099258 Euchner Safety Accessories


Part#:099258
Alt. Part#:CMS-E-FR
Manufacturer:Euchner
Category:Safety Accessories
Product Lifecycle:Active
Mar 12, 2025
Product description
099258 Euchner - Evaluation unit CMS-E-FR, 2 safety contacts, 1 auxiliary contact, 6 monitoring outputs, 1 feedback loop can be connected
Product Details
- Weight 0.76941238 lb
- Series CMS
- Product Class Safety System
- Assured operating distance Sao min.6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
- Assured release distance Sar max.14 mm (The assured switch-off distance sar corresponds to the reset distance.)
- Number of switching cycles max.70000 1/Jahr
- Center offset 2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
- PFHD 2.5 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
- Mission time 20 y (This value is dependent on the number of switching cycles and the switching current.)
- Performance Level PL e (This value is dependent on the number of switching cycles and the switching current.)
- Category 4 (This value is dependent on the number of switching cycles and the switching current.)
- In compliance with EN ISO 13849-1: 2015; EN ISO 13849-2:2012; EN 50178: 1997; EN 60204-1: 2006/A1: 2009; EN ISO 13850: 2015; EN 14119: 2013; EN 6100-2-6: 2005; EN 6100-6-3: 2007/A1: 2011; EN 60947-5-3: 2013
- Risk time according to EN 60947-5-3 max.20 ms
- Breaking capacity (VA) max.720 VA
- Switching load Input: 24V AC/DC ; output: 30V AC, 24V DC
- Utilization category acc. to EN 60947-5-1 0.9A , 240V and 0.9A , 24V (Max. switching current per contact)
- Switching current 10 ... 3000 mA
- Switching voltage max.240 V
- Type of output Relay contacts, floating (2 NO contact pairs)
- LED indicator 1 indicator LED Power, 2 output LEDs and 6 status indicators for the read heads
- Connection cross-section 0,14 ... 2,5 mm²
- Degree of contamination (external, according to EN 60947-1) 2
- Rated insulation voltage Ui 250 V
- Current consumption 10 ... 120 mA
- Fusing 0,75 A Automatically resetting fuse PTC
- Operating voltage 24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
- Number of monitoring outputs 6
- Number of auxiliary contacts 1
- Number of safety contacts 2
- Housing material Polyamide PA6.6
- Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
- Connection Connection terminals
- Mechanical life 10 x 10⁶
- Ambient temperature 0 ... 55 °C
- Degree of protection Terminals IP20 / housing IP40
- Weight 0,3 kg
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 099258 on MQ Automation is $409.44. Order now.
About the product
Up to 6 read heads can be connected;2 safety contacts;1 auxiliary contact;6 monitoring outputs;1 feedback loop can be connected;Start automatic/monitored/not monitored
This item can ship in 3-5 days!
Manufacturer warranty
099258 Euchner
$409.44
Your price can be lower.
Log in or Create account to check your discount
Stock:
Select Qty:
$409.44
$409.44 each
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Relevant products
FAQ
What is the price of 099258?
The price of 099258 on MQ Automation is $409.44. Order now.
Out if stock but available for backorder.
099258 Euchner - Evaluation unit CMS-E-FR, 2 safety contacts, 1 auxiliary contact, 6 monitoring outputs, 1 feedback loop can be connected
What can I help you find today?