119757 Euchner Safety Accessories

119757 on MQ Automation
Euchner

Part#:119757

Alt. Part#:MGB-L1-ARA-AD3A1-S1-R-119757

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

119757 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 3 pushbutton, RC18

Product Details

  • Weight
    4.40924 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Category
    4
  • Switching element
    1NO
  • Product version number
    V4.0.0
  • Version
    Illuminated push buttons
  • Power supply LED
    24 V DC
  • Assignment diagram
    L1
  • Color
    Blue
  • Breaking capacity
    max.0,25 W
  • Output voltage
    0 ... 1 V DC
  • Output current
    1 ... 200 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test pulses
    max.1 ms
  • Switching current
    1 ... 10 mA
  • Switching voltage
    UA V
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Current consumption
    max.80 mA ((no load on outputs))
  • Test-pulse interval
    min.100 ms
  • Discrepancy time
    max.10 ms
  • Transponder coding
    Unicode
  • Locking force FZh
    2000 N
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Safety class
    III
  • Rated insulation voltage Ui
    30 V
  • Ambient temperature
    -20 ... 55 °C
  • Installation orientation
    Door hinge DIN right
  • Connection
    Plug connector RC18 (X6)
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Degree of protection
    IP65
  • Weight
    0,75 kg
  • Guard locking principle
    Closed-circuit current principle

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 119757 on MQ Automation is $1,484.72. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);1 pushbutton (illuminated, bu);1 pushbutton (illuminated, with button labeling “Unlocked,” wh);1 pushbutton (illuminated, with button labeling “Locked,” wh);With plug connector RC18;Unicode


Manufacturer warranty

119757 Euchner

$1,484.72

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,484.72

$1,484.72 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 119757 with other products

Weight

Series

Product Class

Mission time

PFHD

Performance Level

Category

Switching element

Product version number

Version

Power supply LED

Assignment diagram

Color

Breaking capacity

Output voltage

Output current

Type of output

Test pulses

Switching current

Switching voltage

Operating voltage DC

Current consumption

Test-pulse interval

Discrepancy time

Transponder coding

Locking force FZh

Rated impulse withstand voltage Uimp

Utilization category acc. to EN 60947-5-2

Risk time according to EN 60947-5-3

Degree of contamination (external, according to EN 60947-1)

Safety class

Rated insulation voltage Ui

Ambient temperature

Installation orientation

Connection

Mechanical life

Switching frequency

Housing material

Degree of protection

Weight

Guard locking principle

B10D

Mission time

PFHD

Performance Level

Category

For the approval acc. to UL the following applies

Version

Operating current

Switching element

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Safety class

Turn-on time

Switching load

EMC protection requirements

Output voltage

Degree of contamination (external, according to EN 60947-1)

Rated insulation voltage Ui

Rated impulse withstand voltage Uimp

Connection rating

Utilization category acc. to EN 60947-5-2

Fusing

Current consumption

Operating voltage DC

Overtravel

Test-pulse interval

Ambient temperature

Extraction force

Test pulses

Actuating force

Installation orientation

Mechanical life

Shock and vibration resistance

Housing material

Approach speed

Degree of protection

Switching frequency

Weight

Ready delay

Connection

Mission time

PFHD

Category

Performance Level

For the approval acc. to UL the following applies

Additional feature

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Switching current

Type of output

Switching load

Risk time according to EN 60947-5-3

Safety class

Degree of contamination (external, according to EN 60947-1)

Solenoid duty cycle

EMC protection requirements

Rated impulse withstand voltage Uimp

Rated insulation voltage Ui

Connection rating

Fusing

Solenoid operating voltage DC

Operating voltage DC

Utilization category acc. to EN 60947-5-2

Test pulses

Test-pulse interval

Actuating force

Extension of risk time according to EN 60947-5-3 per device

Current consumption

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Connection

Locking force FZh

Guard locking principle

Mechanical life

Ambient temperature

Degree of protection

Switching frequency

Weight

Ready delay

Installation orientation

Shock and vibration resistance

Housing material

Selected product

119757
0 in stock
119757
Euchner

119757 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 3 pushbutton, RC...

Weight4.40924 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

PFHD3.7 x 10⁻⁹

Performance LevelPL e

Category4

Switching element1NO

Product version numberV4.0.0

VersionIlluminated push buttons

Power supply LED24 V DC

Assignment diagramL1

ColorBlue

Breaking capacitymax.0,25 W

Output voltage0 ... 1 V DC

Output current1 ... 200 mA

Type of outputSemiconductor outputs, p-switching, short circuit-proof

Test pulsesmax.1 ms

Switching current1 ... 10 mA

Switching voltageU<sub>A</sub> V

Operating voltage DC24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))

Current consumptionmax.80 mA ((no load on outputs))

Test-pulse intervalmin.100 ms

Discrepancy timemax.10 ms

Transponder codingUnicode

Locking force FZh2000 N

Rated impulse withstand voltage Uimp1,5 kV

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)

Risk time according to EN 60947-5-3max.350 ms

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

Rated insulation voltage Ui30 V

Ambient temperature-20 ... 55 °C

Installation orientationDoor hinge DIN right

ConnectionPlug connector RC18 (X6)

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

Housing materialReinforced plastic; die-cast zinc nickel-plated, stainless steel

Degree of protectionIP65

Weight0,75 kg

Guard locking principleClosed-circuit current principle

B10D-

Mission time-

PFHD-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Fusing-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Ambient temperature-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Mechanical life-

Shock and vibration resistance-

Housing material-

Approach speed-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Connection-

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Locking force FZh-

Guard locking principle-

Mechanical life-

Ambient temperature-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Installation orientation-

Shock and vibration resistance-

Housing material-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time-

PFHD-

Performance Level-

Category-

Switching element-

Product version number-

Version-

Power supply LED-

Assignment diagram-

Color-

Breaking capacity-

Output voltage-

Output current-

Type of output-

Test pulses-

Switching current-

Switching voltage-

Operating voltage DC-

Current consumption-

Test-pulse interval-

Discrepancy time-

Transponder coding-

Locking force FZh-

Rated impulse withstand voltage Uimp-

Utilization category acc. to EN 60947-5-2-

Risk time according to EN 60947-5-3-

Degree of contamination (external, according to EN 60947-1)-

Safety class-

Rated insulation voltage Ui-

Ambient temperature-

Installation orientation-

Connection-

Mechanical life-

Switching frequency-

Housing material-

Degree of protection-

Weight-

Guard locking principle-

B10D0,13 x 10⁶

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN IEC 60947-5-3

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-switching, short circuit-proof

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternatively see operating instructions)

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Output voltage0 ... 1 V DC

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Fusing0,25 ... 8 A

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Overtravel5 mm

Test-pulse intervalmin.100 ms

Ambient temperature-20 ... +55 °C

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Actuating force10 N

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialFiber glass reinforced thermoplastic

Approach speedmax.20 m/min

Degree of protectionIP65 (Screwed tight plug connector/mating component)

Switching frequencymax.0,5 Hz

Weight1,25 kg

Ready delaymax.1 s

Connection2 plug connectors M12, 5-pin

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Locking force FZh-

Guard locking principle-

Mechanical life-

Ambient temperature-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Installation orientation-

Shock and vibration resistance-

Housing material-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time-

PFHD-

Performance Level-

Category-

Switching element-

Product version number-

Version-

Power supply LED-

Assignment diagram-

Color-

Breaking capacity-

Output voltage-

Output current-

Type of output-

Test pulses-

Switching current-

Switching voltage-

Operating voltage DC-

Current consumption-

Test-pulse interval-

Discrepancy time-

Transponder coding-

Locking force FZh-

Rated impulse withstand voltage Uimp-

Utilization category acc. to EN 60947-5-2-

Risk time according to EN 60947-5-3-

Degree of contamination (external, according to EN 60947-1)-

Safety class-

Rated insulation voltage Ui-

Ambient temperature-

Installation orientation-

Connection-

Mechanical life-

Switching frequency-

Housing material-

Degree of protection-

Weight-

Guard locking principle-

B10D-

Mission time-

PFHD-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Fusing-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Ambient temperature-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Mechanical life-

Shock and vibration resistance-

Housing material-

Approach speed-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Connection-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

Additional featureEscape release actuated by pushing

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN IEC 60947-5-3

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-proof

Switching load24V DC, class 2 (Alternatively see operating instructions)

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Operating voltage DC24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Test pulsesmax.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumption40 mA

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Connection2 plug connectors M12, 5 and 8-pin

Locking force FZh3000 N (Fzh = Fmax/1.3 Depending on the actuator used)

Guard locking principleClosed-circuit current principle

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed tight plug connector/mating component)

Switching frequencymax.0,5 Hz

Weight0,42 kg

Ready delay8 s

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialDie-cast zinc

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 119757?
The price of 119757 on MQ Automation is $1,484.72. Order now.

Out if stock but available for backorder.

119757 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 3 pushbutton, RC18

What can I help you find today?

Recommended parts