124820 Euchner - Evaluation module with control and bus module MGB-...-PN with 11 controls and indicators, 7/8" and M12 plugs, RC12

Product Details

  • Weight
    10.14566124 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Diagnostic Coverage (DC)
    99
  • B10D
    0,13 x 10⁶
  • PFHD
    3.91 x 10⁻⁸
  • Performance Level
    PL e
  • Product version number
    V3.30.10
  • Category
    4
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Version
    Illuminated push buttons
  • Color
    white
  • Switching element
    1NO
  • Safety class
    III
  • Assignment diagram
    L0
  • Fusing
    min.1 A Slow blow
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Assured release distance Sar
    max.65 mm
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Operating voltage DC
    24 V DC -15% ... +10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Transponder coding
    Unicode
  • Current consumption
    max.500 mA
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Rated insulation voltage Ui
    75 V
  • Connection
    Plug connector RC12 (X14)
  • Guard locking principle
    Closed-circuit current principle
  • Locking force FZh
    2000 N
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Mechanical life
    0,1 x 10⁶
  • Ambient temperature
    -20 ... 55 °C
  • Switching frequency
    0,25 Hz
  • Weight
    4,05 kg
  • Degree of protection
    IP54
  • Reaction time
    max.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Installation orientation
    Door hinge DIN left
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 124820 on MQ Automation is $4,059.07. Order now.


About the product

Guard locking with guard lock monitoring;Emergency stop according to ISO 13850, illuminated;9 illuminated pushbuttons;Operating mode selector;Connection via 7/8&quot; and M12 plugs;including terminal plug for stack light (M12, 5-pin);including terminal plug for enabling switch (RC12, 12-pin);Pre-assembled on mounting plates;Integrated Profinet RT switch;Unicode


Manufacturer warranty

124820 Euchner

$4,059.07

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$4,059.07

$4,059.07 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 124820 with other products

Weight

Series

Product Class

Mission time

Safety Integrity Level

Diagnostic Coverage (DC)

B10D

PFHD

Performance Level

Product version number

Category

Safety data protocol

Version

Color

Switching element

Safety class

Assignment diagram

Fusing

Bus data protocol

Assured release distance ...

Degree of contamination (...

Auxiliary voltage DC

Operating voltage DC

Connecting cable

Transponder coding

Current consumption

Maximum feed-in current i...

Rated insulation voltage ...

Connection

Guard locking principle

Locking force FZh

Rated impulse withstand v...

EMC protection requiremen...

Shock and vibration resis...

Mechanical life

Ambient temperature

Switching frequency

Degree of protection

Reaction time

Installation orientation

Housing material

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Additional feature

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

124820
0 in stock
124820
Euchner

124820 Euchner - Evaluation module with control and bus module MGB-...-PN with 11 controls and indic...

Weight10.14566124 lb

SeriesSpare parts

Product ClassAccessories

Mission time20

Safety Integrity LevelSIL 3 (EN 62061:2005)

Diagnostic Coverage (DC)99

B10D0,13 x 10⁶

PFHD3.91 x 10⁻⁸

Performance LevelPL e

Product version numberV3.30.10

Category4

Safety data protocolProfisafe (IEC 61784-3-3)

VersionIlluminated push buttons

Colorwhite

Switching element1NO

Safety classIII

Assignment diagramL0

Fusingmin.1 A Slow blow

Bus data protocolProfinet (IEC 61158 type 10)

Assured release distance Sarmax.65 mm

Degree of contamination (external, according to EN 60947-1)3

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Operating voltage DC24 V DC -15% ... +10% ((R...

Connecting cableProfinet I/O cable, at least...

Transponder codingUnicode

Current consumptionmax.500 mA

Maximum feed-in current in the connection blockmax.4000 mA

Rated insulation voltage Ui75 V

ConnectionPlug connector RC12 (X14)

Guard locking principleClosed-circuit current princ...

Locking force FZh2000 N

Rated impulse withstand voltage Uimp0,5 kV

EMC protection requirementsIn accordance with EN 61000-...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mechanical life0,1 x 10⁶

Ambient temperature-20 ... 55 °C

Switching frequency0,25 Hz

Degree of protectionIP54

Reaction timemax.550 ms Switch-off time...

Installation orientationDoor hinge DIN left

Housing materialReinforced plastic, die-cast...

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Safety Integrity Level-

Diagnostic Coverage (DC)-

B10D0,13 x 10⁶

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Product version number-

Category4

Safety data protocol-

VersionEmergency stop

Color-

Switching element2 pos. driven NC

Safety classIII

Assignment diagram-

Fusing0,25 ... 8 A

Bus data protocol-

Assured release distance Sar-

Degree of contamination (external, according to EN 60947-1)3

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Connecting cable-

Transponder coding-

Current consumption40 mA

Maximum feed-in current in the connection block-

Rated insulation voltage Ui50 V

Connection2 plug connectors M12, 5-pin

Guard locking principle-

Locking force FZh-

Rated impulse withstand voltage Uimp0,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Switching frequencymax.0,5 Hz

Degree of protectionIP65 (Screwed tight plug co...

Reaction time-

Installation orientationDoor hinge DIN right

Housing materialFiber glass reinforced therm...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Safety Integrity Level-

Diagnostic Coverage (DC)-

B10D-

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Product version number-

Category4

Safety data protocol-

Version-

Color-

Switching element-

Safety classIII

Assignment diagram-

Fusing0,25 ... 8 A

Bus data protocol-

Assured release distance Sar-

Degree of contamination (external, according to EN 60947-1)3

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Connecting cable-

Transponder coding-

Current consumption40 mA

Maximum feed-in current in the connection block-

Rated insulation voltage Ui50 V

Connection2 plug connectors M12, 5 and...

Guard locking principleClosed-circuit current princ...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Rated impulse withstand voltage Uimp0,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Switching frequencymax.0,5 Hz

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Reaction time-

Installation orientationAny

Housing materialDie-cast zinc

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 124820?
The price of 124820 on MQ Automation is $4,059.07. Order now.

Out if stock but available for backorder.

124820 Euchner - Evaluation module with control and bus module MGB-...-PN with 11 controls and indicators, 7/8&quot; and M12 plugs, RC12

What can I help you find today?

Recommended parts