7000-14051-8500500 Murrelektronik - M12 male 0° shielded B-cod. with cable, Profibus, PVC 1x2xAWG24 shielded vt UL/CSA 5m

Product Details

  • Weight
    286 g
  • Series
    Connector Systems
  • Acceleration (C-track)
    max. 5 m/s²
  • Cable length
    5 m
  • Temperature range (fixed)
    -25...+70 °C
  • Product article number of manufacturer
    7000-14051-8500500
  • Travel speed (C-track)
    max. 3 m/s
  • No. of bending cycles (C-track)
    max. 2 Mio. (25 °C)
  • Bend radius (fixed)
    7.5× outer Ø
  • Bend radius (moving)
    12× outer Ø
  • Temperature range (mobile)
    -20...+50 °C
  • Nominal voltage
    30 V AC
  • Jacket Color
    violet
  • Test voltage
    1.5 kV
  • Color (jacket)
    violet
  • AWG
    similar to AWG 24
  • Material (jacket)
    PVC
  • Shield (Type)
    Copper braid
  • Shield
    yes
  • optical shield cover
    min. 70%
  • Outer-Ø (jacket)
    7.8 mm ±5%
  • Material (wire isolation)
    PE
  • Color/numbering of wires
    rd, gn
  • Wire-Ø incl. isolation
    2.55 mm ±5%
  • Single wire Ø (core)
    0.13 mm
  • Construction (core)
    19× 0.13 mm
  • Diameter (core)
    1× 2× 0.25 mm²
  • Cable identification
    850
  • Material (wire)
    Cu wire, bare
  • Outer Ø
    7.8 mm ±5%
  • Cable weight [g/m]
    75,9 g
  • Resistor (core)
    max. 68 Ω/km (20 °C)
  • Wire isolation
    PE (rd, gn)
  • C-track properties
    2 Mio.
  • No./diameter of wires
    1× 2× 0.25 mm²
  • Mounting method
    inserted, tightened
  • Temperature range
    -25...+85 °C, depending on cable quality
  • Pollution Degree
    3
  • Standards
    DIN EN 61076-2-101 (M12)
  • Stripping length (jacket)
    20 mm
  • Locking material
    Zinc die casting, matte nickel plated
  • Compression gland
    M12 (SW13)
  • Material
    PUR
  • suitable for corrugated tube (internal Ø)
    without
  • Coding
    B-coded
  • Operating voltage (only UL listed)
    max. 30 V AC/DC
  • Operating current per contact
    max. 4 A
  • Material group
    IEC 60664-1, category I
  • Operating voltage
    max. 60 V AC/DC
  • Locking of ports
    Screw thread (M12×1 mm) recommended torque 0.6 Nm, self-securing
  • Rated surge voltage
    1.5 kV
  • Protection
    IP65, IP66K, IP67 inserted and tightened (EN 60529)
  • Form
    14051

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


About the product

7000-14051-8500500 Murrelektronik - M12 male 0° shielded B-cod. with cable, Profibus, PVC 1x2xAWG24 shielded vt UL/CSA 5m



7000-14051-8500500 Related Documents

Manufacturer warranty

7000-14051-8500500 Murr Elektronik

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 7000-14051-8500500 with other products

Weight

Series

Acceleration (C-track)

Cable length

Temperature range (fixed)

Product article number of manufacturer

Travel speed (C-track)

No. of bending cycles (C-track)

Bend radius (fixed)

Bend radius (moving)

Temperature range (mobile)

Nominal voltage

Jacket Color

Test voltage

Color (jacket)

AWG

Material (jacket)

Shield (Type)

Shield

optical shield cover

Outer-Ø (jacket)

Material (wire isolation)

Color/numbering of wires

Wire-Ø incl. isolation

Single wire Ø (core)

Construction (core)

Diameter (core)

Cable identification

Material (wire)

Outer Ø

Cable weight [g/m]

Resistor (core)

Wire isolation

C-track properties

No./diameter of wires

Mounting method

Temperature range

Pollution Degree

Standards

Stripping length (jacket)

Locking material

Compression gland

Material

suitable for corrugated tube (internal Ø)

Coding

Operating voltage (only UL listed)

Operating current per contact

Material group

Operating voltage

Locking of ports

Rated surge voltage

Protection

Form

Cable length

Torsion stress

Product article number of manufacturer

Travel speed (C-track)

Acceleration (C-track)

No. of bending cycles (C-track)

Bend radius (moving)

Temperature range (mobile)

Bend radius (fixed)

AWG

Test voltage

Outer-Ø (jacket)

Temperature range (fixed)

chemical resistance

Nominal voltage

Jacket Color

Color (jacket)

Shore hardness (jacket)

Material (jacket)

Wire-Ø incl. isolation

Shield

Color/numbering of wires

Material property (wire isolation)

Construction (core)

C-track properties

Resistor (core)

Material (wire isolation)

Single wire Ø (core)

Cable weight [g/m]

Diameter (core)

Outer Ø

Approval (cable)

Material (wire)

Cable identification

suitable for corrugated tube (internal Ø)

Temperature range

Compression gland

Standards

No./diameter of wires

Wire isolation

Mounting method

Pollution Degree

Locking material

Protection

Locking of ports

Coding

Operating current per contact

Material

Material group

Operating voltage

Form

Rated surge voltage

Torsion speed

Temperature range (mobile)

Cable length

Acceleration (C-track)

Product article number of manufacturer

Bend radius (fixed)

No. of torsion cycles

Torsion stress

No. of bending cycles (C-track)

Bend radius (moving)

Temperature range (fixed)

Current load capacity

Travel speed (C-track)

Test voltage

Nominal voltage

Shield

thermal resistance

chemical resistance

Jacket Color

Material property (wire isolation)

Color (jacket)

Stranding combination

Shore hardness (wire isolation)

Shore hardness (jacket)

Color/numbering of wires

Material property (jacket)

AWG

Outer-Ø (jacket)

Wire-Ø incl. isolation

Construction (core)

Single wire Ø (core)

Material (jacket)

Material (wire isolation)

Wire isolation

Approval (cable)

Diameter (core)

Cable weight [g/m]

Temperature range

Cable Type

Resistor (core)

Material (wire)

Cable identification

Outer Ø

C-track properties

No./diameter of wires

Mounting method

Pollution Degree

Protection

Material group

Operating voltage

Locking material

Compression gland

suitable for corrugated tube (internal Ø)

Operating voltage (only UL listed)

No. of poles

Locking of ports

Rated surge voltage

Coding

Operating current per contact

Form

Selected product

7000-14051-8500500
0 in stock
7000-14051-8500500
Murr Elektronik

7000-14051-8500500 Murrelektronik - M12 male 0° shielded B-cod. with cable, Profibus, PVC 1x2xAWG24 ...

Weight286 g

SeriesConnector Systems

Acceleration (C-track)max. 5 m/s²

Cable length5 m

Temperature range (fixed)-25...+70 °C

Product article number of manufacturer7000-14051-8500500

Travel speed (C-track)max. 3 m/s

No. of bending cycles (C-track)max. 2 Mio. (25 °C)

Bend radius (fixed)7.5× outer Ø

Bend radius (moving)12× outer Ø

Temperature range (mobile)-20...+50 °C

Nominal voltage30 V AC

Jacket Colorviolet

Test voltage1.5 kV

Color (jacket)violet

AWGsimilar to AWG 24

Material (jacket)PVC

Shield (Type)Copper braid

Shieldyes

optical shield covermin. 70%

Outer-Ø (jacket)7.8 mm ±5%

Material (wire isolation)PE

Color/numbering of wiresrd, gn

Wire-Ø incl. isolation2.55 mm ±5%

Single wire Ø (core)0.13 mm

Construction (core)19× 0.13 mm

Diameter (core)1× 2× 0.25 mm²

Cable identification850

Material (wire)Cu wire, bare

Outer Ø7.8 mm ±5%

Cable weight [g/m]75,9 g

Resistor (core)max. 68 Ω/km (20 °C)

Wire isolationPE (rd, gn)

C-track properties2 Mio.

No./diameter of wires1× 2× 0.25 mm²

Mounting methodinserted, tightened

Temperature range-25...+85 °C, depending on cable quality

Pollution Degree3

StandardsDIN EN 61076-2-101 (M12)

Stripping length (jacket)20 mm

Locking materialZinc die casting, matte nickel plated

Compression glandM12 (SW13)

MaterialPUR

suitable for corrugated tube (internal Ø)without

CodingB-coded

Operating voltage (only UL listed)max. 30 V AC/DC

Operating current per contactmax. 4 A

Material groupIEC 60664-1, category I

Operating voltagemax. 60 V AC/DC

Locking of portsScrew thread (M12×1 mm) recommended torque 0.6 Nm, self-securing

Rated surge voltage1.5 kV

ProtectionIP65, IP66K, IP67 inserted and tightened (EN 60529)

Form14051

Cable length-

Torsion stress-

Product article number of manufacturer-

Travel speed (C-track)-

Acceleration (C-track)-

No. of bending cycles (C-track)-

Bend radius (moving)-

Temperature range (mobile)-

Bend radius (fixed)-

AWG-

Test voltage-

Outer-Ø (jacket)-

Temperature range (fixed)-

chemical resistance-

Nominal voltage-

Jacket Color-

Color (jacket)-

Shore hardness (jacket)-

Material (jacket)-

Wire-Ø incl. isolation-

Shield-

Color/numbering of wires-

Material property (wire isolation)-

Construction (core)-

C-track properties-

Resistor (core)-

Material (wire isolation)-

Single wire Ø (core)-

Cable weight [g/m]-

Diameter (core)-

Outer Ø-

Approval (cable)-

Material (wire)-

Cable identification-

suitable for corrugated tube (internal Ø)-

Temperature range-

Compression gland-

Standards-

No./diameter of wires-

Wire isolation-

Mounting method-

Pollution Degree-

Locking material-

Protection-

Locking of ports-

Coding-

Operating current per contact-

Material-

Material group-

Operating voltage-

Form-

Rated surge voltage-

Torsion speed-

Temperature range (mobile)-

Cable length-

Acceleration (C-track)-

Product article number of manufacturer-

Bend radius (fixed)-

No. of torsion cycles-

Torsion stress-

No. of bending cycles (C-track)-

Bend radius (moving)-

Temperature range (fixed)-

Current load capacity-

Travel speed (C-track)-

Test voltage-

Nominal voltage-

Shield-

thermal resistance-

chemical resistance-

Jacket Color-

Material property (wire isolation)-

Color (jacket)-

Stranding combination-

Shore hardness (wire isolation)-

Shore hardness (jacket)-

Color/numbering of wires-

Material property (jacket)-

AWG-

Outer-Ø (jacket)-

Wire-Ø incl. isolation-

Construction (core)-

Single wire Ø (core)-

Material (jacket)-

Material (wire isolation)-

Wire isolation-

Approval (cable)-

Diameter (core)-

Cable weight [g/m]-

Temperature range-

Cable Type-

Resistor (core)-

Material (wire)-

Cable identification-

Outer Ø-

C-track properties-

No./diameter of wires-

Mounting method-

Pollution Degree-

Protection-

Material group-

Operating voltage-

Locking material-

Compression gland-

suitable for corrugated tube (internal Ø)-

Operating voltage (only UL listed)-

No. of poles-

Locking of ports-

Rated surge voltage-

Coding-

Operating current per contact-

Form-

7000-19041-7050500
3 in stock
7000-19041-7050500
Murr Elektronik

7000-19041-7050500 Murrelektronik - M12 FEMALE 0°, PUR 12x0,14 black drag ch AIN 5m

Weight377 g

SeriesConnector Systems

Acceleration (C-track)-

Cable length-

Temperature range (fixed)-

Product article number of manufacturer-

Travel speed (C-track)-

No. of bending cycles (C-track)-

Bend radius (fixed)-

Bend radius (moving)-

Temperature range (mobile)-

Nominal voltage-

Jacket Color-

Test voltage-

Color (jacket)-

AWG-

Material (jacket)-

Shield (Type)-

Shield-

optical shield cover-

Outer-Ø (jacket)-

Material (wire isolation)-

Color/numbering of wires-

Wire-Ø incl. isolation-

Single wire Ø (core)-

Construction (core)-

Diameter (core)-

Cable identification-

Material (wire)-

Outer Ø-

Cable weight [g/m]-

Resistor (core)-

Wire isolation-

C-track properties-

No./diameter of wires-

Mounting method-

Temperature range-

Pollution Degree-

Standards-

Stripping length (jacket)-

Locking material-

Compression gland-

Material-

suitable for corrugated tube (internal Ø)-

Coding-

Operating voltage (only UL listed)-

Operating current per contact-

Material group-

Operating voltage-

Locking of ports-

Rated surge voltage-

Protection-

Form-

Cable length5 m

Torsion stress±180°/m

Product article number of manufacturer7000-19041-7050500

Travel speed (C-track)max. 3.3 m/s

Acceleration (C-track)max. 5 m/s²

No. of bending cycles (C-track)max. 2 Mio. (25 °C)

Bend radius (moving)10× outer Ø

Temperature range (mobile)-25...+85 °C

Bend radius (fixed)7.5× outer Ø

AWGsimilar to AWG 26

Test voltage1500 V AC

Outer-Ø (jacket)6.0 mm ±5%

Temperature range (fixed)-40...+85 °C

chemical resistancegood resistance to oil, gasoline and chemicals (VDE 0472 Teil 803 Test B)

Nominal voltage300 V AC

Jacket Colorblack

Color (jacket)black

Shore hardness (jacket)92 ±5 A

Material (jacket)PUR

Wire-Ø incl. isolation1.0 mm ±5%

Shieldno

Color/numbering of wiresbr, rd, gr, bk, ye, pk, gn, wh, bl, rdbl, grpk, vi

Material property (wire isolation)CFC-, halogen-, cadmium-, silicone- and lead-free

Construction (core)18× 0.1 mm (multi-strand wire class 6)

C-track properties2 Mio.

Resistor (core)max. 138 Ω/km (20 °C)

Material (wire isolation)PP

Single wire Ø (core)0.1 mm

Cable weight [g/m]45,1 g

Diameter (core)12× 0.14 mm²

Outer Ø6.0 mm ±5%

Approval (cable)UL (AWM-Style 20233/10493), CSA; CE conform

Material (wire)Cu wire, bare

Cable identification705

suitable for corrugated tube (internal Ø)without

Temperature range-25...+85 °C, depending on cable quality

Compression glandM12 (SW13)

StandardsDIN EN 61076-2-101 (M12)

No./diameter of wires12× 0.14 mm²

Wire isolationPP (br, bl, wh, gn, pk, ye, bk, gr, rd, vi, grpk, rdbl)

Mounting methodinserted, tightened

Pollution Degree3

Locking materialZinc die casting, matte nickel plated

ProtectionIP65, IP66K, IP67 inserted and tightened (EN 60529)

Locking of portsScrew thread (M12×1 mm) recommended torque 0.6 Nm, self-securing

CodingA-coded

Operating current per contactmax. 1.5 A

MaterialPUR

Material groupIEC 60664-1, category I

Operating voltagemax. 30 V AC/DC

Form19041

Rated surge voltage0.8 kV

Torsion speed-

Temperature range (mobile)-

Cable length-

Acceleration (C-track)-

Product article number of manufacturer-

Bend radius (fixed)-

No. of torsion cycles-

Torsion stress-

No. of bending cycles (C-track)-

Bend radius (moving)-

Temperature range (fixed)-

Current load capacity-

Travel speed (C-track)-

Test voltage-

Nominal voltage-

Shield-

thermal resistance-

chemical resistance-

Jacket Color-

Material property (wire isolation)-

Color (jacket)-

Stranding combination-

Shore hardness (wire isolation)-

Shore hardness (jacket)-

Color/numbering of wires-

Material property (jacket)-

AWG-

Outer-Ø (jacket)-

Wire-Ø incl. isolation-

Construction (core)-

Single wire Ø (core)-

Material (jacket)-

Material (wire isolation)-

Wire isolation-

Approval (cable)-

Diameter (core)-

Cable weight [g/m]-

Temperature range-

Cable Type-

Resistor (core)-

Material (wire)-

Cable identification-

Outer Ø-

C-track properties-

No./diameter of wires-

Mounting method-

Pollution Degree-

Protection-

Material group-

Operating voltage-

Locking material-

Compression gland-

suitable for corrugated tube (internal Ø)-

Operating voltage (only UL listed)-

No. of poles-

Locking of ports-

Rated surge voltage-

Coding-

Operating current per contact-

Form-

7030-40041-0350500
10 in stock
7030-40041-0350500
Murr Elektronik

7030-40041-0350500 Murrelektronik - M12 male 0° / M12 female 0° AIDA, PUR 5x0.34 ye UL/CSA+drag chai...

Weight219 g

SeriesConnector Systems

Acceleration (C-track)-

Cable length-

Temperature range (fixed)-

Product article number of manufacturer-

Travel speed (C-track)-

No. of bending cycles (C-track)-

Bend radius (fixed)-

Bend radius (moving)-

Temperature range (mobile)-

Nominal voltage-

Jacket Color-

Test voltage-

Color (jacket)-

AWG-

Material (jacket)-

Shield (Type)-

Shield-

optical shield cover-

Outer-Ø (jacket)-

Material (wire isolation)-

Color/numbering of wires-

Wire-Ø incl. isolation-

Single wire Ø (core)-

Construction (core)-

Diameter (core)-

Cable identification-

Material (wire)-

Outer Ø-

Cable weight [g/m]-

Resistor (core)-

Wire isolation-

C-track properties-

No./diameter of wires-

Mounting method-

Temperature range-

Pollution Degree-

Standards-

Stripping length (jacket)-

Locking material-

Compression gland-

Material-

suitable for corrugated tube (internal Ø)-

Coding-

Operating voltage (only UL listed)-

Operating current per contact-

Material group-

Operating voltage-

Locking of ports-

Rated surge voltage-

Protection-

Form-

Cable length-

Torsion stress-

Product article number of manufacturer-

Travel speed (C-track)-

Acceleration (C-track)-

No. of bending cycles (C-track)-

Bend radius (moving)-

Temperature range (mobile)-

Bend radius (fixed)-

AWG-

Test voltage-

Outer-Ø (jacket)-

Temperature range (fixed)-

chemical resistance-

Nominal voltage-

Jacket Color-

Color (jacket)-

Shore hardness (jacket)-

Material (jacket)-

Wire-Ø incl. isolation-

Shield-

Color/numbering of wires-

Material property (wire isolation)-

Construction (core)-

C-track properties-

Resistor (core)-

Material (wire isolation)-

Single wire Ø (core)-

Cable weight [g/m]-

Diameter (core)-

Outer Ø-

Approval (cable)-

Material (wire)-

Cable identification-

suitable for corrugated tube (internal Ø)-

Temperature range-

Compression gland-

Standards-

No./diameter of wires-

Wire isolation-

Mounting method-

Pollution Degree-

Locking material-

Protection-

Locking of ports-

Coding-

Operating current per contact-

Material-

Material group-

Operating voltage-

Form-

Rated surge voltage-

Torsion speed35 cycles/min

Temperature range (mobile)-25...+80 °C

Cable length5 m

Acceleration (C-track)max. 10 m/s²

Product article number of manufacturer7030-40041-0350500

Bend radius (fixed)5× outer Ø

No. of torsion cyclesmax. 2 Mio. (25 °C)

Torsion stress±180°/m

No. of bending cycles (C-track)max. 10 Mio. (25 °C)

Bend radius (moving)10× outer Ø

Temperature range (fixed)-40...+80 °C

Current load capacityto DIN VDE 0298-4

Travel speed (C-track)max. 3 m/s

Test voltage2500 V AC

Nominal voltage300 V AC

Shieldno

thermal resistanceflame retardand UL 1581 Section 1090 (H), CSA FT2 / IEC 60332-2-2

chemical resistancegood resistance to oil, gasoline and chemicals (EN 60811-404)

Jacket Coloryellow

Material property (wire isolation)CFC-, halogen-, cadmium-, silicone- and lead-free

Color (jacket)yellow

Stranding combination5 wires twisted around central filler

Shore hardness (wire isolation)70 ±5 D

Shore hardness (jacket)90 ±5 A

Color/numbering of wiresbr, bk, bl, wh, gnye longitudinally striped

Material property (jacket)CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistant

AWGsimilar to AWG 22

Outer-Ø (jacket)4.8 mm ±5%

Wire-Ø incl. isolation1.25 mm ±5%

Construction (core)42× 0.1 mm (multi-strand wire class 6)

Single wire Ø (core)0.1 mm

Material (jacket)PUR

Material (wire isolation)PP

Wire isolationPP (br, wh, bl, bk, gnye)

Approval (cable)cURus (AWM-Style 20549/10493); CE conform

Diameter (core)5× 0.34 mm²

Cable weight [g/m]41,8 g

Temperature range-25...+85 °C, depending on cable quality

Cable Type3 (PUR)

Resistor (core)max. 57 Ω/km (20 °C)

Material (wire)Cu wire, bare

Cable identification035

Outer Ø4.8 mm ±5%

C-track properties10 Mio.

No./diameter of wires5× 0.34 mm²

Mounting methodinserted, tightened

Pollution Degree3

ProtectionIP65, IP66K, IP67 inserted and tightened (EN 60529)

Material groupIEC 60664-1, category I

Operating voltagemax. 125 V AC/DC

Locking materialZinc die casting, matte nickel plated

Compression glandM12 (SW13)

suitable for corrugated tube (internal Ø)10 mm

Operating voltage (only UL listed)max. 30 V AC/DC

No. of poles5

Locking of portsScrew thread (M12×1 mm) recommended torque 0.6 Nm, self-securing

Rated surge voltage1.5 kV

CodingA-coded

Operating current per contactmax. 4 A

Form40041

About the manufacturer

Murr Elektronik

Murrelektronik is a worldwide frontrunner in creating, producing, and distributing automation solutions. Our product offerings are categorized into four main lines: Power Supplies and Control, Interfaces, Cables/Connectors, and IO Systems.

Recently viewed products

Relevant products

FAQ

Out if stock but available for backorder.

7000-14051-8500500 Murrelektronik - M12 male 0° shielded B-cod. with cable, Profibus, PVC 1x2xAWG24 shielded vt UL/CSA 5m

Similar products from: Cable Assemblies

What can I help you find today?

Recommended parts