Part#:129478

Alt. Part#:CTP-L1-AP-U-HA-AE-SII-129478

Manufacturer:Euchner

Category:Safety Switches

Product Lifecycle:Active

12 in stock

Mar 15, 2025

Product description

129478 Euchner - Transponder-coded safety switch CTP-AP, 2 x M12, with escape release

Product Details

  • Weight
    1.763696 lb
  • Series
    CTP-AP
  • Product Class
    Safety System
  • Mission time
    20 y
  • Category
    4
  • PFHD
    4.1 x 10 ⁻⁹
  • Performance Level
    PL e
  • Repeat accuracy R
    10 %
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Additional feature
    Escape release actuated by pushing
  • Discrepancy time
    max.10 ms In acc. with EN IEC 60947-5-3
  • Output voltage
    0 ... 1 V DC
  • Off-state current Ir
    max.0,25 mA
  • Turn-on time
    max.400 ms
  • Switching current
    1 ... 150 mA
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Safety class
    III
  • Switching load
    24V DC, class 2 (Alternatively see operating instructions)
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Solenoid duty cycle
    100 %
  • Fusing
    0,5 ... 8 A
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Connection rating
    6 W
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Rated insulation voltage Ui
    50 V
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Current consumption
    400 mA
  • Test pulses
    max.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Test-pulse interval
    min.100 ms
  • Locking force Fmax
    3900 N
  • Overtravel
    5 mm
  • Approach speed
    max.20 m/min
  • Guard locking principle
    Closed-circuit current principle
  • Connection
    2 plug connectors M12, 5-pin + pin 5 not used
  • Locking force FZh
    3000 N (Fzh = Fmax/1.3 Depending on the actuator used)
  • Actuating force
    10 N
  • Extraction force
    20 N
  • Retention force
    20 N
  • Ambient temperature
    -20 ... +55 °C
  • Housing material
    Die-cast zinc
  • Degree of protection
    IP67/IP69/IP69K (Screwed tight plug connector/mating component)
  • Switching frequency
    max.0,5 Hz
  • Ready delay
    max.1 s
  • Installation orientation
    Any
  • Mechanical life
    1 x 10⁶
  • Weight
    0,42 kg
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 129478 on MQ Automation is $922.38. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Direct connection to decentralized peripheral systems (e.g. ET200pro);Short circuit monitoring;2 safety outputs (semiconductor outputs);Up to category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Unicode;Door monitoring output;With escape release;Approach directions A, B and C (delivery state)


This item can ship in 3-5 days!

Manufacturer warranty

129478 Euchner

$922.38

Your price can be lower.
Log in or Create account to check your discount

Stock:

12

Select Qty:

$922.38

$922.38 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 129478 with other products

Weight

Series

Product Class

Mission time

Category

PFHD

Performance Level

Repeat accuracy R

For the approval acc. to ...

Additional feature

Discrepancy time

Output voltage

Off-state current Ir

Turn-on time

Switching current

Type of output

Safety class

Switching load

Degree of contamination (...

Solenoid duty cycle

Fusing

EMC protection requiremen...

Connection rating

Utilization category acc....

Rated impulse withstand v...

Rated insulation voltage ...

Operating voltage DC

Solenoid operating voltag...

Current consumption

Test pulses

Test-pulse interval

Locking force Fmax

Overtravel

Approach speed

Guard locking principle

Connection

Locking force FZh

Actuating force

Extraction force

Retention force

Ambient temperature

Housing material

Degree of protection

Switching frequency

Ready delay

Installation orientation

Mechanical life

Shock and vibration resis...

Risk time according to EN...

Extension of risk time ac...

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

129478
12 in stock
129478
Euchner

129478 Euchner - Transponder-coded safety switch CTP-AP, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AP

Product ClassSafety System

Mission time20 y

Category4

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Repeat accuracy R10 %

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0 ... 1 V DC

Off-state current Irmax.0,25 mA

Turn-on timemax.400 ms

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Safety classIII

Switching load24V DC, class 2 (Alternativ...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

Fusing0,5 ... 8 A

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Operating voltage DC24 V DC -15% ... 15% Rev...

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Current consumption400 mA

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Locking force Fmax3900 N

Overtravel5 mm

Approach speedmax.20 m/min

Guard locking principleClosed-circuit current princ...

Connection2 plug connectors M12, 5-pin...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Actuating force10 N

Extraction force20 N

Retention force20 N

Ambient temperature-20 ... +55 °C

Housing materialDie-cast zinc

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Installation orientationAny

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Risk time according to EN 60947-5-3-

Extension of risk time according to EN 60947-5-3 per device-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Category4

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Repeat accuracy R10 %

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0,8xUB ... UB V DC

Off-state current Irmax.0,25 mA

Turn-on timemax.400 ms

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Safety classIII

Switching load24V DC, class 2 (Alternativ...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

Fusing0,25 ... 8 A

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Operating voltage DC24 V DC -15% ... 15% Rev...

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Current consumption40 mA

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Locking force Fmax3900 N

Overtravel5 mm

Approach speedmax.20 m/min

Guard locking principleClosed-circuit current princ...

Connection2 plug connectors M12, 5 and...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Actuating force10 N

Extraction force20 N

Retention force20 N

Ambient temperature-20 ... +55 °C

Housing materialDie-cast zinc

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Switching frequencymax.0,5 Hz

Ready delay8 s

Installation orientationAny

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Risk time according to EN 60947-5-3max.260 ms

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Category4

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Repeat accuracy R10 %

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0 ... 1 V DC

Off-state current Irmax.0,25 mA

Turn-on timemax.400 ms

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Safety classIII

Switching load24V DC, class 2 (Alternativ...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle-

Fusing0,25 ... 8 A

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Operating voltage DC24 V DC -15% ... 15% Rev...

Solenoid operating voltage DC-

Current consumption40 mA

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Locking force Fmax-

Overtravel5 mm

Approach speedmax.20 m/min

Guard locking principle-

Connection2 plug connectors M12, 5-pin

Locking force FZh-

Actuating force10 N

Extraction force20 N

Retention force-

Ambient temperature-20 ... +55 °C

Housing materialFiber glass reinforced therm...

Degree of protectionIP65 (Screwed tight plug co...

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Risk time according to EN 60947-5-3-

Extension of risk time according to EN 60947-5-3 per device-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

FAQ

What is the price of 129478?
The price of 129478 on MQ Automation is $922.38. Order now.

Out if stock but available for backorder.

129478 Euchner - Transponder-coded safety switch CTP-AP, 2 x M12, with escape release

Similar products from: Safety Switches

What can I help you find today?

Recommended parts