Product description

104302 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) without controls or indicators

Product Details

  • Weight
    2.1384814 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Test pulses
    max.1 ms
  • Category
    4
  • Output current
    1 ... 200 mA
  • Product version number
    V4.0.0
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Current consumption
    max.80 mA ((no load on outputs))
  • Test-pulse interval
    min.100 ms
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Transponder coding
    Unicode
  • Discrepancy time
    max.10 ms
  • Safety class
    III
  • Connection cross-section
    0,25 ... 0,75 mm²
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Rated insulation voltage Ui
    30 V
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Locking force FZh
    2000 N
  • Mechanical life
    0,1 x 10⁶
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Switching frequency
    0,25 Hz
  • Degree of protection
    IP65
  • Guard locking principle
    Closed-circuit current principle
  • Weight
    0,75 kg
  • Ambient temperature
    -20 ... 55 °C
  • Installation orientation
    Any
  • Connection
    Cable entries M20x1.5

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 104302 on MQ Automation is $878.46. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);With cable entry;Unicode


This item can ship in 3-5 days!

Manufacturer warranty

104302 Euchner

$878.46

Your price can be lower.
Log in or Create account to check your discount

Stock:

4

Select Qty:

$878.46

$878.46 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 104302 with other products

Weight

Series

Product Class

Mission time

PFHD

Performance Level

Test pulses

Category

Output current

Product version number

Output voltage

Current consumption

Test-pulse interval

Operating voltage DC

Risk time according to EN...

Type of output

Transponder coding

Discrepancy time

Safety class

Connection cross-section

Degree of contamination (...

Rated impulse withstand v...

Rated insulation voltage ...

Utilization category acc....

Locking force FZh

Mechanical life

Housing material

Switching frequency

Degree of protection

Guard locking principle

Ambient temperature

Installation orientation

Connection

For the approval acc. to ...

Additional feature

Repeat accuracy R

Turn-on time

Off-state current Ir

Switching current

Switching load

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Solenoid operating voltag...

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Ready delay

Shock and vibration resis...

Switching hysteresis

Assured operating distanc...

Assured release distance ...

Operating distance

Rated conditional short-c...

Tightening torque

Mounting distance

Cable ambient temperature...

Mounting method

Static bending radius

Cable ambient temperature...

Dynamic bending radius

Selected product

104302
4 in stock
104302
Euchner

104302 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) without controls or in...

Weight2.1384814 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

PFHD3.7 x 10⁻⁹

Performance LevelPL e

Test pulsesmax.1 ms

Category4

Output current1 ... 200 mA

Product version numberV4.0.0

Output voltageUB-2V ... UB V DC (Value at...

Current consumptionmax.80 mA ((no load on outp...

Test-pulse intervalmin.100 ms

Operating voltage DC24 V DC -15% ... 10% ((Re...

Risk time according to EN 60947-5-3max.350 ms

Type of outputSemiconductor outputs, p-swi...

Transponder codingUnicode

Discrepancy timemax.10 ms

Safety classIII

Connection cross-section0,25 ... 0,75 mm²

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui30 V

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Locking force FZh2000 N

Mechanical life0,1 x 10⁶

Housing materialReinforced plastic; die-cast...

Switching frequency0,25 Hz

Degree of protectionIP65

Guard locking principleClosed-circuit current princ...

Ambient temperature-20 ... 55 °C

Installation orientationAny

ConnectionCable entries M20x1.5

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Turn-on time-

Off-state current Ir-

Switching current-

Switching load-

Solenoid duty cycle-

EMC protection requirements-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Ready delay-

Shock and vibration resistance-

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Rated conditional short-circuit current-

Tightening torque-

Mounting distance-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Test pulsesmax.1,0 ms (Applies for a l...

Category4

Output current-

Product version number-

Output voltage0,8xUB ... UB V DC

Current consumption40 mA

Test-pulse intervalmin.140 ms

Operating voltage DC24 V DC -15% ... 15% Rev...

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-p...

Transponder coding-

Discrepancy timemax.10 ms In acc. with EN ...

Safety classIII

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Mechanical life1 x 10⁶

Housing materialDie-cast zinc

Switching frequencymax.0,5 Hz

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Guard locking principleClosed-circuit current princ...

Ambient temperature-20 ... +55 °C

Installation orientationAny

Connection2 plug connectors M12, 5 and...

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Rated conditional short-circuit current-

Tightening torque-

Mounting distance-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Mission time20

PFHD1.9 x 10⁻⁹

Performance LevelPL e

Test pulsesmax.1 ms (Applies for a loa...

Category4

Output current-

Product version number-

Output voltage0,8 x UB ... UB V DC

Current consumptionmax.50 mA (Without taking i...

Test-pulse intervalmin.140 ms

Operating voltage DC24 V DC 15% ... 15% Regu...

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-p...

Transponder coding-

Discrepancy timemax.10 ms

Safety classIII

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Locking force FZh-

Mechanical life-

Housing materialPlastic, PBT

Switching frequencymax.1 Hz

Degree of protectionIP67

Guard locking principle-

Ambient temperature-

Installation orientationAny

ConnectionConnection cable PUR, length...

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R≤ 10

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching currentmax.50 mA

Switching load-

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating-

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Actuating force-

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Ready delay10 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

Rated conditional short-circuit current100 A

Tightening torquemax.1 Nm

Mounting distancemin.120 mm

Cable ambient temperature (dynamic)-25 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 104302?
The price of 104302 on MQ Automation is $878.46. Order now.

Out if stock but available for backorder.

104302 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) without controls or indicators

What can I help you find today?

Recommended parts