Product description
120990 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 1 pushbutton
Product Details
- Weight 2.18698304 lb
- Series Spare parts
- Product Class Accessories
- Mission time 20 y
- PFHD 3.7 x 10⁻⁹
- Additional feature Incl. cover set ID. No. 120344
- Category 4
- Performance Level PL e
- Product version number V4.0.0
- Switching element 1NO
- Version Illuminated push buttons
- Power supply LED 24 V DC
- Switching current 1 ... 10 mA
- Assignment diagram L1
- Output voltage UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
- Switching voltage UA V
- Breaking capacity max.0,25 W
- Output current 1 ... 200 mA
- Operating voltage DC 24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
- Current consumption max.80 mA ((no load on outputs))
- Test pulses max.1 ms
- Type of output Semiconductor outputs, p-switching, short circuit-proof
- Test-pulse interval min.100 ms
- Transponder coding Unicode
- Connection cross-section 0,25 ... 0,75 mm²
- Rated insulation voltage Ui 30 V
- Discrepancy time max.10 ms
- Utilization category acc. to EN 60947-5-2 24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
- Safety class III
- Degree of contamination (external, according to EN 60947-1) 3
- Rated impulse withstand voltage Uimp 1,5 kV
- Risk time according to EN 60947-5-3 max.350 ms
- Locking force FZh 2000 N
- Installation orientation Door hinge DIN right
- Degree of protection IP65
- Guard locking principle Closed-circuit current principle
- Switching frequency 0,25 Hz
- Housing material Reinforced plastic; die-cast zinc nickel-plated, stainless steel
- Ambient temperature -20 ... 55 °C
- Mechanical life 0,1 x 10⁶
- Connection Cable entries M20x1.5
- Weight 0,75 kg
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 120990 on MQ Automation is $1,016.07. Order now.
About the product
Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);1 pushbuttons (illuminated);With lens set, 6 pcs.;With cable entry;Unicode
Manufacturer warranty
120990 Euchner
$1,016.07
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$1,016.07
$1,016.07 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 120990 with other products
Weight
Series
Product Class
Mission time
PFHD
Additional feature
Category
Performance Level
Product version number
Switching element
Version
Power supply LED
Switching current
Assignment diagram
Output voltage
Switching voltage
Breaking capacity
Output current
Operating voltage DC
Current consumption
Test pulses
Type of output
Test-pulse interval
Transponder coding
Connection cross-section
Rated insulation voltage Ui
Discrepancy time
Utilization category acc. to EN 60947-5-2
Safety class
Degree of contamination (external, according to EN 60947-1)
Rated impulse withstand voltage Uimp
Risk time according to EN 60947-5-3
Locking force FZh
Installation orientation
Degree of protection
Guard locking principle
Switching frequency
Housing material
Ambient temperature
Mechanical life
Connection
Weight
Mission time
PFHD
Category
Performance Level
For the approval acc. to UL the following applies
Additional feature
Repeat accuracy R
Discrepancy time
Output voltage
Turn-on time
Off-state current Ir
Switching current
Type of output
Switching load
Risk time according to EN 60947-5-3
Safety class
Degree of contamination (external, according to EN 60947-1)
Solenoid duty cycle
EMC protection requirements
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Connection rating
Fusing
Solenoid operating voltage DC
Operating voltage DC
Utilization category acc. to EN 60947-5-2
Test pulses
Test-pulse interval
Actuating force
Extension of risk time according to EN 60947-5-3 per device
Current consumption
Extraction force
Overtravel
Locking force Fmax
Approach speed
Retention force
Connection
Locking force FZh
Guard locking principle
Mechanical life
Ambient temperature
Degree of protection
Switching frequency
Weight
Ready delay
Installation orientation
Shock and vibration resistance
Housing material
B10D
Mission time
PFHD
Performance Level
Category
For the approval acc. to UL the following applies
Version
Operating current
Switching element
Repeat accuracy R
Detent mechanism
Discrepancy time
Off-state current Ir
Operating voltage
Switching current
Type of output
Safety class
Turn-on time
Switching load
EMC protection requirements
Output voltage
Degree of contamination (external, according to EN 60947-1)
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
Connection rating
Utilization category acc. to EN 60947-5-2
Fusing
Current consumption
Operating voltage DC
Overtravel
Test-pulse interval
Ambient temperature
Extraction force
Test pulses
Actuating force
Installation orientation
Mechanical life
Shock and vibration resistance
Housing material
Approach speed
Degree of protection
Switching frequency
Weight
Ready delay
Connection
Selected product

120990
Euchner
120990 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 1 pushbutton
Weight2.18698304 lb
SeriesSpare parts
Product ClassAccessories
Mission time20 y
PFHD3.7 x 10⁻⁹
Additional featureIncl. cover set ID. No. 120344
Category4
Performance LevelPL e
Product version numberV4.0.0
Switching element1NO
VersionIlluminated push buttons
Power supply LED24 V DC
Switching current1 ... 10 mA
Assignment diagramL1
Output voltageUB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
Switching voltageU<sub>A</sub> V
Breaking capacitymax.0,25 W
Output current1 ... 200 mA
Operating voltage DC24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
Current consumptionmax.80 mA ((no load on outputs))
Test pulsesmax.1 ms
Type of outputSemiconductor outputs, p-switching, short circuit-proof
Test-pulse intervalmin.100 ms
Transponder codingUnicode
Connection cross-section0,25 ... 0,75 mm²
Rated insulation voltage Ui30 V
Discrepancy timemax.10 ms
Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Rated impulse withstand voltage Uimp1,5 kV
Risk time according to EN 60947-5-3max.350 ms
Locking force FZh2000 N
Installation orientationDoor hinge DIN right
Degree of protectionIP65
Guard locking principleClosed-circuit current principle
Switching frequency0,25 Hz
Housing materialReinforced plastic; die-cast zinc nickel-plated, stainless steel
Ambient temperature-20 ... 55 °C
Mechanical life0,1 x 10⁶
ConnectionCable entries M20x1.5
Weight0,75 kg
Mission time-
PFHD-
Category-
Performance Level-
For the approval acc. to UL the following applies-
Additional feature-
Repeat accuracy R-
Discrepancy time-
Output voltage-
Turn-on time-
Off-state current Ir-
Switching current-
Type of output-
Switching load-
Risk time according to EN 60947-5-3-
Safety class-
Degree of contamination (external, according to EN 60947-1)-
Solenoid duty cycle-
EMC protection requirements-
Rated impulse withstand voltage Uimp-
Rated insulation voltage Ui-
Connection rating-
Fusing-
Solenoid operating voltage DC-
Operating voltage DC-
Utilization category acc. to EN 60947-5-2-
Test pulses-
Test-pulse interval-
Actuating force-
Extension of risk time according to EN 60947-5-3 per device-
Current consumption-
Extraction force-
Overtravel-
Locking force Fmax-
Approach speed-
Retention force-
Connection-
Locking force FZh-
Guard locking principle-
Mechanical life-
Ambient temperature-
Degree of protection-
Switching frequency-
Weight-
Ready delay-
Installation orientation-
Shock and vibration resistance-
Housing material-
B10D-
Mission time-
PFHD-
Performance Level-
Category-
For the approval acc. to UL the following applies-
Version-
Operating current-
Switching element-
Repeat accuracy R-
Detent mechanism-
Discrepancy time-
Off-state current Ir-
Operating voltage-
Switching current-
Type of output-
Safety class-
Turn-on time-
Switching load-
EMC protection requirements-
Output voltage-
Degree of contamination (external, according to EN 60947-1)-
Rated insulation voltage Ui-
Rated impulse withstand voltage Uimp-
Connection rating-
Utilization category acc. to EN 60947-5-2-
Fusing-
Current consumption-
Operating voltage DC-
Overtravel-
Test-pulse interval-
Ambient temperature-
Extraction force-
Test pulses-
Actuating force-
Installation orientation-
Mechanical life-
Shock and vibration resistance-
Housing material-
Approach speed-
Degree of protection-
Switching frequency-
Weight-
Ready delay-
Connection-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 120990?
The price of 120990 on MQ Automation is $1,016.07. Order now.
Out if stock but available for backorder.
120990 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 1 pushbutton
Similar products from: Safety Accessories
What can I help you find today?