

Operating current

Switching element

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Safety class

Turn-on time

Switching load

EMC protection requirements

Output voltage

Degree of contamination (external, according to EN 60947-1)

Rated insulation voltage Ui

Rated impulse withstand voltage Uimp

Connection rating

Utilization category acc. to EN 60947-5-2

Fusing

Current consumption

Operating voltage DC

Overtravel

Test-pulse interval

Ambient temperature

Extraction force

Test pulses

Actuating force

Installation orientation

Mechanical life

Shock and vibration resistance

Housing material

Approach speed

Degree of protection

Switching frequency

Weight

Ready delay

Connection

Selected product

126912
8 in stock
126912
Euchner

126912 Euchner - Transponder-coded safety switch CTP-AP, M12, with escape release

Weight1.763696 lb

SeriesCTP-AP

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

Additional featureEscape release actuated by pushing

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN IEC 60947-5-3

Output voltageUB-1,5 ... UB V DC

Switching current1 ... 150 mA

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching load24V DC, class 2 (Alternatively see operating instructions)

Type of output2 semiconductor outputs, p-switching, short circuit-proof

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Rated insulation voltage Ui50 V

Safety classIII

Solenoid duty cycle100 %

Connection rating6 W

Solenoid operating voltage DC24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Rated impulse withstand voltage Uimp0,5 kV

Fusing0,25 ... 8 A

Current consumption400 mA

Actuating force10 N

Operating voltage DC24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Test pulsesmax.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Test-pulse intervalmin.100 ms

Overtravel5 mm

Retention force20 N

Extraction force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Depending on the actuator used)

Approach speedmax.20 m/min

Guard locking principleClosed-circuit current principle

Locking force Fmax3900 N

Degree of protectionIP67/IP69/IP69K (Screwed tight plug connector/mating component)

Switching frequencymax.0,5 Hz

Ambient temperature-20 ... +55 °C

Connection1 plug connector M12, 8-pin

Mechanical life1 x 10⁶

Ready delaymax.1 s

Installation orientationAny

Weight0,42 kg

Housing materialFiber glass reinforced thermoplastic

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Locking force FZh-

Guard locking principle-

Mechanical life-

Ambient temperature-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Installation orientation-

Shock and vibration resistance-

Housing material-

B10D-

Mission time-

PFHD-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Fusing-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Ambient temperature-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Mechanical life-

Shock and vibration resistance-

Housing material-

Approach speed-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Connection-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

PFHD-

Mission time-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Switching current-

Turn-on time-

Off-state current Ir-

Switching load-

Type of output-

Degree of contamination (external, according to EN 60947-1)-

EMC protection requirements-

Rated insulation voltage Ui-

Safety class-

Solenoid duty cycle-

Connection rating-

Solenoid operating voltage DC-

Rated impulse withstand voltage Uimp-

Fusing-

Current consumption-

Actuating force-

Operating voltage DC-

Test pulses-

Utilization category acc. to EN 60947-5-2-

Test-pulse interval-

Overtravel-

Retention force-

Extraction force-

Locking force FZh-

Approach speed-

Guard locking principle-

Locking force Fmax-

Degree of protection-

Switching frequency-

Ambient temperature-

Connection-

Mechanical life-

Ready delay-

Installation orientation-

Weight-

Housing material-

Shock and vibration resistance-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

Additional featureEscape release actuated by pushing

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN IEC 60947-5-3

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-proof

Switching load24V DC, class 2 (Alternatively see operating instructions)

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Operating voltage DC24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Test pulsesmax.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumption40 mA

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Connection2 plug connectors M12, 5 and 8-pin

Locking force FZh3000 N (Fzh = Fmax/1.3 Depending on the actuator used)

Guard locking principleClosed-circuit current principle

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed tight plug connector/mating component)

Switching frequencymax.0,5 Hz

Weight0,42 kg

Ready delay8 s

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialDie-cast zinc

B10D-

Mission time-

PFHD-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Fusing-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Ambient temperature-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Mechanical life-

Shock and vibration resistance-

Housing material-

Approach speed-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Connection-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

PFHD-

Mission time-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Switching current-

Turn-on time-

Off-state current Ir-

Switching load-

Type of output-

Degree of contamination (external, according to EN 60947-1)-

EMC protection requirements-

Rated insulation voltage Ui-

Safety class-

Solenoid duty cycle-

Connection rating-

Solenoid operating voltage DC-

Rated impulse withstand voltage Uimp-

Fusing-

Current consumption-

Actuating force-

Operating voltage DC-

Test pulses-

Utilization category acc. to EN 60947-5-2-

Test-pulse interval-

Overtravel-

Retention force-

Extraction force-

Locking force FZh-

Approach speed-

Guard locking principle-

Locking force Fmax-

Degree of protection-

Switching frequency-

Ambient temperature-

Connection-

Mechanical life-

Ready delay-

Installation orientation-

Weight-

Housing material-

Shock and vibration resistance-

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Locking force FZh-

Guard locking principle-

Mechanical life-

Ambient temperature-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Installation orientation-

Shock and vibration resistance-

Housing material-

B10D0,13 x 10⁶

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN IEC 60947-5-3

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-switching, short circuit-proof

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternatively see operating instructions)

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Output voltage0 ... 1 V DC

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Fusing0,25 ... 8 A

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Overtravel5 mm

Test-pulse intervalmin.100 ms

Ambient temperature-20 ... +55 °C

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Actuating force10 N

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialFiber glass reinforced thermoplastic

Approach speedmax.20 m/min

Degree of protectionIP65 (Screwed tight plug connector/mating component)

Switching frequencymax.0,5 Hz

Weight1,25 kg

Ready delaymax.1 s

Connection2 plug connectors M12, 5-pin

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 126912?
The price of 126912 on MQ Automation is $902.04. Order now.

Out if stock but available for backorder.

126912 Euchner - Transponder-coded safety switch CTP-AP, M12, with escape release

Similar products from: Safety Switches

What can I help you find today?

Recommended parts