BNS-Y-02 Schmersal Safety Accessories

BNS-Y-02 on MQ Automation
Schmersal

Part#:BNS-Y-02

Alt. Part#:101194060

Manufacturer:Schmersal

Category:Safety Accessories

Product Lifecycle:Active

Product description

BNS-Y-02 Schmersal - Pre-wired cable; enables the interconnection and the connection of BNS safety sensors to a common safety monitoring module; for BNS 33, BNS 36, BNS 260 (with 2 NC)

Product Details

  • Ambient temperature, maximum
    +70 °C
  • Diameter of the ISO-thread
    M8
  • Ambient temperature, minimum
    -25 °C
  • Versions
    Y-adapter
  • Mechanical life, minimum
    100 Cycles
  • Degree of protection
    IP67
  • Connector (electric)
    2 x Female connector, 4-pole, 1 x Male connector, 4-pole
  • Gross weight
    23 g
  • Length
    10 mm
  • Width
    23.5 mm
  • Height
    31 mm

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


About the product

BNS-Y-02 Schmersal - Pre-wired cable; enables the interconnection and the connection of BNS safety sensors to a common safety monitoring module; for BNS 33, BNS 36, BNS 260 (with 2 NC)



BNS-Y-02 Related Documents

Manufacturer warranty

BNS-Y-02 Schmersal

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare BNS-Y-02 with other products

Ambient temperature, maximum

Diameter of the ISO-thread

Ambient temperature, minimum

Versions

Mechanical life, minimum

Degree of protection

Connector (electric)

Gross weight

Length

Width

Height

Interfering radiation

EMC rating

Current, Utilisation category DC12

Voltage, Utilisation category DC13

Current, Utilisation category DC13

Versions

Voltage drop Ud, maximum

Current leakage Ir

Rated operating current (safety outputs)

Operating current

Required rated short-circuit current to EN 60947-5-1

Rated operating voltage, minimum

Voltage type

Rated operating voltage

No-load supply current I0

Protection rating

Overvoltage category

Restistance to shock

Material temperature resistance of the cable (in motion), minimum

Resistance to vibrations to EN 60068-2-6

Material temperature resistance (long-term), maximum

Degree of protection

Ambient temperature, minimum

Terminal Connector

Note (Repeat accuracy R)

Number of fail-safe digital outputs

Short-circuit recognition

Diagnostic output

Gross weight

Active area

Voltage, Utilisation category DC12

Switching frequency, approx.

Output current, (fail-safe output), maximum

Rated operating voltage, maximum

Degree of pollution to VDE 0100

Rated impulse withstand voltage Uimp

Rated insulation voltage Ui

Material temperature resistance of the cable (at rest), minimum

Storage and transport temperature, maximum

Storage and transport temperature, minimum

Ambient temperature, maximum

Ensured switch distance ON Sao

Note

Length of sensor

Height of sensor

Width of sensor

Ensured switch distance OFF Sar

Switch distance

Hysteresis (Switch distance), maximum

Repeat accuracy R R

Mounting

Actuating panels

Number of semi-conductor outputs with signaling function

Number of LEDs

Cascadable

Integral System Diagnostics, status

Duration of risk, maximum

Safety functions

Time to readiness, maximum

Reaction time, maximum

Short circuit detection

Enclosure material

Sensor topology

Active principle

Standards

Installation conditions (mechanical)

Coding level according to ISO 14119

general information

Housing construction form

Current, Utilisation category DC13

Voltage, Utilisation category DC13

Current, Utilisation category AC-15

Switching principle

Switching element

Thermal test current

Ambient temperature, maximum

Voltage, Utilisation category AC15

Degree of protection

Rated insulation voltage Ui

Rated impulse withstand voltage Uimp

Ambient temperature, minimum

Height of sensor

Cable section, maximum

Terminal Connector

Length of sensor

Width of sensor

Cable entry

Cable section, minimum

Actuating speed, maximum

Positive break force, minimum

positive break travel

Mechanical life, minimum

Number of cable glands

Coding level according to ISO 14119

Material of the contacts, electrical

Latching force

Number of safety contacts

Gross weight

Enclosure material

Number of auxiliary contacts

Selected product

BNS-Y-02
0 in stock
BNS-Y-02
Schmersal

BNS-Y-02 Schmersal - Pre-wired cable; enables the interconnection and the connection of BNS safety s...

Ambient temperature, maximum+70 °C

Diameter of the ISO-threadM8

Ambient temperature, minimum-25 °C

VersionsY-adapter

Mechanical life, minimum100 Cycles

Degree of protectionIP67

Connector (electric)2 x Female connector, 4-pole, 1 x Male connector, 4-pole

Gross weight23 g

Length10 mm

Width23.5 mm

Height31 mm

Interfering radiation-

EMC rating-

Current, Utilisation category DC12-

Voltage, Utilisation category DC13-

Current, Utilisation category DC13-

Versions-

Voltage drop Ud, maximum-

Current leakage Ir-

Rated operating current (safety outputs)-

Operating current-

Required rated short-circuit current to EN 60947-5-1-

Rated operating voltage, minimum-

Voltage type-

Rated operating voltage-

No-load supply current I0-

Protection rating-

Overvoltage category-

Restistance to shock-

Material temperature resistance of the cable (in motion), minimum-

Resistance to vibrations to EN 60068-2-6-

Material temperature resistance (long-term), maximum-

Degree of protection-

Ambient temperature, minimum-

Terminal Connector-

Note (Repeat accuracy R)-

Number of fail-safe digital outputs-

Short-circuit recognition-

Diagnostic output-

Gross weight-

Active area-

Voltage, Utilisation category DC12-

Switching frequency, approx.-

Output current, (fail-safe output), maximum-

Rated operating voltage, maximum-

Degree of pollution to VDE 0100-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Material temperature resistance of the cable (at rest), minimum-

Storage and transport temperature, maximum-

Storage and transport temperature, minimum-

Ambient temperature, maximum-

Ensured switch distance ON Sao-

Note-

Length of sensor-

Height of sensor-

Width of sensor-

Ensured switch distance OFF Sar-

Switch distance-

Hysteresis (Switch distance), maximum-

Repeat accuracy R R-

Mounting-

Actuating panels-

Number of semi-conductor outputs with signaling function-

Number of LEDs-

Cascadable-

Integral System Diagnostics, status-

Duration of risk, maximum-

Safety functions-

Time to readiness, maximum-

Reaction time, maximum-

Short circuit detection-

Enclosure material-

Sensor topology-

Active principle-

Standards-

Installation conditions (mechanical)-

Coding level according to ISO 14119-

general information-

Housing construction form-

Current, Utilisation category DC13-

Voltage, Utilisation category DC13-

Current, Utilisation category AC-15-

Switching principle-

Switching element-

Thermal test current-

Ambient temperature, maximum-

Voltage, Utilisation category AC15-

Degree of protection-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Ambient temperature, minimum-

Height of sensor-

Cable section, maximum-

Terminal Connector-

Length of sensor-

Width of sensor-

Cable entry-

Cable section, minimum-

Actuating speed, maximum-

Positive break force, minimum-

positive break travel-

Mechanical life, minimum-

Number of cable glands-

Coding level according to ISO 14119-

Material of the contacts, electrical-

Latching force-

Number of safety contacts-

Gross weight-

Enclosure material-

Number of auxiliary contacts-

RSS 36-D-ST
1 in stock
RSS 36-D-ST
Schmersal

Safety sensors; Electronic safety sensors; Universal coding with RFID technology; 1 x connector sock...

Ambient temperature, maximum-

Diameter of the ISO-thread-

Ambient temperature, minimum-

Versions-

Mechanical life, minimum-

Degree of protection-

Connector (electric)-

Gross weight-

Length-

Width-

Height-

Interfering radiationIEC 61000-6-4

EMC ratingIEC 60947-3

Current, Utilisation category DC120.05 A

Voltage, Utilisation category DC1324 VDC

Current, Utilisation category DC130.05 A

Versionsp-type

Voltage drop Ud, maximum2 V

Current leakage Ir0.5 mA

Rated operating current (safety outputs)250 mA

Operating current600 mA

Required rated short-circuit current to EN 60947-5-1100 A

Rated operating voltage, minimum20.4 VDC

Voltage typeDC (direct current)

Rated operating voltage24 VDC −15 % / +10 %

No-load supply current I0100 mA

Protection ratingIII

Overvoltage categoryIII

Restistance to shock30 g / 11 ms

Material temperature resistance of the cable (in motion), minimum-10 °C

Resistance to vibrations to EN 60068-2-610 … 55 Hz, amplitude 1 mm

Material temperature resistance (long-term), maximum+105 °C

Degree of protectionIP65 to EN 60529, IP67 to EN 60529, IP69 to EN 60529

Ambient temperature, minimum-25 °C

Terminal ConnectorConnector M12, 8-pole

Note (Repeat accuracy R)Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum clearance

Number of fail-safe digital outputs2

Short-circuit recognitionYes

Diagnostic outputYes

Gross weight80 g

Active arealateral

Voltage, Utilisation category DC1224 VDC

Switching frequency, approx.1 Hz

Output current, (fail-safe output), maximum0.25 A

Rated operating voltage, maximum26.4 VDC

Degree of pollution to VDE 01003

Rated impulse withstand voltage Uimp0.8 kV

Rated insulation voltage Ui32 VDC

Material temperature resistance of the cable (at rest), minimum-30 °C

Storage and transport temperature, maximum+85 °C

Storage and transport temperature, minimum-25 °C

Ambient temperature, maximum+70 °C

Ensured switch distance ON Sao10 mm

NoteThe cable section of the interconnecting cable must be observed! Cable length and cable section alter the voltage drop depending on the output current

Length of sensor22 mm

Height of sensor25 mm

Width of sensor106.3 mm

Ensured switch distance OFF Sar20 mm

Switch distance12 mm

Hysteresis (Switch distance), maximum2 mm

Repeat accuracy R R0.5 mm

MountingA screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used.

Actuating panelslateral

Number of semi-conductor outputs with signaling function1

Number of LEDs3

CascadableYes

Integral System Diagnostics, statusYes

Duration of risk, maximum200 ms

Safety functionsYes

Time to readiness, maximum2,000 ms

Reaction time, maximum100 ms

Short circuit detectionYes

Enclosure materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing

Sensor topologySensor for series wiring

Active principleRFID

StandardsIEC 60947-5-3

Installation conditions (mechanical)not flush

Coding level according to ISO 14119Low

general informationUniversal coding

Housing construction formBlock

Current, Utilisation category DC13-

Voltage, Utilisation category DC13-

Current, Utilisation category AC-15-

Switching principle-

Switching element-

Thermal test current-

Ambient temperature, maximum-

Voltage, Utilisation category AC15-

Degree of protection-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Ambient temperature, minimum-

Height of sensor-

Cable section, maximum-

Terminal Connector-

Length of sensor-

Width of sensor-

Cable entry-

Cable section, minimum-

Actuating speed, maximum-

Positive break force, minimum-

positive break travel-

Mechanical life, minimum-

Number of cable glands-

Coding level according to ISO 14119-

Material of the contacts, electrical-

Latching force-

Number of safety contacts-

Gross weight-

Enclosure material-

Number of auxiliary contacts-

AZ 16-12ZVRK-M20
4 in stock
AZ 16-12ZVRK-M20
Schmersal

Safety switch with separate actuator; 3 cable entries M 20 x 1.5; Large wiring compartment; Thermopl...

Ambient temperature, maximum-

Diameter of the ISO-thread-

Ambient temperature, minimum-

Versions-

Mechanical life, minimum-

Degree of protection-

Connector (electric)-

Gross weight-

Length-

Width-

Height-

Interfering radiation-

EMC rating-

Current, Utilisation category DC12-

Voltage, Utilisation category DC13-

Current, Utilisation category DC13-

Versions-

Voltage drop Ud, maximum-

Current leakage Ir-

Rated operating current (safety outputs)-

Operating current-

Required rated short-circuit current to EN 60947-5-1-

Rated operating voltage, minimum-

Voltage type-

Rated operating voltage-

No-load supply current I0-

Protection rating-

Overvoltage category-

Restistance to shock-

Material temperature resistance of the cable (in motion), minimum-

Resistance to vibrations to EN 60068-2-6-

Material temperature resistance (long-term), maximum-

Degree of protection-

Ambient temperature, minimum-

Terminal Connector-

Note (Repeat accuracy R)-

Number of fail-safe digital outputs-

Short-circuit recognition-

Diagnostic output-

Gross weight-

Active area-

Voltage, Utilisation category DC12-

Switching frequency, approx.-

Output current, (fail-safe output), maximum-

Rated operating voltage, maximum-

Degree of pollution to VDE 0100-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Material temperature resistance of the cable (at rest), minimum-

Storage and transport temperature, maximum-

Storage and transport temperature, minimum-

Ambient temperature, maximum-

Ensured switch distance ON Sao-

Note-

Length of sensor-

Height of sensor-

Width of sensor-

Ensured switch distance OFF Sar-

Switch distance-

Hysteresis (Switch distance), maximum-

Repeat accuracy R R-

Mounting-

Actuating panels-

Number of semi-conductor outputs with signaling function-

Number of LEDs-

Cascadable-

Integral System Diagnostics, status-

Duration of risk, maximum-

Safety functions-

Time to readiness, maximum-

Reaction time, maximum-

Short circuit detection-

Enclosure material-

Sensor topology-

Active principle-

Standards-

Installation conditions (mechanical)-

Coding level according to ISO 14119-

general information-

Housing construction form-

Current, Utilisation category DC134 A

Voltage, Utilisation category DC1324 VDC

Current, Utilisation category AC-154 A

Switching principleCreep circuit element

Switching elementNO contact, NC contact

Thermal test current10 A

Ambient temperature, maximum+80 °C

Voltage, Utilisation category AC15230 VAC

Degree of protectionIP67 to EN 60529

Rated insulation voltage Ui500 V

Rated impulse withstand voltage Uimp6 kV

Ambient temperature, minimum-30 °C

Height of sensor90 mm

Cable section, maximum2.5 mm²

Terminal ConnectorScrew connection

Length of sensor30 mm

Width of sensor52 mm

Cable entry3 x M20 x 1,5

Cable section, minimum0.25 mm²

Actuating speed, maximum2 m/s

Positive break force, minimum10 N

positive break travel8 mm

Mechanical life, minimum1,000,000 Operations

Number of cable glands3

Coding level according to ISO 14119Low

Material of the contacts, electricalSilver

Latching force30 N

Number of safety contacts2

Gross weight115 g

Enclosure materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing

Number of auxiliary contacts1

About the manufacturer

Schmersal

Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.

Recently viewed products

Relevant products

FAQ

Out if stock but available for backorder.

BNS-Y-02 Schmersal - Pre-wired cable; enables the interconnection and the connection of BNS safety sensors to a common safety monitoring module; for BNS 33, BNS 36, BNS 260 (with 2 NC)

What can I help you find today?

Recommended parts