109044 Euchner Electronic Components

109044 on MQ Automation
Euchner

Part#:109044

Manufacturer:Euchner

Category:Electronic Components

Product Lifecycle:Active

Get a quick Quote!

Non-contact safety switch CES-AR-CR2-..., with flying lead, PUR

About the manufacturer: Euchner is one of the manufacturers that offers Electronic Components that you can order at MQ Automation site. As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Check out the 109044 Euchner price in the box on the right side or send a quick quote.

Product Details

  • Switching hysteresis
    min.1 mm
  • Assured operating distance Sao
    min.14 mm
  • Category
    4
  • Operating distance
    19 mm
  • Mission time
    20
  • Assured release distance Sar
    max.60 mm
  • Performance Level
    PL e
  • PFHD
    1.9 x 10⁻⁹
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Discrepancy time
    max.10 ms
  • Repeat accuracy R
    ≤ 10
  • Type of output
    p-switching, short circuit-proof
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Off-state current Ir
    max.0,25 mA
  • Test-pulse interval
    min.140 ms
  • Rated conditional short-circuit current
    100 A
  • Test pulses
    max.1 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Output voltage
    0,8 x UB ... UB V DC
  • Switching current
    max.50 mA
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Safety class
    III
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Turn-on time
    max.400 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated insulation voltage Ui
    75 V
  • Fusing
    0,25 ... 8 A
  • Operating voltage DC
    24 V DC 15% ... 15% Regulated, residual ripple < 5 %
  • Current consumption
    max.50 mA (Without taking into account the load currents on the monitoring output and the safety outputs)
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Connection
    connection cable PUR, length 5m
  • Mounting distance
    min.120 mm
  • Switching frequency
    max.1 Hz
  • Ready delay
    10 s
  • Tightening torque
    max.1 Nm
  • Installation orientation
    Any
  • Cable ambient temperature (dynamic)
    -25 ... 65 °C
  • Dynamic bending radius
    10 x cable diameter
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Mounting method
    Surface mounting on metal
  • Cable ambient temperature (static)
    -30 ... 65 °C
  • Degree of protection
    IP67, IP69K
  • Housing material
    Plastic, PBT
  • Weight
    0,2 kg
  • Static bending radius
    5 x cable diameter

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.