105139 Euchner Safety Proximity Sensors

105139 on MQ Automation
Euchner
  • 105139
  • 105139
  • 105139

Part#:105139

Alt. Part#:CES-AZ-UES-01B

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

105139 Euchner - Evaluation unit CES-AZ-UES-01B (for 1 read head)

Product Details

  • Weight
    0.50485798 lb
  • Series
    CES-AZ evaluation
  • Product Class
    Safety System
  • Distance s, actuator
    min.3 mm
  • Switching hysteresis
    min.1 mm (These values apply for surface installation of the read head in metal and the non-metallic installation of the actuator.)
  • Assured operating distance Sao
    min.5 mm (This value applies for the surface installation of the read head in metal and the non-metallic installation of the actuator.)
  • Assured release distance Sar
    max.25 mm (This value applies for the surface installation of the read head in metal and the non-metallic installation of the actuator.)
  • Operating distance
    8 mm A distance of s = 3 mm must be maintained for a side approach direction. (This value applies for the surface installation of the read head in metal and the non-metallic installation of the actuator.)
  • Mission time
    20 y (This value is dependent on the number of switching cycles and the switching current.)
  • Number of switching cycles
    max.153000 1/Jahr
  • PFHD
    1.9 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
  • Diagnostic Coverage (DC)
    99 %
  • Performance Level
    PL e (This value is dependent on the number of switching cycles and the switching current.)
  • Category
    4 (This value is dependent on the number of switching cycles and the switching current.)
  • Repeat accuracy R
    max.10 %
  • For the approval acc. to UL the following applies
    (Operation only with UL class 2 power supply or equivalent measures.)
  • LED indicator
    Status LED
  • Input current
    5 ... 8 ... 10 mA
  • Input voltage
    15 ... UB V DC
  • Output voltage
    0,8 x UB ... UB V DC
  • Output current
    max.20 mA
  • Rated impulse withstand voltage Uimp
    4 kV
  • Rated conditional short-circuit current
    100 A
  • Discrepancy time
    max.25 ms
  • Switching load
    Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A
  • Rated insulation voltage Ui
    250 V
  • Utilization category acc. to EN 60947-5-1
    230 V 2 A
  • Current via feedback loop
    5 ... 8 ... 10 mA
  • Switching current
    10 ... 2000 mA
  • permissible resistance in feedback loop
    max.600 Ω
  • Connection cross-section
    0,25 ... 2,5 mm²
  • Type of output
    Relay contacts, floating
  • Degree of contamination (external, according to EN 60947-1)
    2
  • EMC protection requirements
    In acc. with EN 60947-5-3
  • Current consumption
    150 mA (Without taking into account the load currents on the monitoring outputs)
  • Mechanical life
    10 x 10⁶
  • Operating voltage DC
    21 ... 24 ... 27 V DC Regulated, residual ripple < 5 %
  • Fusing
    0,25 ... 8 A
  • Number of safety contacts
    2 Relays with internally monitored contacts
  • Connection
    Plug-in connection terminals, coded (Terminals not included)
  • Dwell time
    min.3 s (The dwell time is the time that the actuator must be inside or outside the operating distance.)
  • Switching frequency
    max.0,25 Hz (In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed)
  • Reaction time
    max.210 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3,
  • Ready delay
    10 ... 12 s (After the operating voltage is switched on, the relay outputs are switched off and the door monitoring output is set LOW during the ready delay. For the visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15
  • Number of read heads
    1 read head can be connected
  • Housing material
    Plastic PA6.6
  • Ambient temperature
    -20 ... 55 °C
  • Degree of protection
    IP20
  • Atmospheric humidity
    max.80 % rH
  • Mounting distance
    min.10 mm (If several evaluation units are mounted side by side in a control cabinet without air circulation (e.g. fan), a minimum distance of 10 mm must be maintained between the evaluation units. The distance enables heat from the evaluation unit to di
  • Weight
    0,2 kg
  • Mounting method
    Mounting rail 35mm according to DIN EN 60715 TH35

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 105139 on MQ Automation is $398.85. Order now.


About the product

1 read head can be connected;2 safety outputs (relay contacts with 2 internally connected NO contacts per output);Start button and feedback loop can be connected;Multicode;Plug-in connection terminals;Category 4 / PL e according to EN ISO 13849-1


Manufacturer warranty

105139 Euchner

$398.85

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$398.85

$398.85 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 105139 with other products

Weight

Series

Product Class

Distance s, actuator

Switching hysteresis

Assured operating distanc...

Assured release distance ...

Operating distance

Mission time

Number of switching cycle...

PFHD

Diagnostic Coverage (DC)

Performance Level

Category

Repeat accuracy R

For the approval acc. to ...

LED indicator

Input current

Input voltage

Output voltage

Output current

Rated impulse withstand v...

Rated conditional short-c...

Discrepancy time

Switching load

Rated insulation voltage ...

Utilization category acc....

Current via feedback loop

Switching current

permissible resistance in...

Connection cross-section

Type of output

Degree of contamination (...

EMC protection requiremen...

Current consumption

Mechanical life

Operating voltage DC

Fusing

Number of safety contacts

Connection

Dwell time

Switching frequency

Reaction time

Ready delay

Number of read heads

Housing material

Ambient temperature

Degree of protection

Atmospheric humidity

Mounting distance

Mounting method

Off-state current Ir

Utilization category acc....

Test pulses

Test-pulse interval

Turn-on time

Risk time according to EN...

Safety class

Extension of risk time ac...

Tightening torque

Installation orientation

Cable ambient temperature...

Static bending radius

Shock and vibration resis...

Cable ambient temperature...

Dynamic bending radius

Additional feature

Material

Selected product

105139
0 in stock
105139
Euchner

105139 Euchner - Evaluation unit CES-AZ-UES-01B (for 1 read head)

Weight0.50485798 lb

SeriesCES-AZ evaluation

Product ClassSafety System

Distance s, actuatormin.3 mm

Switching hysteresismin.1 mm (These values appl...

Assured operating distance Saomin.5 mm (This value applie...

Assured release distance Sarmax.25 mm (This value appli...

Operating distance8 mm A distance of s = 3 m...

Mission time20 y (This value is depend...

Number of switching cyclesmax.153000 1/Jahr

PFHD1.9 x 10⁻⁸ (This value is d...

Diagnostic Coverage (DC)99 %

Performance LevelPL e (This value is depende...

Category4 (This value is dependent...

Repeat accuracy Rmax.10 %

For the approval acc. to UL the following applies(Operation only with UL clas...

LED indicatorStatus LED

Input current5 ... 8 ... 10 mA

Input voltage15 ... UB V DC

Output voltage0,8 x UB ... UB V DC

Output currentmax.20 mA

Rated impulse withstand voltage Uimp4 kV

Rated conditional short-circuit current100 A

Discrepancy timemax.25 ms

Switching loadClass 2 max. 30 V AC / Class...

Rated insulation voltage Ui250 V

Utilization category acc. to EN 60947-5-1230 V 2 A

Current via feedback loop5 ... 8 ... 10 mA

Switching current10 ... 2000 mA

permissible resistance in feedback loopmax.600 Ω

Connection cross-section0,25 ... 2,5 mm²

Type of outputRelay contacts, floating

Degree of contamination (external, according to EN 60947-1)2

EMC protection requirementsIn acc. with EN 60947-5-3

Current consumption150 mA (Without taking into...

Mechanical life10 x 10⁶

Operating voltage DC21 ... 24 ... 27 V DC Regu...

Fusing0,25 ... 8 A

Number of safety contacts2 Relays with internally ...

ConnectionPlug-in connection terminals...

Dwell timemin.3 s (The dwell time is ...

Switching frequencymax.0,25 Hz (In case of mon...

Reaction timemax.210 ms (Corresponds to ...

Ready delay10 ... 12 s (After the oper...

Number of read heads1 read head can be connected

Housing materialPlastic PA6.6

Ambient temperature-20 ... 55 °C

Degree of protectionIP20

Atmospheric humiditymax.80 % rH

Mounting distancemin.10 mm (If several evalu...

Mounting methodMounting rail 35mm according...

Off-state current Ir-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Installation orientation-

Cable ambient temperature (dynamic)-

Static bending radius-

Shock and vibration resistance-

Cable ambient temperature (static)-

Dynamic bending radius-

Additional feature-

Material-

105748
3 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Distance s, actuator-

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

Mission time20

Number of switching cycles-

PFHD1.9 x 10⁻⁹

Diagnostic Coverage (DC)-

Performance LevelPL e

Category4

Repeat accuracy R≤ 10

For the approval acc. to UL the following appliesOperation only with UL class...

LED indicator-

Input current-

Input voltage-

Output voltage0,8 x UB ... UB V DC

Output current-

Rated impulse withstand voltage Uimp1,5 kV

Rated conditional short-circuit current100 A

Discrepancy timemax.10 ms

Switching load-

Rated insulation voltage Ui75 V

Utilization category acc. to EN 60947-5-1-

Current via feedback loop-

Switching currentmax.50 mA

permissible resistance in feedback loop-

Connection cross-section-

Type of outputp-switching, short circuit-p...

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Current consumptionmax.50 mA (Without taking i...

Mechanical life-

Operating voltage DC24 V DC 15% ... 15% Regu...

Fusing0,25 ... 8 A

Number of safety contacts-

ConnectionConnection cable PUR, length...

Dwell time-

Switching frequencymax.1 Hz

Reaction time-

Ready delay10 s

Number of read heads-

Housing materialPlastic, PBT

Ambient temperature-

Degree of protectionIP67

Atmospheric humidity-

Mounting distancemin.120 mm

Mounting methodSurface mounting on metal

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.1 Nm

Installation orientationAny

Cable ambient temperature (dynamic)-25 ... 65 °C

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Additional feature-

Material-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SeriesCES-AR

Product ClassSafety System

Distance s, actuator-

Switching hysteresismin.1 mm

Assured operating distance Sao6

Assured release distance Sarmax.60 mm

Operating distance11 mm

Mission time20

Number of switching cycles-

PFHD4.1 x 10⁻⁹

Diagnostic Coverage (DC)-

Performance LevelPL e

Category4

Repeat accuracy R≤ 10

For the approval acc. to UL the following appliesOperation only with UL class...

LED indicator-

Input current-

Input voltage-

Output voltage0,8 x UB ... UB V DC

Output current-

Rated impulse withstand voltage Uimp1,5 kV

Rated conditional short-circuit current100 A

Discrepancy timemax.10 ms

Switching load-

Rated insulation voltage Ui300 V

Utilization category acc. to EN 60947-5-1-

Current via feedback loop-

Switching currentmax.50 mA

permissible resistance in feedback loop-

Connection cross-section-

Type of outputSemiconductor output, p-swit...

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Current consumptionmax.35 mA (Without taking i...

Mechanical life-

Operating voltage DC24 V DC 15% ... 15% Regu...

Fusing0,25 ... 8 A

Number of safety contacts-

ConnectionConnection cable PUR, length...

Dwell time-

Switching frequencymax.1 Hz

Reaction time-

Ready delay10 s

Number of read heads-

Housing materialPlastic, PBT

Ambient temperature-

Degree of protectionIP67

Atmospheric humidity-

Mounting distancemin.80 mm

Mounting methodSurface mounting on metal

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.0,8 Nm

Installation orientationAny

Cable ambient temperature (dynamic)-25 ... 65 °C

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Additional featureRubber support included

MaterialNBR 80 ±5 Shore

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

FAQ

What is the price of 105139?
The price of 105139 on MQ Automation is $398.85. Order now.

Out if stock but available for backorder.

105139 Euchner - Evaluation unit CES-AZ-UES-01B (for 1 read head)

What can I help you find today?

Recommended parts