100756 Euchner - READ HEAD
Product Details
- Weight 0.090405 lb
- Assured operating distance Sao min.6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
- In compliance with EN ISO 13849-1:2015; EN 50178:1997; EN 60204-1:2006/A1:2009; EN ISO 14119:2013; EN 61000-6-2:2005; EN 61000-6-3:2007/A1:2011; EN 60947-5-3:2013
- Switching voltage according to UL max.24 V DC
- Assured release distance Sar max.17 mm (The assured switch-off distance s_ar corresponds to the reset distance.)
- Switching characteristics In series
- Repeat accuracy R max.10 %
- Tightening torque 0,4 ... 0,5 Nm
- Switching voltage 24 V (DC)
- Rated insulation voltage Ui 26,4 V
- Method of operation Magnetic, reed contact
- Connection 4-pin M8 plug connector
- Switching current 8 ... 500 mA
- Number of NO contacts 3 NO contact
- Rated impulse withstand voltage Uimp 1,5 kV
- Degree of protection IP67
- Mechanical life 100 x 10⁶
- Installation orientation Any, pay attention to marking (During mounting it is to be ensured the marking arrows on actuator and read head are opposite each other.)
- Shock and vibration resistance In acc. with EN 60947-5-3
- Ambient temperature -20 ... 60 °C
- Weight 0,02 kg
- Housing material Fiber glass reinforced PPS
- Design B
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 100756 on MQ Automation is $74.90. Order now.
Manufacturer warranty
100756 Euchner
$74.90
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$74.90
$74.90 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 100756 with other products
Weight
Assured operating distance Sao
In compliance with
Switching voltage according to UL
Assured release distance Sar
Switching characteristics
Repeat accuracy R
Tightening torque
Switching voltage
Rated insulation voltage Ui
Method of operation
Connection
Switching current
Number of NO contacts
Rated impulse withstand voltage Uimp
Degree of protection
Mechanical life
Installation orientation
Shock and vibration resistance
Ambient temperature
Weight
Housing material
Design
Series
Product Class
Switching hysteresis
Assured operating distance Sao
Assured release distance Sar
PFHD
Operating distance
Mission time
Performance Level
Category
For the approval acc. to UL the following applies
Repeat accuracy R
Discrepancy time
Off-state current Ir
Utilization category acc. to EN 60947-5-2
Rated conditional short-circuit current
Test pulses
Test-pulse interval
Output voltage
Switching current
Turn-on time
Risk time according to EN 60947-5-3
Type of output
Fusing
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Degree of contamination (external, according to EN 60947-1)
Safety class
EMC protection requirements
Extension of risk time according to EN 60947-5-3 per device
Tightening torque
Current consumption
Installation orientation
Mounting distance
Operating voltage DC
Connection
Switching frequency
Ready delay
Cable ambient temperature (dynamic)
Degree of protection
Mounting method
Static bending radius
Weight
Shock and vibration resistance
Cable ambient temperature (static)
Housing material
Dynamic bending radius
Assured operating distance Sao
Switching hysteresis
Assured release distance Sar
Operating distance
Mission time
PFHD
For the approval acc. to UL the following applies
Additional feature
Performance Level
Repeat accuracy R
Category
Discrepancy time
Off-state current Ir
Rated conditional short-circuit current
Test-pulse interval
Utilization category acc. to EN 60947-5-2
Test pulses
Switching current
Output voltage
Type of output
Turn-on time
Risk time according to EN 60947-5-3
Safety class
EMC protection requirements
Degree of contamination (external, according to EN 60947-1)
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Fusing
Operating voltage DC
Switching frequency
Extension of risk time according to EN 60947-5-3 per device
Current consumption
Connection
Ready delay
Tightening torque
Installation orientation
Mounting method
Shock and vibration resistance
Mounting distance
Cable ambient temperature (static)
Cable ambient temperature (dynamic)
Degree of protection
Dynamic bending radius
Material
Housing material
Static bending radius
Weight
Selected product
Weight0.090405 lb
Assured operating distance Saomin.6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
In compliance withEN ISO 13849-1:2015; EN 50178:1997; EN 60204-1:2006/A1:2009; EN ISO 14119:2013; EN 61000-6-2:2005; EN 61000-6-3:2007/A1:2011; EN 60947-5-3:2013
Switching voltage according to ULmax.24 V DC
Assured release distance Sarmax.17 mm (The assured switch-off distance s_ar corresponds to the reset distance.)
Switching characteristicsIn series
Repeat accuracy Rmax.10 %
Tightening torque0,4 ... 0,5 Nm
Switching voltage24 V (DC)
Rated insulation voltage Ui26,4 V
Method of operationMagnetic, reed contact
Connection4-pin M8 plug connector
Switching current8 ... 500 mA
Number of NO contacts3 NO contact
Rated impulse withstand voltage Uimp1,5 kV
Degree of protectionIP67
Mechanical life100 x 10⁶
Installation orientationAny, pay attention to marking (During mounting it is to be ensured the marking arrows on actuator and read head are opposite each other.)
Shock and vibration resistanceIn acc. with EN 60947-5-3
Ambient temperature-20 ... 60 °C
Weight0,02 kg
Housing materialFiber glass reinforced PPS
DesignB
Series-
Product Class-
Switching hysteresis-
Assured operating distance Sao-
Assured release distance Sar-
PFHD-
Operating distance-
Mission time-
Performance Level-
Category-
For the approval acc. to UL the following applies-
Repeat accuracy R-
Discrepancy time-
Off-state current Ir-
Utilization category acc. to EN 60947-5-2-
Rated conditional short-circuit current-
Test pulses-
Test-pulse interval-
Output voltage-
Switching current-
Turn-on time-
Risk time according to EN 60947-5-3-
Type of output-
Fusing-
Rated impulse withstand voltage Uimp-
Rated insulation voltage Ui-
Degree of contamination (external, according to EN 60947-1)-
Safety class-
EMC protection requirements-
Extension of risk time according to EN 60947-5-3 per device-
Tightening torque-
Current consumption-
Installation orientation-
Mounting distance-
Operating voltage DC-
Connection-
Switching frequency-
Ready delay-
Cable ambient temperature (dynamic)-
Degree of protection-
Mounting method-
Static bending radius-
Weight-
Shock and vibration resistance-
Cable ambient temperature (static)-
Housing material-
Dynamic bending radius-
Assured operating distance Sao-
Switching hysteresis-
Assured release distance Sar-
Operating distance-
Mission time-
PFHD-
For the approval acc. to UL the following applies-
Additional feature-
Performance Level-
Repeat accuracy R-
Category-
Discrepancy time-
Off-state current Ir-
Rated conditional short-circuit current-
Test-pulse interval-
Utilization category acc. to EN 60947-5-2-
Test pulses-
Switching current-
Output voltage-
Type of output-
Turn-on time-
Risk time according to EN 60947-5-3-
Safety class-
EMC protection requirements-
Degree of contamination (external, according to EN 60947-1)-
Rated impulse withstand voltage Uimp-
Rated insulation voltage Ui-
Fusing-
Operating voltage DC-
Switching frequency-
Extension of risk time according to EN 60947-5-3 per device-
Current consumption-
Connection-
Ready delay-
Tightening torque-
Installation orientation-
Mounting method-
Shock and vibration resistance-
Mounting distance-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-
Degree of protection-
Dynamic bending radius-
Material-
Housing material-
Static bending radius-
Weight-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 100756?
The price of 100756 on MQ Automation is $74.90. Order now.
Out if stock but available for backorder.
100756 Euchner - READ HEAD
Similar products from: Safety Proximity Sensors
What can I help you find today?