105141 Euchner Safety Proximity Sensors

105141 on MQ Automation
Euchner

Part#:105141

Alt. Part#:CES-AZ-UES-04B

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

9 in stock

Mar 12, 2025

Product description

105141 Euchner - Evaluation unit CES-AZ-UES-04B (for 4 read heads)

Product Details

  • Weight
    0.65477214 lb
  • Series
    CES-AZ evaluation
  • Product Class
    Safety System
  • Switching hysteresis
    min.0,5 mm (These values apply for surface installation of the read head and the actuator.)
  • Assured operating distance Sao
    min.10 mm (These values apply for surface installation of the read head and the actuator.)
  • Assured release distance Sar
    max.32 mm
  • Number of switching cycles
    max.760000 1/Jahr
  • Mission time
    20 y (This value is dependent on the number of switching cycles and the switching current.)
  • Operating distance
    16 mm (These values apply for surface installation of the read head and the actuator.)
  • Distance s, actuator
    min.5 mm
  • Diagnostic Coverage (DC)
    99 %
  • PFHD
    1.9 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
  • Performance Level
    PL e (This value is dependent on the number of switching cycles and the switching current.)
  • Category
    4 (This value is dependent on the number of switching cycles and the switching current.)
  • For the approval acc. to UL the following applies
    (Operation only with UL class 2 power supply or equivalent measures.)
  • Output current
    max.20 mA
  • Repeat accuracy R
    max.10 %
  • Input current
    5 ... 8 ... 10 mA
  • Input voltage
    15 ... UB V DC
  • LED indicator
    Status LED
  • Discrepancy time
    max.25 ms
  • Rated conditional short-circuit current
    100 A
  • Output voltage
    0,8 x UB ... UB V DC
  • Rated insulation voltage Ui
    250 V
  • Rated impulse withstand voltage Uimp
    4 kV
  • Switching load
    Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A
  • Switching current
    1 ... 300 mA
  • Type of output
    Relay contacts, floating
  • Utilization category acc. to EN 60947-5-1
    230 V 2 A
  • Current via feedback loop
    5 ... 8 ... 10 mA
  • Degree of contamination (external, according to EN 60947-1)
    2
  • permissible resistance in feedback loop
    max.600 Ω
  • Connection cross-section
    0,25 ... 2,5 mm²
  • Number of safety contacts
    2 Relays with internally monitored contacts
  • EMC protection requirements
    In acc. with EN 60947-5-3
  • Current consumption
    150 mA (Without taking into account the load currents on the monitoring outputs)
  • Mechanical life
    10 x 10⁶
  • Fusing
    0,25 ... 8 A
  • Operating voltage DC
    21 ... 24 ... 27 V DC Regulated, residual ripple < 5 %
  • Dwell time
    min.3 s (The dwell time is the time that the actuator must be inside or outside the operating distance.)
  • Connection
    Plug-in connection terminals, coded (Terminals not included)
  • Mounting distance
    min.10 mm (If several evaluation units are mounted side by side in a control cabinet without air circulation (e.g. fan), a minimum distance of 10 mm must be maintained between the evaluation units. The distance enables heat from the evaluation unit to di
  • Reaction time
    max.210 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3,
  • Number of read heads
    Max. 4 read heads can be connected
  • Switching frequency
    max.0,25 Hz (In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed.)
  • Mounting method
    Mounting rail 35mm according to DIN EN 60715 TH35
  • Housing material
    Plastic PA6.6
  • Ambient temperature
    -20 ... 55 °C
  • Ready delay
    10 ... 12 s (After the operating voltage is switched on, the relay outputs are switched off and the door monitoring outputs are set LOW during the ready delay. For the visual indication of the delay, the green STATE LED flashes at a frequency of approx.
  • Degree of protection
    IP20
  • Atmospheric humidity
    max.80 % rH
  • Weight
    0,25 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 105141 on MQ Automation is $718.41. Order now.


About the product

4 read heads can be connected;2 safety outputs (relay contacts with 2 internally connected NO contacts per output);Start button and feedback loop can be connected;Multicode;Plug-in connection terminals;Category 4 / PL e according to EN ISO 13849-1


This item can ship in 3-5 days!

Manufacturer warranty

105141 Euchner

$718.41

Your price can be lower.
Log in or Create account to check your discount

Stock:

9

Select Qty:

$718.41

$718.41 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

FAQ

What is the price of 105141?
The price of 105141 on MQ Automation is $718.41. Order now.

Out if stock but available for backorder.

105141 Euchner - Evaluation unit CES-AZ-UES-04B (for 4 read heads)

What can I help you find today?

Recommended parts