122814 Euchner Electronic Components

122814 on MQ Automation
Euchner

Part#:122814

Manufacturer:Euchner

Category:Electronic Components

Product Lifecycle:Active

Get a quick Quote!

Transponder-coded safety switch CTP-AR, 2 x M12

About the manufacturer: Euchner is one of the manufacturers that offers Electronic Components that you can order at MQ Automation site. As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Check out the 122814 Euchner price in the box on the right side or send a quick quote.

Product Details

  • Mission time
    20 y
  • Category
    4
  • PFHD
    4.1 x 10 ⁻⁹
  • Performance Level
    PL e
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Repeat accuracy R
    10 %
  • Discrepancy time
    max.10 ms In acc. with EN IEC 60947-5-3
  • Off-state current Ir
    max.0,25 mA
  • Output voltage
    0,8xUB ... UB V DC
  • Turn-on time
    max.400 ms
  • Switching current
    1 ... 50 mA
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Switching load
    24V DC, class 2 (Alternatively see operating instructions)
  • Type of output
    p-switching, short circuit-proof
  • Solenoid duty cycle
    100 %
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Connection rating
    6 W
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Fusing
    0,25 ... 8 A
  • Rated insulation voltage Ui
    50 V
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Current consumption
    40 mA
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Test pulses
    max.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Overtravel
    5 mm
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Test-pulse interval
    min.140 ms
  • Actuating force
    10 N
  • Retention force
    20 N
  • Extraction force
    20 N
  • Locking force FZh
    3000 N (Fzh = Fmax/1.3 Depending on the actuator used)
  • Locking force Fmax
    3900 N
  • Guard locking principle
    Open-circuit current principle
  • Approach speed
    max.20 m/min
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Ready delay
    8 s
  • Switching frequency
    max.0,5 Hz
  • Installation orientation
    Any
  • Mechanical life
    1 x 10⁶
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Ambient temperature
    -20 ... +55 °C
  • Degree of protection
    IP67/IP69/IP69K (Screwed tight plug connector/mating component)
  • Weight
    0,42 kg
  • Housing material
    Die-cast zinc

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

$772.00

Select Qty:

$772.00

$772.00 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Relevant products

What can I help you find today?

Recommended parts