122812 Euchner Electronic Components


Part#:122812
Manufacturer:Euchner
Category:Electronic Components
Product Lifecycle:Active
Get a quick Quote!
Transponder-coded safety switch CTP-AR, 2 x M12
About the manufacturer: Euchner is one of the manufacturers that offers Electronic Components that you can order at MQ Automation site. As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Check out the 122812 Euchner price in the box on the right side or send a quick quote.
Product Details
- PFHD 4.1 x 10 ⁻⁹
- Mission time 20 y
- Performance Level PL e
- Category 4
- For the approval acc. to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
- Discrepancy time max.10 ms In acc. with EN IEC 60947-5-3
- Repeat accuracy R 10 %
- Turn-on time max.400 ms
- Off-state current Ir max.0,25 mA
- Switching current 1 ... 150 mA
- Output voltage 0 ... 1 V DC
- Type of output 2 semiconductor outputs, p-switching, short circuit-proof
- Switching load 24V DC, class 2 (Alternatively see operating instructions)
- Risk time according to EN 60947-5-3 max.260 ms
- Safety class III
- Rated insulation voltage Ui 50 V
- Degree of contamination (external, according to EN 60947-1) 3
- Solenoid duty cycle 100 %
- EMC protection requirements In acc. with EN IEC 60947-5-3
- Connection rating 6 W
- Fusing 0,5 ... 8 A
- Rated impulse withstand voltage Uimp 0,5 kV
- Utilization category acc. to EN 60947-5-2 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
- Solenoid operating voltage DC 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
- Current consumption 40 mA
- Operating voltage DC 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
- Test pulses max.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
- Test-pulse interval min.140 ms
- Extension of risk time according to EN 60947-5-3 per device max.5 ms
- Overtravel 5 mm
- Extraction force 20 N
- Actuating force 10 N
- Retention force 20 N
- Locking force FZh 3000 N (Fzh = Fmax/1.3 Depending on the actuator used)
- Locking force Fmax 3900 N
- Connection 2 plug connectors M12, 5 and 8-pin
- Approach speed max.20 m/min
- Guard locking principle Closed-circuit current principle
- Switching frequency max.0,5 Hz
- Mechanical life 1 x 10⁶
- Ready delay 8 s
- Installation orientation Any
- Degree of protection IP67/IP69/IP69K (Screwed tight plug connector/mating component)
- Ambient temperature -20 ... +55 °C
- Housing material Fiber glass reinforced thermoplastic
- Weight 0,42 kg
- Shock and vibration resistance In acc. with EN 60947-5-3
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
$772.00
Select Qty:
$772.00
$772.00 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Relevant products
What can I help you find today?