110708 Euchner Safety Accessories

110708 on MQ Automation
Euchner

Part#:110708

Alt. Part#:MGB-L2-ARA-AA2A1-S1-R-110708

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

110708 Euchner - Locking module MGB-L2-ARA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18

Product Details

  • Weight
    2.32366948 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Performance Level
    PL e
  • B10D
    0,13 x 10⁶
  • Category
    4
  • PFHD
    3.7 x 10⁻⁹
  • Product version number
    V4.0.0
  • Version
    Emergency stop
  • Mission time
    20 y
  • Assignment diagram
    L1
  • Switching element
    2 pos. driven NC
  • Power supply LED
    24 V DC
  • Breaking capacity
    max.0,25 W
  • Output current
    1 ... 200 mA
  • Output voltage
    0 ... 1 V DC
  • Switching current
    1 ... 10 mA
  • Switching voltage
    UA V
  • Test-pulse interval
    min.100 ms
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test pulses
    max.1 ms
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Current consumption
    max.80 mA ((no load on outputs))
  • Rated insulation voltage Ui
    30 V
  • Transponder coding
    Unicode
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Safety class
    III
  • Discrepancy time
    max.10 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Locking force FZh
    2000 N
  • Guard locking principle
    Open-circuit current principle
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Switching frequency
    0,25 Hz
  • Mechanical life
    0,1 x 10⁶
  • Degree of protection
    IP65
  • Weight
    0,75 kg
  • Connection
    Plug connector RC18 (X6)
  • Installation orientation
    Door hinge DIN right
  • Ambient temperature
    -20 ... 55 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 110708 on MQ Automation is $1,452.48. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);Emergency stop according to ISO 13850;2 pushbuttons (illuminated, ye, wh);incl. adhesive labels;Plug connector RC18;Unicode


Manufacturer warranty

110708 Euchner

$1,452.48

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,452.48

$1,452.48 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 110708 with other products

Weight

Series

Product Class

Performance Level

B10D

Category

PFHD

Product version number

Version

Mission time

Assignment diagram

Switching element

Power supply LED

Breaking capacity

Output current

Output voltage

Switching current

Switching voltage

Test-pulse interval

Type of output

Test pulses

Risk time according to EN 60947-5-3

Current consumption

Rated insulation voltage Ui

Transponder coding

Operating voltage DC

Safety class

Discrepancy time

Degree of contamination (external, according to EN 60947-1)

Rated impulse withstand voltage Uimp

Utilization category acc. to EN 60947-5-2

Locking force FZh

Guard locking principle

Housing material

Switching frequency

Mechanical life

Degree of protection

Weight

Connection

Installation orientation

Ambient temperature

B10D

Mission time

PFHD

Performance Level

Category

For the approval acc. to UL the following applies

Version

Operating current

Switching element

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Safety class

Turn-on time

Switching load

EMC protection requirements

Output voltage

Degree of contamination (external, according to EN 60947-1)

Rated insulation voltage Ui

Rated impulse withstand voltage Uimp

Connection rating

Utilization category acc. to EN 60947-5-2

Fusing

Current consumption

Operating voltage DC

Overtravel

Test-pulse interval

Ambient temperature

Extraction force

Test pulses

Actuating force

Installation orientation

Mechanical life

Shock and vibration resistance

Housing material

Approach speed

Degree of protection

Switching frequency

Weight

Ready delay

Connection

Mission time

PFHD

Category

Performance Level

For the approval acc. to UL the following applies

Additional feature

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Switching current

Type of output

Switching load

Risk time according to EN 60947-5-3

Safety class

Degree of contamination (external, according to EN 60947-1)

Solenoid duty cycle

EMC protection requirements

Rated impulse withstand voltage Uimp

Rated insulation voltage Ui

Connection rating

Fusing

Solenoid operating voltage DC

Operating voltage DC

Utilization category acc. to EN 60947-5-2

Test pulses

Test-pulse interval

Actuating force

Extension of risk time according to EN 60947-5-3 per device

Current consumption

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Connection

Locking force FZh

Guard locking principle

Mechanical life

Ambient temperature

Degree of protection

Switching frequency

Weight

Ready delay

Installation orientation

Shock and vibration resistance

Housing material

Selected product

110708
0 in stock
110708
Euchner

110708 Euchner - Locking module MGB-L2-ARA... (guard locking by solenoid force) with 2 pushbuttons, ...

Weight2.32366948 lb

SeriesSpare parts

Product ClassAccessories

Performance LevelPL e

B10D0,13 x 10⁶

Category4

PFHD3.7 x 10⁻⁹

Product version numberV4.0.0

VersionEmergency stop

Mission time20 y

Assignment diagramL1

Switching element2 pos. driven NC

Power supply LED24 V DC

Breaking capacitymax.0,25 W

Output current1 ... 200 mA

Output voltage0 ... 1 V DC

Switching current1 ... 10 mA

Switching voltageU<sub>A</sub> V

Test-pulse intervalmin.100 ms

Type of outputSemiconductor outputs, p-switching, short circuit-proof

Test pulsesmax.1 ms

Risk time according to EN 60947-5-3max.350 ms

Current consumptionmax.80 mA ((no load on outputs))

Rated insulation voltage Ui30 V

Transponder codingUnicode

Operating voltage DC24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))

Safety classIII

Discrepancy timemax.10 ms

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)

Locking force FZh2000 N

Guard locking principleOpen-circuit current principle

Housing materialReinforced plastic; die-cast zinc nickel-plated, stainless steel

Switching frequency0,25 Hz

Mechanical life0,1 x 10⁶

Degree of protectionIP65

Weight0,75 kg

ConnectionPlug connector RC18 (X6)

Installation orientationDoor hinge DIN right

Ambient temperature-20 ... 55 °C

B10D-

Mission time-

PFHD-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Fusing-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Ambient temperature-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Mechanical life-

Shock and vibration resistance-

Housing material-

Approach speed-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Connection-

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Locking force FZh-

Guard locking principle-

Mechanical life-

Ambient temperature-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Installation orientation-

Shock and vibration resistance-

Housing material-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Performance Level-

B10D-

Category-

PFHD-

Product version number-

Version-

Mission time-

Assignment diagram-

Switching element-

Power supply LED-

Breaking capacity-

Output current-

Output voltage-

Switching current-

Switching voltage-

Test-pulse interval-

Type of output-

Test pulses-

Risk time according to EN 60947-5-3-

Current consumption-

Rated insulation voltage Ui-

Transponder coding-

Operating voltage DC-

Safety class-

Discrepancy time-

Degree of contamination (external, according to EN 60947-1)-

Rated impulse withstand voltage Uimp-

Utilization category acc. to EN 60947-5-2-

Locking force FZh-

Guard locking principle-

Housing material-

Switching frequency-

Mechanical life-

Degree of protection-

Weight-

Connection-

Installation orientation-

Ambient temperature-

B10D0,13 x 10⁶

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN IEC 60947-5-3

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-switching, short circuit-proof

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternatively see operating instructions)

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Output voltage0 ... 1 V DC

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Fusing0,25 ... 8 A

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Overtravel5 mm

Test-pulse intervalmin.100 ms

Ambient temperature-20 ... +55 °C

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Actuating force10 N

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialFiber glass reinforced thermoplastic

Approach speedmax.20 m/min

Degree of protectionIP65 (Screwed tight plug connector/mating component)

Switching frequencymax.0,5 Hz

Weight1,25 kg

Ready delaymax.1 s

Connection2 plug connectors M12, 5-pin

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

Solenoid duty cycle-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Locking force FZh-

Guard locking principle-

Mechanical life-

Ambient temperature-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Installation orientation-

Shock and vibration resistance-

Housing material-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Performance Level-

B10D-

Category-

PFHD-

Product version number-

Version-

Mission time-

Assignment diagram-

Switching element-

Power supply LED-

Breaking capacity-

Output current-

Output voltage-

Switching current-

Switching voltage-

Test-pulse interval-

Type of output-

Test pulses-

Risk time according to EN 60947-5-3-

Current consumption-

Rated insulation voltage Ui-

Transponder coding-

Operating voltage DC-

Safety class-

Discrepancy time-

Degree of contamination (external, according to EN 60947-1)-

Rated impulse withstand voltage Uimp-

Utilization category acc. to EN 60947-5-2-

Locking force FZh-

Guard locking principle-

Housing material-

Switching frequency-

Mechanical life-

Degree of protection-

Weight-

Connection-

Installation orientation-

Ambient temperature-

B10D-

Mission time-

PFHD-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Fusing-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Ambient temperature-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Mechanical life-

Shock and vibration resistance-

Housing material-

Approach speed-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Connection-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

Additional featureEscape release actuated by pushing

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN IEC 60947-5-3

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-proof

Switching load24V DC, class 2 (Alternatively see operating instructions)

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Operating voltage DC24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Test pulsesmax.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumption40 mA

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Connection2 plug connectors M12, 5 and 8-pin

Locking force FZh3000 N (Fzh = Fmax/1.3 Depending on the actuator used)

Guard locking principleClosed-circuit current principle

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed tight plug connector/mating component)

Switching frequencymax.0,5 Hz

Weight0,42 kg

Ready delay8 s

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialDie-cast zinc

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 110708?
The price of 110708 on MQ Automation is $1,452.48. Order now.

Out if stock but available for backorder.

110708 Euchner - Locking module MGB-L2-ARA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18

What can I help you find today?

Recommended parts