165914 Euchner Safety Proximity Sensors

165914 on MQ Automation
Euchner
  • 165914
  • 165914
  • 165914

Part#:165914

Alt. Part#:CES-I-BR-CC-FLX-C07-SA-165914

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

9 in stock

Mar 14, 2025

Product description

165914 Euchner - Non-contact safety switches CES-I-BR-CC-FLX-C07, with FlexFunction, suitable for actuators with same coding

Product Details

  • Weight
    0.13448182 lb
  • Series
    CES-I-BR
  • Product Class
    Safety System
  • Switching hysteresis
    min.1 mm
  • Assured operating distance Sao
    min.10 mm
  • Mission time
    20 y
  • Assured release distance Sar
    max.17 mm
  • Performance Level
    PL e
  • Operating distance
    13 mm
  • Category
    4
  • PFHD
    6 x 10E⁻10
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Additional feature
    Caps included
  • Repeat accuracy R
    ≤ 10
  • Discrepancy time
    max.10 ms
  • Off-state current Ir
    max.0,25 mA
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Test pulses
    0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Test-pulse interval
    ca 100 ms
  • Type of output
    p-switching, short circuit-proof
  • Output voltage
    UB-1,5 ... UB V DC
  • Switching current
    1 ... 50 mA
  • Risk time according to EN 60947-5-3
    max.160 ms
  • Safety class
    III
  • Turn-on time
    max.150 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Current consumption
    40 mA
  • Rated insulation voltage Ui
    300 V
  • Rated conditional short-circuit current
    100 A
  • Fusing
    0,25 ... 8 A
  • Operating voltage DC
    24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
  • Extension of risk time according to EN 60947-5-3 per device
    max.12 ms
  • Connection
    M12 plug connector, 8-pin
  • Ready delay
    5 s
  • Switching frequency
    max.1 Hz
  • Tightening torque
    max.0,8 Nm
  • Installation orientation
    Any
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Mounting method
    Surface mounting on metal
  • Ambient temperature
    -25 ... +60 °C
  • Degree of protection
    IP65/IP67/IP69/IP69K
  • Housing material
    Plastic, PBT-PC-GF30
  • Dimensions
    40 x 26.5 x 18
  • Weight
    0,03 kg
  • Mounting distance
    min.50 mm
  • Operating altitude
    max.4 000 m

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 165914 on MQ Automation is $283.11. Order now.


About the product

Safety switch with integrated evaluation electronics;Suitable for actuator with same coding;Several devices can be connected in series, max. 20;Switch chains up to 200 m long;2 safety outputs (semiconductor outputs);Short circuit monitoring;Diagnostic information via BR IO-Link Gateway;Category 4 / PL e according to EN ISO 13849-1;Three active faces;Plug connector M12, 8-pin (aligned);The safety switch can be used only in conjunction with actuators designated for this purpose.


This item can ship in 3-5 days!

Manufacturer warranty

165914 Euchner

$283.11

Your price can be lower.
Log in or Create account to check your discount

Stock:

9

Select Qty:

$283.11

$283.11 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 165914 with other products

Weight

Series

Product Class

Switching hysteresis

Assured operating distanc...

Mission time

Assured release distance ...

Performance Level

Operating distance

Category

PFHD

For the approval acc. to ...

Additional feature

Repeat accuracy R

Discrepancy time

Off-state current Ir

Utilization category acc....

Test pulses

Test-pulse interval

Type of output

Output voltage

Switching current

Risk time according to EN...

Safety class

Turn-on time

Degree of contamination (...

Rated impulse withstand v...

EMC protection requiremen...

Current consumption

Rated insulation voltage ...

Rated conditional short-c...

Fusing

Operating voltage DC

Extension of risk time ac...

Connection

Ready delay

Switching frequency

Tightening torque

Installation orientation

Shock and vibration resis...

Mounting method

Ambient temperature

Degree of protection

Housing material

Dimensions

Mounting distance

Operating altitude

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Material

Static bending radius

Selected product

165914
9 in stock
165914
Euchner

165914 Euchner - Non-contact safety switches CES-I-BR-CC-FLX-C07, with FlexFunction, suitable for ac...

Weight0.13448182 lb

SeriesCES-I-BR

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.10 mm

Mission time20 y

Assured release distance Sarmax.17 mm

Performance LevelPL e

Operating distance13 mm

Category4

PFHD6 x 10E⁻10

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureCaps included

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulses0,3 ms (Applies for a load...

Test-pulse intervalca 100 ms

Type of outputp-switching, short circuit-p...

Output voltageUB-1,5 ... UB V DC

Switching current1 ... 50 mA

Risk time according to EN 60947-5-3max.160 ms

Safety classIII

Turn-on timemax.150 ms

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Current consumption40 mA

Rated insulation voltage Ui300 V

Rated conditional short-circuit current100 A

Fusing0,25 ... 8 A

Operating voltage DC24 V DC 15% ... 15% Regu...

Extension of risk time according to EN 60947-5-3 per devicemax.12 ms

ConnectionM12 plug connector, 8-pin

Ready delay5 s

Switching frequencymax.1 Hz

Tightening torquemax.0,8 Nm

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting methodSurface mounting on metal

Ambient temperature-25 ... +60 °C

Degree of protectionIP65/IP67/IP69/IP69K

Housing materialPlastic, PBT-PC-GF30

Dimensions40 x 26.5 x 18

Mounting distancemin.50 mm

Operating altitudemax.4 000 m

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Material-

Static bending radius-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Sao6

Mission time20

Assured release distance Sarmax.60 mm

Performance LevelPL e

Operating distance11 mm

Category4

PFHD4.1 x 10⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureRubber support included

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Type of outputSemiconductor output, p-swit...

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Turn-on timemax.400 ms

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Current consumptionmax.35 mA (Without taking i...

Rated insulation voltage Ui300 V

Rated conditional short-circuit current100 A

Fusing0,25 ... 8 A

Operating voltage DC24 V DC 15% ... 15% Regu...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

ConnectionConnection cable PUR, length...

Ready delay10 s

Switching frequencymax.1 Hz

Tightening torquemax.0,8 Nm

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting methodSurface mounting on metal

Ambient temperature-

Degree of protectionIP67

Housing materialPlastic, PBT

Dimensions-

Mounting distancemin.80 mm

Operating altitude-

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

MaterialNBR 80 ±5 Shore

Static bending radius5 x cable diameter

109052
68 in stock
109052
Euchner

109052 Euchner - Non-contact safety switch CES-AR-CR2-..., with flying lead, PUR

Weight1.763696 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.10 mm

Mission time20

Assured release distance Sarmax.40 mm

Performance LevelPL e

Operating distance15 mm

Category4

PFHD1.9 x 10⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Type of outputp-switching, short circuit-p...

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Turn-on timemax.400 ms

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Current consumptionmax.50 mA (Without taking i...

Rated insulation voltage Ui75 V

Rated conditional short-circuit current100 A

Fusing0,25 ... 8 A

Operating voltage DC24 V DC 15% ... 15% Regu...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Connectionconnection cable PUR, length...

Ready delay10 s

Switching frequencymax.1 Hz

Tightening torquemax.1 Nm

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting methodSurface mounting on metal

Ambient temperature-

Degree of protectionIP67, IP69K

Housing materialPlastic, PBT

Dimensions-

Mounting distancemin.120 mm

Operating altitude-

Cable ambient temperature (static)-30 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Material-

Static bending radius5 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 165914?
The price of 165914 on MQ Automation is $283.11. Order now.

Out if stock but available for backorder.

165914 Euchner - Non-contact safety switches CES-I-BR-CC-FLX-C07, with FlexFunction, suitable for actuators with same coding

What can I help you find today?

Recommended parts