110260 Euchner - MULTIFUNCTIONAL GATE BOX COMPLETE

Product Details

  • Weight
    3.234735 lb
  • B10D
    0,13 x 10⁶
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Category
    4
  • Product version number
    V4.0.0
  • Performance Level
    PL e
  • Version
    Illuminated push buttons
  • Color
    white
  • Switching element
    1NO
  • Assignment diagram
    C2
  • Power supply LED
    24 V DC
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Switching voltage
    UA V
  • Connection
    Plug connector RC26 (X6)
  • Mechanical life
    0,1 x 10⁶
  • Breaking capacity
    max.0,25 W
  • Output current
    1 ... 200 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Installation orientation
    Door hinge DIN left
  • Test-pulse interval
    min.100 ms
  • Switching current
    1 ... 10 mA
  • Ambient temperature
    -20 ... 55 °C
  • Test pulses
    max.1 ms
  • Current consumption
    max.80 mA ((no load on outputs))
  • Switching frequency
    0,25 Hz
  • Transponder coding
    Unicode
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Weight
    1,4 kg
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Discrepancy time
    max.10 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Safety class
    III
  • Degree of protection
    IP65
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Rated insulation voltage Ui
    30 V
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 110260 on MQ Automation is $2,063.29. Order now.


Manufacturer warranty

110260 Euchner

$2,063.29

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$2,063.29

$2,063.29 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 110260 with other products

Weight

B10D

Mission time

PFHD

Category

Product version number

Performance Level

Version

Color

Switching element

Assignment diagram

Power supply LED

Output voltage

Switching voltage

Connection

Mechanical life

Breaking capacity

Output current

Type of output

Installation orientation

Test-pulse interval

Switching current

Ambient temperature

Test pulses

Current consumption

Switching frequency

Transponder coding

Operating voltage DC

Housing material

Weight

Risk time according to EN 60947-5-3

Discrepancy time

Degree of contamination (external, according to EN 60947-1)

Safety class

Degree of protection

Rated impulse withstand voltage Uimp

Rated insulation voltage Ui

Utilization category acc. to EN 60947-5-2

Series

Product Class

B10D

Mission time

PFHD

Performance Level

Category

For the approval acc. to UL the following applies

Version

Operating current

Switching element

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Safety class

Turn-on time

Switching load

EMC protection requirements

Output voltage

Degree of contamination (external, according to EN 60947-1)

Rated insulation voltage Ui

Rated impulse withstand voltage Uimp

Connection rating

Utilization category acc. to EN 60947-5-2

Fusing

Current consumption

Operating voltage DC

Overtravel

Test-pulse interval

Ambient temperature

Extraction force

Test pulses

Actuating force

Installation orientation

Mechanical life

Shock and vibration resistance

Housing material

Approach speed

Degree of protection

Switching frequency

Weight

Ready delay

Connection

Switching hysteresis

Assured operating distance Sao

Assured release distance Sar

PFHD

Operating distance

Mission time

Performance Level

Category

For the approval acc. to UL the following applies

Repeat accuracy R

Discrepancy time

Off-state current Ir

Utilization category acc. to EN 60947-5-2

Rated conditional short-circuit current

Test pulses

Test-pulse interval

Output voltage

Switching current

Turn-on time

Risk time according to EN 60947-5-3

Type of output

Fusing

Rated impulse withstand voltage Uimp

Rated insulation voltage Ui

Degree of contamination (external, according to EN 60947-1)

Safety class

EMC protection requirements

Extension of risk time according to EN 60947-5-3 per device

Tightening torque

Current consumption

Installation orientation

Mounting distance

Operating voltage DC

Connection

Switching frequency

Ready delay

Cable ambient temperature (dynamic)

Degree of protection

Mounting method

Static bending radius

Weight

Shock and vibration resistance

Cable ambient temperature (static)

Housing material

Dynamic bending radius

Selected product

110260
0 in stock
110260
Euchner

110260 Euchner - MULTIFUNCTIONAL GATE BOX COMPLETE

Weight3.234735 lb

B10D0,13 x 10⁶

Mission time20 y

PFHD3.7 x 10⁻⁹

Category4

Product version numberV4.0.0

Performance LevelPL e

VersionIlluminated push buttons

Colorwhite

Switching element1NO

Assignment diagramC2

Power supply LED24 V DC

Output voltageUB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)

Switching voltageU<sub>A</sub> V

ConnectionPlug connector RC26 (X6)

Mechanical life0,1 x 10⁶

Breaking capacitymax.0,25 W

Output current1 ... 200 mA

Type of outputSemiconductor outputs, p-switching, short circuit-proof

Installation orientationDoor hinge DIN left

Test-pulse intervalmin.100 ms

Switching current1 ... 10 mA

Ambient temperature-20 ... 55 °C

Test pulsesmax.1 ms

Current consumptionmax.80 mA ((no load on outputs))

Switching frequency0,25 Hz

Transponder codingUnicode

Operating voltage DC24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))

Housing materialReinforced plastic; die-cast zinc nickel-plated, stainless steel

Weight1,4 kg

Risk time according to EN 60947-5-3max.350 ms

Discrepancy timemax.10 ms

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

Degree of protectionIP65

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui30 V

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)

Series-

Product Class-

B10D-

Mission time-

PFHD-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Fusing-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Ambient temperature-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Mechanical life-

Shock and vibration resistance-

Housing material-

Approach speed-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Connection-

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

PFHD-

Operating distance-

Mission time-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Utilization category acc. to EN 60947-5-2-

Rated conditional short-circuit current-

Test pulses-

Test-pulse interval-

Output voltage-

Switching current-

Turn-on time-

Risk time according to EN 60947-5-3-

Type of output-

Fusing-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Degree of contamination (external, according to EN 60947-1)-

Safety class-

EMC protection requirements-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Current consumption-

Installation orientation-

Mounting distance-

Operating voltage DC-

Connection-

Switching frequency-

Ready delay-

Cable ambient temperature (dynamic)-

Degree of protection-

Mounting method-

Static bending radius-

Weight-

Shock and vibration resistance-

Cable ambient temperature (static)-

Housing material-

Dynamic bending radius-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

B10D-

Mission time-

PFHD-

Category-

Product version number-

Performance Level-

Version-

Color-

Switching element-

Assignment diagram-

Power supply LED-

Output voltage-

Switching voltage-

Connection-

Mechanical life-

Breaking capacity-

Output current-

Type of output-

Installation orientation-

Test-pulse interval-

Switching current-

Ambient temperature-

Test pulses-

Current consumption-

Switching frequency-

Transponder coding-

Operating voltage DC-

Housing material-

Weight-

Risk time according to EN 60947-5-3-

Discrepancy time-

Degree of contamination (external, according to EN 60947-1)-

Safety class-

Degree of protection-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Utilization category acc. to EN 60947-5-2-

SeriesMGBS-P-I-AP

Product ClassSafety System

B10D0,13 x 10⁶

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN IEC 60947-5-3

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-switching, short circuit-proof

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternatively see operating instructions)

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Output voltage0 ... 1 V DC

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)

Fusing0,25 ... 8 A

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV

Overtravel5 mm

Test-pulse intervalmin.100 ms

Ambient temperature-20 ... +55 °C

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Actuating force10 N

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialFiber glass reinforced thermoplastic

Approach speedmax.20 m/min

Degree of protectionIP65 (Screwed tight plug connector/mating component)

Switching frequencymax.0,5 Hz

Weight1,25 kg

Ready delaymax.1 s

Connection2 plug connectors M12, 5-pin

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

PFHD-

Operating distance-

Mission time-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Utilization category acc. to EN 60947-5-2-

Rated conditional short-circuit current-

Test pulses-

Test-pulse interval-

Output voltage-

Switching current-

Turn-on time-

Risk time according to EN 60947-5-3-

Type of output-

Fusing-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Degree of contamination (external, according to EN 60947-1)-

Safety class-

EMC protection requirements-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Current consumption-

Installation orientation-

Mounting distance-

Operating voltage DC-

Connection-

Switching frequency-

Ready delay-

Cable ambient temperature (dynamic)-

Degree of protection-

Mounting method-

Static bending radius-

Weight-

Shock and vibration resistance-

Cable ambient temperature (static)-

Housing material-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

B10D-

Mission time-

PFHD-

Category-

Product version number-

Performance Level-

Version-

Color-

Switching element-

Assignment diagram-

Power supply LED-

Output voltage-

Switching voltage-

Connection-

Mechanical life-

Breaking capacity-

Output current-

Type of output-

Installation orientation-

Test-pulse interval-

Switching current-

Ambient temperature-

Test pulses-

Current consumption-

Switching frequency-

Transponder coding-

Operating voltage DC-

Housing material-

Weight-

Risk time according to EN 60947-5-3-

Discrepancy time-

Degree of contamination (external, according to EN 60947-1)-

Safety class-

Degree of protection-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Utilization category acc. to EN 60947-5-2-

SeriesCES-AR

Product ClassSafety System

B10D-

Mission time-

PFHD-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Fusing-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Ambient temperature-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Mechanical life-

Shock and vibration resistance-

Housing material-

Approach speed-

Degree of protection-

Switching frequency-

Weight-

Ready delay-

Connection-

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

PFHD1.9 x 10⁻⁹

Operating distance19 mm

Mission time20

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)

Rated conditional short-circuit current100 A

Test pulsesmax.1 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)

Test-pulse intervalmin.140 ms

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-proof

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-3

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.1 Nm

Current consumptionmax.50 mA (Without taking into account the load currents on the monitoring output and the safety outputs)

Installation orientationAny

Mounting distancemin.120 mm

Operating voltage DC24 V DC 15% ... 15% Regulated, residual ripple < 5 %

ConnectionConnection cable PUR, length 1m with plug connector M12 8-pin

Switching frequencymax.1 Hz

Ready delay10 s

Cable ambient temperature (dynamic)-25 ... 65 °C

Degree of protectionIP67

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Weight0,09 kg

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Housing materialPlastic, PBT

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 110260?
The price of 110260 on MQ Automation is $2,063.29. Order now.

Out if stock but available for backorder.

110260 Euchner - MULTIFUNCTIONAL GATE BOX COMPLETE

What can I help you find today?

Recommended parts