About the manufacturer: Euchner is one of the manufacturers that offers Electronic Components that you can order at MQ Automation site. As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Check out the 109045 Euchner price in the box on the right side or send a quick quote.

Product Details

  • Assured operating distance Sao
    min.10 mm
  • Switching hysteresis
    min.1 mm
  • Assured release distance Sar
    max.60 mm
  • Operating distance
    15 mm
  • Mission time
    20
  • PFHD
    1.9 x 10⁻⁹
  • Category
    4
  • Performance Level
    PL e
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Discrepancy time
    max.10 ms
  • Repeat accuracy R
    ≤ 10
  • Rated conditional short-circuit current
    100 A
  • Off-state current Ir
    max.0,25 mA
  • Test-pulse interval
    min.140 ms
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Type of output
    p-switching, short circuit-proof
  • Switching current
    max.50 mA
  • Output voltage
    0,8 x UB ... UB V DC
  • Test pulses
    max.1 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Turn-on time
    max.400 ms
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Rated insulation voltage Ui
    75 V
  • Fusing
    0,25 ... 8 A
  • Current consumption
    max.50 mA (Without taking into account the load currents on the monitoring output and the safety outputs)
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Operating voltage DC
    24 V DC 15% ... 15% Regulated, residual ripple < 5 %
  • Connection
    connection cable PUR, length 5m
  • Switching frequency
    max.1 Hz
  • Mounting method
    Surface mounting on metal
  • Ready delay
    10 s
  • Tightening torque
    max.1 Nm
  • Weight
    0,2 kg
  • Degree of protection
    IP67, IP69K
  • Static bending radius
    5 x cable diameter
  • Cable ambient temperature (dynamic)
    -25 ... 65 °C
  • Installation orientation
    Any
  • Dynamic bending radius
    10 x cable diameter
  • Mounting distance
    min.120 mm
  • Housing material
    Plastic, PBT
  • Cable ambient temperature (static)
    -30 ... 65 °C
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Relevant products

What can I help you find today?

Recommended parts