105141 Euchner Safety Proximity Sensors


Part#:105141
Alt. Part#:CES-AZ-UES-04B
Manufacturer:Euchner
Category:Safety Proximity Sensors
Product Lifecycle:Active
Mar 12, 2025
Product description
105141 Euchner - Evaluation unit CES-AZ-UES-04B (for 4 read heads)
Product Details
- Weight 0.65477214 lb
- Series CES-AZ evaluation
- Product Class Safety System
- Switching hysteresis min.0,5 mm (These values apply for surface installation of the read head and the actuator.)
- Assured operating distance Sao min.10 mm (These values apply for surface installation of the read head and the actuator.)
- Assured release distance Sar max.32 mm
- Number of switching cycles max.760000 1/Jahr
- Mission time 20 y (This value is dependent on the number of switching cycles and the switching current.)
- Operating distance 16 mm (These values apply for surface installation of the read head and the actuator.)
- Distance s, actuator min.5 mm
- Diagnostic Coverage (DC) 99 %
- PFHD 1.9 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
- Performance Level PL e (This value is dependent on the number of switching cycles and the switching current.)
- Category 4 (This value is dependent on the number of switching cycles and the switching current.)
- For the approval acc. to UL the following applies (Operation only with UL class 2 power supply or equivalent measures.)
- Output current max.20 mA
- Repeat accuracy R max.10 %
- Input current 5 ... 8 ... 10 mA
- Input voltage 15 ... UB V DC
- LED indicator Status LED
- Discrepancy time max.25 ms
- Rated conditional short-circuit current 100 A
- Output voltage 0,8 x UB ... UB V DC
- Rated insulation voltage Ui 250 V
- Rated impulse withstand voltage Uimp 4 kV
- Switching load Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A
- Switching current 1 ... 300 mA
- Type of output Relay contacts, floating
- Utilization category acc. to EN 60947-5-1 230 V 2 A
- Current via feedback loop 5 ... 8 ... 10 mA
- Degree of contamination (external, according to EN 60947-1) 2
- permissible resistance in feedback loop max.600 Ω
- Connection cross-section 0,25 ... 2,5 mm²
- Number of safety contacts 2 Relays with internally monitored contacts
- EMC protection requirements In acc. with EN 60947-5-3
- Current consumption 150 mA (Without taking into account the load currents on the monitoring outputs)
- Mechanical life 10 x 10⁶
- Fusing 0,25 ... 8 A
- Operating voltage DC 21 ... 24 ... 27 V DC Regulated, residual ripple < 5 %
- Dwell time min.3 s (The dwell time is the time that the actuator must be inside or outside the operating distance.)
- Connection Plug-in connection terminals, coded (Terminals not included)
- Mounting distance min.10 mm (If several evaluation units are mounted side by side in a control cabinet without air circulation (e.g. fan), a minimum distance of 10 mm must be maintained between the evaluation units. The distance enables heat from the evaluation unit to di
- Reaction time max.210 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3,
- Number of read heads Max. 4 read heads can be connected
- Switching frequency max.0,25 Hz (In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed.)
- Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
- Housing material Plastic PA6.6
- Ambient temperature -20 ... 55 °C
- Ready delay 10 ... 12 s (After the operating voltage is switched on, the relay outputs are switched off and the door monitoring outputs are set LOW during the ready delay. For the visual indication of the delay, the green STATE LED flashes at a frequency of approx.
- Degree of protection IP20
- Atmospheric humidity max.80 % rH
- Weight 0,25 kg
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 105141 on MQ Automation is $718.41. Order now.
About the product
4 read heads can be connected;2 safety outputs (relay contacts with 2 internally connected NO contacts per output);Start button and feedback loop can be connected;Multicode;Plug-in connection terminals;Category 4 / PL e according to EN ISO 13849-1
This item can ship in 3-5 days!
Manufacturer warranty
105141 Euchner
$718.41
Your price can be lower.
Log in or Create account to check your discount
Stock:
Select Qty:
$718.41
$718.41 each
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Relevant products
FAQ
What is the price of 105141?
The price of 105141 on MQ Automation is $718.41. Order now.
Out if stock but available for backorder.
105141 Euchner - Evaluation unit CES-AZ-UES-04B (for 4 read heads)
What can I help you find today?