110793 Euchner Safety Accessories


Part#:110793
Alt. Part#:MGB-L1-ARA-AA2A1-S1-L-110793
Manufacturer:Euchner
Category:Safety Accessories
Product Lifecycle:Active
Product description
110793 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18
Product Details
- Weight 2.34351106 lb
- Series Spare parts
- Product Class Accessories
- Mission time 20 y
- B10D 0,13 x 10⁶
- PFHD 3.7 x 10⁻⁹
- Performance Level PL e
- Switching element 2 pos. driven NC
- Product version number V4.0.0
- Version Emergency stop
- Category 4
- Power supply LED 24 V DC
- Assignment diagram L1
- Output voltage UA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths)
- Switching current 1 ... 10 mA
- Type of output Semiconductor outputs, p-switching, short circuit-proof
- Switching voltage UA V
- Test-pulse interval min.100 ms
- Test pulses max.1 ms
- Breaking capacity max.0,25 W
- Output current max.50 mA
- Operating voltage DC 24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
- Discrepancy time max.10 ms
- Risk time according to EN 60947-5-3 max.350 ms
- Transponder coding Unicode
- Safety class III
- Current consumption max.80 mA ((no load on outputs))
- Degree of contamination (external, according to EN 60947-1) 3
- Rated impulse withstand voltage Uimp 1,5 kV
- Utilization category acc. to EN 60947-5-2 24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
- Switching frequency 0,25 Hz
- Rated insulation voltage Ui 30 V
- Locking force FZh 2000 N
- Installation orientation Door hinge DIN left
- Guard locking principle Closed-circuit current principle
- Connection Plug connector RC18 (X6)
- Mechanical life 0,1 x 10⁶
- Degree of protection IP65
- Weight 0,75 kg
- Ambient temperature -20 ... 55 °C
- Housing material Reinforced plastic; die-cast zinc nickel-plated, stainless steel
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 110793 on MQ Automation is $1,484.72. Order now.
About the product
Guard locking and guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);Emergency stop according to ISO 13850;2 pushbuttons (illuminated, ye, wh);incl. adhesive labels;With plug connector RC18;Unicode
Manufacturer warranty
110793 Euchner
$1,484.72
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$1,484.72
$1,484.72 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 110793 with other products
Weight
Series
Product Class
Mission time
B10D
PFHD
Performance Level
Switching element
Product version number
Version
Category
Power supply LED
Assignment diagram
Output voltage
Switching current
Type of output
Switching voltage
Test-pulse interval
Test pulses
Breaking capacity
Output current
Operating voltage DC
Discrepancy time
Risk time according to EN 60947-5-3
Transponder coding
Safety class
Current consumption
Degree of contamination (external, according to EN 60947-1)
Rated impulse withstand voltage Uimp
Utilization category acc. to EN 60947-5-2
Switching frequency
Rated insulation voltage Ui
Locking force FZh
Installation orientation
Guard locking principle
Connection
Mechanical life
Degree of protection
Weight
Ambient temperature
Housing material
B10D
Mission time
PFHD
Performance Level
Category
For the approval acc. to UL the following applies
Version
Operating current
Switching element
Repeat accuracy R
Detent mechanism
Discrepancy time
Off-state current Ir
Operating voltage
Switching current
Type of output
Safety class
Turn-on time
Switching load
EMC protection requirements
Output voltage
Degree of contamination (external, according to EN 60947-1)
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
Connection rating
Utilization category acc. to EN 60947-5-2
Fusing
Current consumption
Operating voltage DC
Overtravel
Test-pulse interval
Ambient temperature
Extraction force
Test pulses
Actuating force
Installation orientation
Mechanical life
Shock and vibration resistance
Housing material
Approach speed
Degree of protection
Switching frequency
Weight
Ready delay
Connection
Mission time
PFHD
Category
Performance Level
For the approval acc. to UL the following applies
Additional feature
Repeat accuracy R
Discrepancy time
Output voltage
Turn-on time
Off-state current Ir
Switching current
Type of output
Switching load
Risk time according to EN 60947-5-3
Safety class
Degree of contamination (external, according to EN 60947-1)
Solenoid duty cycle
EMC protection requirements
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Connection rating
Fusing
Solenoid operating voltage DC
Operating voltage DC
Utilization category acc. to EN 60947-5-2
Test pulses
Test-pulse interval
Actuating force
Extension of risk time according to EN 60947-5-3 per device
Current consumption
Extraction force
Overtravel
Locking force Fmax
Approach speed
Retention force
Connection
Locking force FZh
Guard locking principle
Mechanical life
Ambient temperature
Degree of protection
Switching frequency
Weight
Ready delay
Installation orientation
Shock and vibration resistance
Housing material
Selected product

110793
Euchner
110793 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, em...
Weight2.34351106 lb
SeriesSpare parts
Product ClassAccessories
Mission time20 y
B10D0,13 x 10⁶
PFHD3.7 x 10⁻⁹
Performance LevelPL e
Switching element2 pos. driven NC
Product version numberV4.0.0
VersionEmergency stop
Category4
Power supply LED24 V DC
Assignment diagramL1
Output voltageUA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths)
Switching current1 ... 10 mA
Type of outputSemiconductor outputs, p-switching, short circuit-proof
Switching voltageU<sub>A</sub> V
Test-pulse intervalmin.100 ms
Test pulsesmax.1 ms
Breaking capacitymax.0,25 W
Output currentmax.50 mA
Operating voltage DC24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
Discrepancy timemax.10 ms
Risk time according to EN 60947-5-3max.350 ms
Transponder codingUnicode
Safety classIII
Current consumptionmax.80 mA ((no load on outputs))
Degree of contamination (external, according to EN 60947-1)3
Rated impulse withstand voltage Uimp1,5 kV
Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Switching frequency0,25 Hz
Rated insulation voltage Ui30 V
Locking force FZh2000 N
Installation orientationDoor hinge DIN left
Guard locking principleClosed-circuit current principle
ConnectionPlug connector RC18 (X6)
Mechanical life0,1 x 10⁶
Degree of protectionIP65
Weight0,75 kg
Ambient temperature-20 ... 55 °C
Housing materialReinforced plastic; die-cast zinc nickel-plated, stainless steel
B10D-
Mission time-
PFHD-
Performance Level-
Category-
For the approval acc. to UL the following applies-
Version-
Operating current-
Switching element-
Repeat accuracy R-
Detent mechanism-
Discrepancy time-
Off-state current Ir-
Operating voltage-
Switching current-
Type of output-
Safety class-
Turn-on time-
Switching load-
EMC protection requirements-
Output voltage-
Degree of contamination (external, according to EN 60947-1)-
Rated insulation voltage Ui-
Rated impulse withstand voltage Uimp-
Connection rating-
Utilization category acc. to EN 60947-5-2-
Fusing-
Current consumption-
Operating voltage DC-
Overtravel-
Test-pulse interval-
Ambient temperature-
Extraction force-
Test pulses-
Actuating force-
Installation orientation-
Mechanical life-
Shock and vibration resistance-
Housing material-
Approach speed-
Degree of protection-
Switching frequency-
Weight-
Ready delay-
Connection-
Mission time-
PFHD-
Category-
Performance Level-
For the approval acc. to UL the following applies-
Additional feature-
Repeat accuracy R-
Discrepancy time-
Output voltage-
Turn-on time-
Off-state current Ir-
Switching current-
Type of output-
Switching load-
Risk time according to EN 60947-5-3-
Safety class-
Degree of contamination (external, according to EN 60947-1)-
Solenoid duty cycle-
EMC protection requirements-
Rated impulse withstand voltage Uimp-
Rated insulation voltage Ui-
Connection rating-
Fusing-
Solenoid operating voltage DC-
Operating voltage DC-
Utilization category acc. to EN 60947-5-2-
Test pulses-
Test-pulse interval-
Actuating force-
Extension of risk time according to EN 60947-5-3 per device-
Current consumption-
Extraction force-
Overtravel-
Locking force Fmax-
Approach speed-
Retention force-
Connection-
Locking force FZh-
Guard locking principle-
Mechanical life-
Ambient temperature-
Degree of protection-
Switching frequency-
Weight-
Ready delay-
Installation orientation-
Shock and vibration resistance-
Housing material-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 110793?
The price of 110793 on MQ Automation is $1,484.72. Order now.
Out if stock but available for backorder.
110793 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18
Similar products from: Safety Accessories
What can I help you find today?