7000-44001-8500100 Murr Elektronik Cable Assemblies

7000-44001-8500100 on MQ Automation
Murr Elektronik

Part#:7000-44001-8500100

Manufacturer:Murr Elektronik

Category:Cable Assemblies

Product Lifecycle:Active

Product description

7000-44001-8500100 Murrelektronik - M12 male 0°/M12 female 0° shielded B-cod.Profibus, PVC 1x2xAWG24 shielded vt UL/CSA 1m

Product Details

  • Weight
    83 g
  • Series
    Connector Systems
  • Product article number of manufacturer
    7000-44001-8500100
  • No. of bending cycles (C-track)
    max. 2 Mio. (25 °C)
  • Cable length
    1 m
  • Acceleration (C-track)
    max. 5 m/s²
  • Travel speed (C-track)
    max. 3 m/s
  • Bend radius (moving)
    12× outer Ø
  • Temperature range (mobile)
    -20...+50 °C
  • Bend radius (fixed)
    7.5× outer Ø
  • Temperature range (fixed)
    -25...+70 °C
  • Nominal voltage
    30 V AC
  • Test voltage
    1.5 kV
  • Shield (Type)
    Copper braid
  • Color (jacket)
    violet
  • Jacket Color
    violet
  • Outer-Ø (jacket)
    7.8 mm ±5%
  • Material (jacket)
    PVC
  • optical shield cover
    min. 70%
  • Shield
    yes
  • Color/numbering of wires
    rd, gn
  • Wire-Ø incl. isolation
    2.55 mm ±5%
  • Single wire Ø (core)
    0.13 mm
  • AWG
    similar to AWG 24
  • Construction (core)
    19× 0.13 mm
  • Diameter (core)
    1× 2× 0.25 mm²
  • Resistor (core)
    max. 68 Ω/km (20 °C)
  • Material (wire isolation)
    PE
  • Material (wire)
    Cu wire, bare
  • Cable weight [g/m]
    75,9 g
  • Cable identification
    850
  • C-track properties
    2 Mio.
  • No./diameter of wires
    1× 2× 0.25 mm²
  • Temperature range
    -25...+85 °C, depending on cable quality
  • Wire isolation
    PE (rd, gn)
  • Outer Ø
    7.8 mm ±5%
  • Mounting method
    inserted, tightened
  • Pollution Degree
    3
  • Standards
    DIN EN 61076-2-101 (M12)
  • Compression gland
    M12 (SW13)
  • Rated surge voltage
    1.5 kV
  • Form
    44001
  • Operating current per contact
    max. 4 A
  • Locking material
    Zinc die casting, matte nickel plated
  • suitable for corrugated tube (internal Ø)
    without
  • Operating voltage (only UL listed)
    max. 30 V AC/DC
  • Material
    PUR
  • Material group
    IEC 60664-1, category I
  • Coding
    B-coded
  • Locking of ports
    Screw thread (M12×1 mm) recommended torque 0.6 Nm, self-securing
  • Protection
    IP65, IP66K, IP67 inserted and tightened (EN 60529)
  • Operating voltage
    max. 60 V AC/DC

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


About the product

7000-44001-8500100 Murrelektronik - M12 male 0°/M12 female 0° shielded B-cod.Profibus, PVC 1x2xAWG24 shielded vt UL/CSA 1m



7000-44001-8500100 Related Documents

Manufacturer warranty

7000-44001-8500100 Murr Elektronik

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 7000-44001-8500100 with other products

Weight

Series

Product article number of manufacturer

No. of bending cycles (C-track)

Cable length

Acceleration (C-track)

Travel speed (C-track)

Bend radius (moving)

Temperature range (mobile)

Bend radius (fixed)

Temperature range (fixed)

Nominal voltage

Test voltage

Shield (Type)

Color (jacket)

Jacket Color

Outer-Ø (jacket)

Material (jacket)

optical shield cover

Shield

Color/numbering of wires

Wire-Ø incl. isolation

Single wire Ø (core)

AWG

Construction (core)

Diameter (core)

Resistor (core)

Material (wire isolation)

Material (wire)

Cable weight [g/m]

Cable identification

C-track properties

No./diameter of wires

Temperature range

Wire isolation

Outer Ø

Mounting method

Pollution Degree

Standards

Compression gland

Rated surge voltage

Form

Operating current per contact

Locking material

suitable for corrugated tube (internal Ø)

Operating voltage (only UL listed)

Material

Material group

Coding

Locking of ports

Protection

Operating voltage

Cable length

Torsion stress

Product article number of manufacturer

Travel speed (C-track)

Acceleration (C-track)

No. of bending cycles (C-track)

Bend radius (moving)

Temperature range (mobile)

Bend radius (fixed)

AWG

Test voltage

Outer-Ø (jacket)

Temperature range (fixed)

chemical resistance

Nominal voltage

Jacket Color

Color (jacket)

Shore hardness (jacket)

Material (jacket)

Wire-Ø incl. isolation

Shield

Color/numbering of wires

Material property (wire isolation)

Construction (core)

C-track properties

Resistor (core)

Material (wire isolation)

Single wire Ø (core)

Cable weight [g/m]

Diameter (core)

Outer Ø

Approval (cable)

Material (wire)

Cable identification

suitable for corrugated tube (internal Ø)

Temperature range

Compression gland

Standards

No./diameter of wires

Wire isolation

Mounting method

Pollution Degree

Locking material

Protection

Locking of ports

Coding

Operating current per contact

Material

Material group

Operating voltage

Form

Rated surge voltage

Cable length

Product article number of manufacturer

Torsion stress

Torsion speed

No. of torsion cycles

Acceleration (C-track)

Bend radius (fixed)

Travel speed (C-track)

No. of bending cycles (C-track)

Temperature range (fixed)

Bend radius (moving)

Temperature range (mobile)

Test voltage

Current load capacity

Nominal voltage

Outer-Ø (jacket)

thermal resistance

chemical resistance

Color (jacket)

Shore hardness (jacket)

Material property (jacket)

Jacket Color

Material (jacket)

Stranding combination

Shield

Material property (wire isolation)

Material (wire isolation)

AWG

Wire-Ø incl. isolation

Shore hardness (wire isolation)

Color/numbering of wires

Diameter (core)

Construction (core)

Single wire Ø (core)

Resistor (core)

Approval (cable)

Material (wire)

Cable Type

Outer Ø

Cable weight [g/m]

C-track properties

Cable identification

Wire isolation

No./diameter of wires

Temperature range

suitable for corrugated tube (internal Ø)

Compression gland

Mounting method

Protection

Pollution Degree

Locking material

Locking of ports

Coding

Operating voltage

Material group

Rated surge voltage

No. of poles

Operating current per contact

Operating voltage (only UL listed)

Form

Selected product

7000-44001-8500100
0 in stock
7000-44001-8500100
Murr Elektronik

7000-44001-8500100 Murrelektronik - M12 male 0°/M12 female 0° shielded B-cod.Profibus, PVC 1x2xAWG24...

Weight83 g

SeriesConnector Systems

Product article number of manufacturer7000-44001-8500100

No. of bending cycles (C-track)max. 2 Mio. (25 °C)

Cable length1 m

Acceleration (C-track)max. 5 m/s²

Travel speed (C-track)max. 3 m/s

Bend radius (moving)12× outer Ø

Temperature range (mobile)-20...+50 °C

Bend radius (fixed)7.5× outer Ø

Temperature range (fixed)-25...+70 °C

Nominal voltage30 V AC

Test voltage1.5 kV

Shield (Type)Copper braid

Color (jacket)violet

Jacket Colorviolet

Outer-Ø (jacket)7.8 mm ±5%

Material (jacket)PVC

optical shield covermin. 70%

Shieldyes

Color/numbering of wiresrd, gn

Wire-Ø incl. isolation2.55 mm ±5%

Single wire Ø (core)0.13 mm

AWGsimilar to AWG 24

Construction (core)19× 0.13 mm

Diameter (core)1× 2× 0.25 mm²

Resistor (core)max. 68 Ω/km (20 °C)

Material (wire isolation)PE

Material (wire)Cu wire, bare

Cable weight [g/m]75,9 g

Cable identification850

C-track properties2 Mio.

No./diameter of wires1× 2× 0.25 mm²

Temperature range-25...+85 °C, depending on cable quality

Wire isolationPE (rd, gn)

Outer Ø7.8 mm ±5%

Mounting methodinserted, tightened

Pollution Degree3

StandardsDIN EN 61076-2-101 (M12)

Compression glandM12 (SW13)

Rated surge voltage1.5 kV

Form44001

Operating current per contactmax. 4 A

Locking materialZinc die casting, matte nickel plated

suitable for corrugated tube (internal Ø)without

Operating voltage (only UL listed)max. 30 V AC/DC

MaterialPUR

Material groupIEC 60664-1, category I

CodingB-coded

Locking of portsScrew thread (M12×1 mm) recommended torque 0.6 Nm, self-securing

ProtectionIP65, IP66K, IP67 inserted and tightened (EN 60529)

Operating voltagemax. 60 V AC/DC

Cable length-

Torsion stress-

Product article number of manufacturer-

Travel speed (C-track)-

Acceleration (C-track)-

No. of bending cycles (C-track)-

Bend radius (moving)-

Temperature range (mobile)-

Bend radius (fixed)-

AWG-

Test voltage-

Outer-Ø (jacket)-

Temperature range (fixed)-

chemical resistance-

Nominal voltage-

Jacket Color-

Color (jacket)-

Shore hardness (jacket)-

Material (jacket)-

Wire-Ø incl. isolation-

Shield-

Color/numbering of wires-

Material property (wire isolation)-

Construction (core)-

C-track properties-

Resistor (core)-

Material (wire isolation)-

Single wire Ø (core)-

Cable weight [g/m]-

Diameter (core)-

Outer Ø-

Approval (cable)-

Material (wire)-

Cable identification-

suitable for corrugated tube (internal Ø)-

Temperature range-

Compression gland-

Standards-

No./diameter of wires-

Wire isolation-

Mounting method-

Pollution Degree-

Locking material-

Protection-

Locking of ports-

Coding-

Operating current per contact-

Material-

Material group-

Operating voltage-

Form-

Rated surge voltage-

Cable length-

Product article number of manufacturer-

Torsion stress-

Torsion speed-

No. of torsion cycles-

Acceleration (C-track)-

Bend radius (fixed)-

Travel speed (C-track)-

No. of bending cycles (C-track)-

Temperature range (fixed)-

Bend radius (moving)-

Temperature range (mobile)-

Test voltage-

Current load capacity-

Nominal voltage-

Outer-Ø (jacket)-

thermal resistance-

chemical resistance-

Color (jacket)-

Shore hardness (jacket)-

Material property (jacket)-

Jacket Color-

Material (jacket)-

Stranding combination-

Shield-

Material property (wire isolation)-

Material (wire isolation)-

AWG-

Wire-Ø incl. isolation-

Shore hardness (wire isolation)-

Color/numbering of wires-

Diameter (core)-

Construction (core)-

Single wire Ø (core)-

Resistor (core)-

Approval (cable)-

Material (wire)-

Cable Type-

Outer Ø-

Cable weight [g/m]-

C-track properties-

Cable identification-

Wire isolation-

No./diameter of wires-

Temperature range-

suitable for corrugated tube (internal Ø)-

Compression gland-

Mounting method-

Protection-

Pollution Degree-

Locking material-

Locking of ports-

Coding-

Operating voltage-

Material group-

Rated surge voltage-

No. of poles-

Operating current per contact-

Operating voltage (only UL listed)-

Form-

7000-19041-7050500
3 in stock
7000-19041-7050500
Murr Elektronik

7000-19041-7050500 Murrelektronik - M12 FEMALE 0°, PUR 12x0,14 black drag ch AIN 5m

Weight377 g

SeriesConnector Systems

Product article number of manufacturer-

No. of bending cycles (C-track)-

Cable length-

Acceleration (C-track)-

Travel speed (C-track)-

Bend radius (moving)-

Temperature range (mobile)-

Bend radius (fixed)-

Temperature range (fixed)-

Nominal voltage-

Test voltage-

Shield (Type)-

Color (jacket)-

Jacket Color-

Outer-Ø (jacket)-

Material (jacket)-

optical shield cover-

Shield-

Color/numbering of wires-

Wire-Ø incl. isolation-

Single wire Ø (core)-

AWG-

Construction (core)-

Diameter (core)-

Resistor (core)-

Material (wire isolation)-

Material (wire)-

Cable weight [g/m]-

Cable identification-

C-track properties-

No./diameter of wires-

Temperature range-

Wire isolation-

Outer Ø-

Mounting method-

Pollution Degree-

Standards-

Compression gland-

Rated surge voltage-

Form-

Operating current per contact-

Locking material-

suitable for corrugated tube (internal Ø)-

Operating voltage (only UL listed)-

Material-

Material group-

Coding-

Locking of ports-

Protection-

Operating voltage-

Cable length5 m

Torsion stress±180°/m

Product article number of manufacturer7000-19041-7050500

Travel speed (C-track)max. 3.3 m/s

Acceleration (C-track)max. 5 m/s²

No. of bending cycles (C-track)max. 2 Mio. (25 °C)

Bend radius (moving)10× outer Ø

Temperature range (mobile)-25...+85 °C

Bend radius (fixed)7.5× outer Ø

AWGsimilar to AWG 26

Test voltage1500 V AC

Outer-Ø (jacket)6.0 mm ±5%

Temperature range (fixed)-40...+85 °C

chemical resistancegood resistance to oil, gasoline and chemicals (VDE 0472 Teil 803 Test B)

Nominal voltage300 V AC

Jacket Colorblack

Color (jacket)black

Shore hardness (jacket)92 ±5 A

Material (jacket)PUR

Wire-Ø incl. isolation1.0 mm ±5%

Shieldno

Color/numbering of wiresbr, rd, gr, bk, ye, pk, gn, wh, bl, rdbl, grpk, vi

Material property (wire isolation)CFC-, halogen-, cadmium-, silicone- and lead-free

Construction (core)18× 0.1 mm (multi-strand wire class 6)

C-track properties2 Mio.

Resistor (core)max. 138 Ω/km (20 °C)

Material (wire isolation)PP

Single wire Ø (core)0.1 mm

Cable weight [g/m]45,1 g

Diameter (core)12× 0.14 mm²

Outer Ø6.0 mm ±5%

Approval (cable)UL (AWM-Style 20233/10493), CSA; CE conform

Material (wire)Cu wire, bare

Cable identification705

suitable for corrugated tube (internal Ø)without

Temperature range-25...+85 °C, depending on cable quality

Compression glandM12 (SW13)

StandardsDIN EN 61076-2-101 (M12)

No./diameter of wires12× 0.14 mm²

Wire isolationPP (br, bl, wh, gn, pk, ye, bk, gr, rd, vi, grpk, rdbl)

Mounting methodinserted, tightened

Pollution Degree3

Locking materialZinc die casting, matte nickel plated

ProtectionIP65, IP66K, IP67 inserted and tightened (EN 60529)

Locking of portsScrew thread (M12×1 mm) recommended torque 0.6 Nm, self-securing

CodingA-coded

Operating current per contactmax. 1.5 A

MaterialPUR

Material groupIEC 60664-1, category I

Operating voltagemax. 30 V AC/DC

Form19041

Rated surge voltage0.8 kV

Cable length-

Product article number of manufacturer-

Torsion stress-

Torsion speed-

No. of torsion cycles-

Acceleration (C-track)-

Bend radius (fixed)-

Travel speed (C-track)-

No. of bending cycles (C-track)-

Temperature range (fixed)-

Bend radius (moving)-

Temperature range (mobile)-

Test voltage-

Current load capacity-

Nominal voltage-

Outer-Ø (jacket)-

thermal resistance-

chemical resistance-

Color (jacket)-

Shore hardness (jacket)-

Material property (jacket)-

Jacket Color-

Material (jacket)-

Stranding combination-

Shield-

Material property (wire isolation)-

Material (wire isolation)-

AWG-

Wire-Ø incl. isolation-

Shore hardness (wire isolation)-

Color/numbering of wires-

Diameter (core)-

Construction (core)-

Single wire Ø (core)-

Resistor (core)-

Approval (cable)-

Material (wire)-

Cable Type-

Outer Ø-

Cable weight [g/m]-

C-track properties-

Cable identification-

Wire isolation-

No./diameter of wires-

Temperature range-

suitable for corrugated tube (internal Ø)-

Compression gland-

Mounting method-

Protection-

Pollution Degree-

Locking material-

Locking of ports-

Coding-

Operating voltage-

Material group-

Rated surge voltage-

No. of poles-

Operating current per contact-

Operating voltage (only UL listed)-

Form-

7030-40041-0350200
3 in stock
7030-40041-0350200
Murr Elektronik

7030-40041-0350200 Murrelektronik - M12 male 0° / M12 female 0° AIDA, PUR 5x0.34 ye UL/CSA+drag chai...

Weight100 g

SeriesConnector Systems

Product article number of manufacturer-

No. of bending cycles (C-track)-

Cable length-

Acceleration (C-track)-

Travel speed (C-track)-

Bend radius (moving)-

Temperature range (mobile)-

Bend radius (fixed)-

Temperature range (fixed)-

Nominal voltage-

Test voltage-

Shield (Type)-

Color (jacket)-

Jacket Color-

Outer-Ø (jacket)-

Material (jacket)-

optical shield cover-

Shield-

Color/numbering of wires-

Wire-Ø incl. isolation-

Single wire Ø (core)-

AWG-

Construction (core)-

Diameter (core)-

Resistor (core)-

Material (wire isolation)-

Material (wire)-

Cable weight [g/m]-

Cable identification-

C-track properties-

No./diameter of wires-

Temperature range-

Wire isolation-

Outer Ø-

Mounting method-

Pollution Degree-

Standards-

Compression gland-

Rated surge voltage-

Form-

Operating current per contact-

Locking material-

suitable for corrugated tube (internal Ø)-

Operating voltage (only UL listed)-

Material-

Material group-

Coding-

Locking of ports-

Protection-

Operating voltage-

Cable length-

Torsion stress-

Product article number of manufacturer-

Travel speed (C-track)-

Acceleration (C-track)-

No. of bending cycles (C-track)-

Bend radius (moving)-

Temperature range (mobile)-

Bend radius (fixed)-

AWG-

Test voltage-

Outer-Ø (jacket)-

Temperature range (fixed)-

chemical resistance-

Nominal voltage-

Jacket Color-

Color (jacket)-

Shore hardness (jacket)-

Material (jacket)-

Wire-Ø incl. isolation-

Shield-

Color/numbering of wires-

Material property (wire isolation)-

Construction (core)-

C-track properties-

Resistor (core)-

Material (wire isolation)-

Single wire Ø (core)-

Cable weight [g/m]-

Diameter (core)-

Outer Ø-

Approval (cable)-

Material (wire)-

Cable identification-

suitable for corrugated tube (internal Ø)-

Temperature range-

Compression gland-

Standards-

No./diameter of wires-

Wire isolation-

Mounting method-

Pollution Degree-

Locking material-

Protection-

Locking of ports-

Coding-

Operating current per contact-

Material-

Material group-

Operating voltage-

Form-

Rated surge voltage-

Cable length2 m

Product article number of manufacturer7030-40041-0350200

Torsion stress±180°/m

Torsion speed35 cycles/min

No. of torsion cyclesmax. 2 Mio. (25 °C)

Acceleration (C-track)max. 10 m/s²

Bend radius (fixed)5× outer Ø

Travel speed (C-track)max. 3 m/s

No. of bending cycles (C-track)max. 10 Mio. (25 °C)

Temperature range (fixed)-40...+80 °C

Bend radius (moving)10× outer Ø

Temperature range (mobile)-25...+80 °C

Test voltage2500 V AC

Current load capacityto DIN VDE 0298-4

Nominal voltage300 V AC

Outer-Ø (jacket)4.8 mm ±5%

thermal resistanceflame retardand UL 1581 Section 1090 (H), CSA FT2 / IEC 60332-2-2

chemical resistancegood resistance to oil, gasoline and chemicals (EN 60811-404)

Color (jacket)yellow

Shore hardness (jacket)90 ±5 A

Material property (jacket)CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistant

Jacket Coloryellow

Material (jacket)PUR

Stranding combination5 wires twisted around central filler

Shieldno

Material property (wire isolation)CFC-, halogen-, cadmium-, silicone- and lead-free

Material (wire isolation)PP

AWGsimilar to AWG 22

Wire-Ø incl. isolation1.25 mm ±5%

Shore hardness (wire isolation)70 ±5 D

Color/numbering of wiresbr, bk, bl, wh, gnye longitudinally striped

Diameter (core)5× 0.34 mm²

Construction (core)42× 0.1 mm (multi-strand wire class 6)

Single wire Ø (core)0.1 mm

Resistor (core)max. 57 Ω/km (20 °C)

Approval (cable)cURus (AWM-Style 20549/10493); CE conform

Material (wire)Cu wire, bare

Cable Type3 (PUR)

Outer Ø4.8 mm ±5%

Cable weight [g/m]41,8 g

C-track properties10 Mio.

Cable identification035

Wire isolationPP (br, wh, bl, bk, gnye)

No./diameter of wires5× 0.34 mm²

Temperature range-25...+85 °C, depending on cable quality

suitable for corrugated tube (internal Ø)10 mm

Compression glandM12 (SW13)

Mounting methodinserted, tightened

ProtectionIP65, IP66K, IP67 inserted and tightened (EN 60529)

Pollution Degree3

Locking materialZinc die casting, matte nickel plated

Locking of portsScrew thread (M12×1 mm) recommended torque 0.6 Nm, self-securing

CodingA-coded

Operating voltagemax. 125 V AC/DC

Material groupIEC 60664-1, category I

Rated surge voltage1.5 kV

No. of poles5

Operating current per contactmax. 4 A

Operating voltage (only UL listed)max. 30 V AC/DC

Form40041

About the manufacturer

Murr Elektronik

Murrelektronik is a worldwide frontrunner in creating, producing, and distributing automation solutions. Our product offerings are categorized into four main lines: Power Supplies and Control, Interfaces, Cables/Connectors, and IO Systems.

Recently viewed products

Relevant products

FAQ

Out if stock but available for backorder.

7000-44001-8500100 Murrelektronik - M12 male 0°/M12 female 0° shielded B-cod.Profibus, PVC 1x2xAWG24 shielded vt UL/CSA 1m

Similar products from: Cable Assemblies

What can I help you find today?

Recommended parts